Electric vehicles (EVs) are popular now due to zero carbon emissions. Hence, with the advancement of EVs, charging station (CS) design also plays a vital role. CS is generally called a charge or power supply point and delivers power to the EVs. Usually, CSs are either of the direct current (DC) type, as the EVs need a DC supply or in some cases of the alternating current (AC) type, as the traditional power grid delivers AC power. Usually, on-board chargers (on-BCs) and off-board chargers (off-BCs) are used to charge the EV batteries. Due to heavy loads, size, and budget constraints, many on-BC facilities have power limits, which can be overcome by designing the on-BC with an electrical motor. In different types of off- and on-BCs, the power flow can be in one or two directions. Uni-directional power flow reduces hardware needs and makes connecting problems easier, whereas bi-directional power flow allows battery energy to be injected back into the grid. The primary issue with EVs is the charging time as well as the need for charging infrastructure. The infrastructure for fast charging makes on-board energy storage less expensive and more essential. This paper details various charging technologies, including wired and wireless methods. Also, numerous on-board and off-board charging topologies are summarized in the literature. Different EV battery charging standards and levels are also discussed. The paper also delineates several alternative CS topologies based on architecture, energy storage, and renewable energy sources. Considering the present scenario, having a sophisticated quick EV charging network is crucial to ensure maximum EV charging with renewable power and reduce grid strain.
Leading to the enhancement of smart grid implementation, the peer-to-peer (P2P) energy transaction concept has grown dramatically in recent years allowing the end-users to successfully exchange their excess generation and demand in a more profitable way. This paper presents local energy market (LEM) architecture with various market strategies for P2P energy trading among a set of end-users (consumers and prosumers) in a smart residential locality. In a P2P fashion, prosumers/consumers can export/import the available generation/demand in the LEM at a profit relative to utility prices. A common portal known as the transactive energy market operator (TEMO) is introduced to manage the trading in the LEM. The goal of the TEMO is to develop a transaction agreement among P2P players by establishing a price for each transaction based on the price and trading demand provided by the participants. A few case studies on a location with ten residential P2P participants validate the performance of the proposed TEMO.
Electric vehicles (EVs) are emerging as an alternative transportation system owing to a reduction in depleting lubricates usage and greenhouse gas emissions. This paper presents a technical review of each and every sub-system and its feasible control of battery EV (BEV) propulsion units. The study includes the possible combination of electrical machines (EMs), storage system, and power electronic converters and their associated control strategies. The primary unit, i.e., EM, is the heart of the EV, which is used to drive the vehicle at the desired speed as well as to restore the regenerative braking (RB) energy that is generated to enhance the overall system reliability. To electrify the transportation sector, it is necessary to include new options of power electronic converter topologies and their associated control strategies for numerous reasons, which include extracting maximum power from sources in case the EV is powered from renewable energy resources, boosting the energy storage capability for longer electric range, managing power flow from the source to battery or battery to vehicle or vehicle to battery, and regulating the speed of the vehicle and braking control. Based on the survey, the suitable combination of sub-systems and their control for three and four-wheeler EVs are summarized in this paper.
13 September 2017 in IEEE Transactions on Sustainable Energy
This paper emphasises the development of a simplified active power control scheme for enhanced operation of grid integrated permanent magnet synchronous generator (PMSG) based wind-driven generators (WGs). An active power reference generation scheme is proposed for the machine side converter (MSC) to inject active power into the grid even under grid disturbances, without violating system components rating. In this scheme, the controller employed for MSC adjusts the active power captured proportionate to the drop in the grid voltage upon considering wind speed and rotor speed. Furthermore, unlike dual vector control scheme, the grid side converter (GSC) controller is implemented in a positive synchronous frame (PSF) with the proposed current oscillation cancellation scheme to suppress the oscillations in dc-link voltage, active and reactive power of the grid and to obtain symmetrical sinusoidal grid current. Extensive analytical simulation has been carried out in PSCAD/ EMTDC to validate the superiority of proposed control scheme over the conventional schemes when WG is subjected to various grid disturbances. The reduced percentage of oscillation in the system parameters such as dc-link voltage and grid active power confirms the efficacy of the proposed method when compared with the conventional control techniques.
Permanent magnet synchronous machine (PMSM) has proven to be a more economical traction drive system for electric vehicle (EV) applications owing to increased efficiency and high-power density. However, the drive system requires more efficient control schemes to deliver better dynamic performance irrespective of dynamic changes in the motor speed, machine parameters and disturbances. Hence, to tackle the dynamic changes, to enhance the wider operating speed, to achieve precise speed tracking capability, and improved efficiency, a novel control algorithm for the PMSM based EV is proposed in this paper. The control algorithm is implemented by adopting the merits of conventional proportional resonance (PR) and proportional integral (PI) controller. The proposed control strategy is designed with an outer PI speed regulator and the inner enhanced PR (EPR) current regulator. The uniqueness of the proposed EPR controller is that the controller is designed to damp the torsional mode oscillation owing to dynamic changes such as speed and torque regulation evading the additional control loop. The effectiveness of the control scheme is tested in MATLAB Simulink and hardware-in-loop (HIL) real time simulator RT5700. To validate the effectiveness of the proposed control scheme the results are compared with the conventional control schemes. The results presented show that the proposed control technique successfully enhances the static and dynamic performance, and resilience of the EV system. Also, the proposed scheme significantly reduces the flux ripples, torque ripples, current jitter, peak overshoot, undershoot compared to the conventional current controllers.
The use of permanent magnet synchronous machine (PMSM) in vehicle propulsion systems is growing in prominence. The machines provide greater torque density and efficiency as a result of PMSM pre-excitation. However, because of their poor torsional vibration dampening, their intrinsic torque ripple may provide a challenge for electric vehicles (EVs) and degrade passenger comfort. This may prohibit the utilization of PMSM to increase the energy economy of vehicles. This paper proposed a speed-current adaptive proportional-integral-resonant (PIR) control strategy to reduce periodic torque harmonics and provide smooth speed control of the PMSM drive system. The effects of several non-ideal components on speed and current components are analyzed according to their location in the system. The components include rotor flux harmonics, cogging torque, inaccurate current measurement including offset error and scaling error, and inverter dead time error, these components all lead to periodic torque harmonics. In order to determine the best phase adjustment parameters for the resonant item to minimize speed-torque harmonics and ensure system stability, stability analysis is carried out to take into account the delays brought on by the current loop and speed loop. Consequently, the PMSM drive system’s stability, overall performance, and efficiency are enhanced due to the decreased harmonics in the speed and current loop. Ultimately, the findings of the simulation and real-time simulator utilizing the OPAL-RT OP5700 platform show that the proposed adaptive PIR control method successfully lowers the periodic speed-current harmonics THD values of the PMSM drive when compared to conventional control strategies. The proposed control system is more stable and efficient as a result of lower THD values.