Pablo Kraemer Fernandez

Mr. Pablo Kraemer Fernandez

Department of Prosthodontics, University Hospital Tuebingen, Osianderstrasse 2-8, 72076 Tübingen, Germany
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
AUAlexey Unkovskiy
Alexey Unkovskiy
FSFranziska Schmidt
Franziska Schmidt
FBFlorian Beuer
Florian Beuer
Ping LiPing Li
Ping Li
SSSebastian Spintzyk
Sebastian Spintzyk
PFPablo Kraemer Fernandez
Pablo Kraemer Fernandez
The topical literature lacks any comparison between stereolithography (SLA) and direct light processing (DLP) printing methods with regard to the accuracy of complete denture base fabrication, thereby utilizing materials certified for this purpose. In order to investigate this aspect, 15 denture bases were printed with SLA and DLP methods using three build angles: 0°, 45° and 90°. The dentures were digitalized using a laboratory scanner (D2000, 3Shape) and analyzed in analyzing software (Geomagic Control X, 3D systems). Differences between 3D datasets were measured using the root mean square (RMS) value for trueness and precision and mean and maximum deviations were obtained for each denture base. The data were statistically analyzed using two-way ANOVA and Tukey’s multiple comparison test. A heat map was generated to display the locations of the deviations within the intaglio surface. The overall tendency indicated that SLA denture bases had significantly higher trueness for most build angles compared to DLP (p < 0.001). The 90° build angle may provide the best trueness for both SLA and DLP. With regard to precision, statistically significant differences were found in the build angles only. Higher precision was revealed in the DLP angle of 0° in comparison to the 45° and 90° angles.

24 July 2020 in Materials
Verified
Journal Article
Open access
PDF file
PFPablo Kraemer Fernandez
Pablo Kraemer Fernandez
AUAlexey Unkovskiy
Alexey Unkovskiy
VBViola Benkendorff
Viola Benkendorff
AKAndrea Klink
Andrea Klink
SSSebastian Spintzyk
Sebastian Spintzyk
(1) Background: To date, no information on the polishability of milled and 3D-printed complete denture bases has been provided, which is relevant in terms of plaque accumulation. (2) Methods: three groups (n = 30) were manufactured using the cold-polymerization polymethilmethacrilate, milling (SM) and 3D printing (AM). 10 specimens of each group were left untreated (reference). 10 more specimens were pre-polished (intermediate polishing) and 10 final specimens were highgloss polished. An additional 20 specimens were 3D printed and coated with the liquid resin (coated), 10 of which were additionally polished (coated + polished). For each group Ra and Rz values, gloss value and REM images were obtained. (3). The “highgloss-polished” specimens showed statistically lower Ra and Rz values in the SM, followed by AM and conventional groups. In the AM group statistically lower surfaces roughness was revealed for highgloss-polished, “coated + polished”, and “coated” specimens, respectively. (4) Conclusions: The milled specimens demonstrated superiors surface characteristics than 3D printed and conventionally produced after polishing. The polished specimens demonstrated superior surface characteristics over coated specimens. However, the surface roughness by both polished and coated specimens was within the clinically relevant threshold of 0.2 µm.

1 February 2021 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
Ping LiPing Li
Ping Li
PFPablo Kraemer Fernandez
Pablo Kraemer Fernandez
AKAndrea Klink
Andrea Klink
YXYichen Xu
Yichen Xu
SSSebastian Spintzyk
Sebastian Spintzyk

1 January 2022 in Journal of Dentistry
Verified
Journal Article
Closed access
Ping LiPing Li
Ping Li
PFPablo Kraemer Fernandez
Pablo Kraemer Fernandez
SSSebastian Spintzyk
Sebastian Spintzyk
FSFranziska Schmidt
Franziska Schmidt
FBFlorian Beuer
Florian Beuer
AUAlexey Unkovskiy
Alexey Unkovskiy

1 March 2020 in NeuroImage
Verified
Journal Article
Open access
JBJonas Bause
Jonas Bause
JPJonathan R. Polimeni
Jonathan R. Polimeni
JSJohannes Stelzer
Johannes Stelzer
MIMyung-Ho In
Myung-Ho In
PEPhilipp Ehses
Philipp Ehses
KSKlaus Scheffler
Klaus Scheffler
Functional imaging with sub-millimeter spatial resolution is a basic requirement for assessing functional MRI (fMRI) responses across different cortical depths and is used extensively in the emerging field of laminar fMRI. Such studies seek to investigate the detailed functional organization of the brain and may develop to a new powerful tool for human neuroscience. However, several studies have shown that measurement of laminar fMRI responses can be biased by the image acquisition and data processing strategies. In this work, measurements with three different gradient-echo EPI BOLD fMRI protocols with a voxel size down to 650 ​μm isotropic were performed at 9.4 ​T. We estimated how prospective motion correction can help to improve spatial accuracy by reducing the number of spatial resampling steps in postprocessing. In addition, we demonstrate key requirements for accurate geometric distortion correction to ensure that distortion correction maps are properly aligned to the functional data and that strong variations of distortions near large veins can lead to signal overlays which cannot be corrected for during postprocessing. Furthermore, this study illustrates the spatial extent of bias induced by pial and other larger veins in laminar BOLD experiments. Since these issues under investigation affect studies performed with more conventional spatial resolutions, the methods applied in this work may also help to improve the understanding of the BOLD signal more broadly.

AUAlexey Unkovskiy
Alexey Unkovskiy
Fabian HuettigFabian Huettig
Fabian Huettig
PFPablo Kraemer Fernandez
Pablo Kraemer Fernandez
SSSebastian Spintzyk
Sebastian Spintzyk
A multilayer mouth guard is known to have the best protective performance. However, its manufacturing in a digital workflow may be challenging with regards to virtual design and materialization. The present case demonstrates a pathway to fabricate a multilayer individualized mouth guard in a fully digital workflow, which starts with intraoral scanning. A free-form CAD software was used for the virtual design. Two various CAM techniques were used, including Polyjet 3D printing of rubber-like soft material and silicone printing using Drop-on-Demand technique. For both methods the outer layer was manufactured from more rigid materials to facilitate its protective function; the inner layer was printed from a softer material to aid a better adaptation to mucosa and teeth. Both 3D printed multilayer mouth guards showed a clinically acceptable fit and were met with patient appraisal. Their protective capacities must be evaluated in further clinical studies.