Soumya Ranjan Das

Dr. Soumya Ranjan Das

Electrical, International Institute of Information Technology, Bhubaneswar, India
orcid
Manipal Academy of Higher Education

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 April 2020 in IEEE Access
Verified
Journal Article
Open access
AMAlok Kumar Mishra
Alok Kumar Mishra
Soumya Ranjan DasSoumya Ranjan Das
Soumya Ranjan Das
PRPrakash K. Ray
Prakash K. Ray
RMRanjan Kumar Mallick
Ranjan Kumar Mallick
AMAsit Mohanty
Asit Mohanty
DMDillip K. Mishra
Dillip K. Mishra
This paper presents a Hybrid Shunt Active Power Filter (HSAPF) optimized by hybrid Particle Swarm Optimization-Grey Wolf Optimization (PSO-GWO) and Fractional Order Proportional-Integral-Derivative Controller (FOPIDC) for reactive power and harmonic compensation under balance and unbalance loading conditions. Here, the parameters of FOPID controller are tuned by PSO-GWO technique to mitigate the harmonics. Comparing Passive with Active Filters, the former is tested to be bulky and design is complex and the later is not cost effective for high rating. Hence, a hybrid structure of shunt active and passive filter is designed using MATLAB/Simulink and in real time experimental set up. The compensation process for shunt active filter is different from predictable methods such as (p-q) or (id-iq) theory, in which only the source current is to be sensed. The performance of the proposed controller is tested under different operating conditions such as steady and transient states and indices like Total Harmonic Distortion (THD), Input Power Factor (IPF), Real Power (P) and Reactive Power (Q) are estimated and compared with that of other controllers. The parameters of FOPIDC and Conventional PID Controller (CPIDC) are optimized by the techniques such as PSO, GWO and hybrid PSOGWO. The comparative simulation/experiment results reflect the better performance of PSO-GWO optimized FOPIDC based HSAPF with respect to PSO/GWO optimized FOPIDC/CPIDC based HSAPF under different operating conditions.

29 July 2021 in Energies
Verified
Journal Article
Open access
PDF file
Soumya Ranjan DasSoumya Ranjan Das
Soumya Ranjan Das
PRPrakash Ray
Prakash Ray
ASArun Kumar Sahoo
Arun Kumar Sahoo
SRSomula Ramasubbareddy
Somula Ramasubbareddy
THANIKANTI SUDHAKAR BABUTHANIKANTI SUDHAKAR BABU
THANIKANTI SUDHAKAR BABU
Lucian MihetLucian Mihet
Lucian Mihet
Power quality (PQ) has become an important topic in today’s power system scenario. PQ issues are raised not only in normal three-phase systems but also with the incorporation of different distributed generations (DGs), including renewable energy sources, storage systems, and other systems like diesel generators, fuel cells, etc. The prevalence of these issues comes from the non-linear features and rapid changing of power electronics devices, such as switch-mode converters for adjustable speed drives and diode or thyristor rectifiers. The wide use of these fast switching devices in the utility system leads to an increase in disturbances associated with harmonics and reactive power. The occurrence of PQ disturbances in turn creates several unwanted effects on the utility system. Therefore, many researchers are working on the enhancement of PQ using different custom power devices (CPDs). In this work, the authors highlight the significance of the PQ in the utility network, its effect, and its solution, using different CPDs, such as passive, active, and hybrid filters. Further, the authors point out several compensation strategies, including reference signal generation and gating signal strategies. In addition, this paper also presents the role of the active power filter (APF) in different DG systems. Some technical and economic considerations and future developments are also discussed in this literature. For easy reference, a volume of journals of more than 140 publications on this particular subject is reported. The effectiveness of this research work will boost researchers’ ability to select proper control methodology and compensation strategy for various applications of APFs for improving PQ.

23 May 2020 in Neural Computing and Applications
Verified
Journal Article
Closed access
PDF file
AMAlok K. Mishra
Alok K. Mishra
PRPrakash K. Ray
Prakash K. Ray
RMRanjan K. Mallick
Ranjan K. Mallick
AMAsit Mohanty
Asit Mohanty
Soumya Ranjan DasSoumya Ranjan Das
Soumya Ranjan Das

9 November 2018 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
PRPrakash K. Ray
Prakash K. Ray
Soumya Ranjan DasSoumya Ranjan Das
Soumya Ranjan Das
AMA. Mohanty
A. Mohanty
In this paper, a three-phase Series Hybrid Active Filter (SEHAF) interconnected with Photovoltaic (PV) system and DC-DC boost converter is proposed to minimize sag, swell and harmonics caused due to non-linear power electronic loads. The SEHAF consists of a Voltage Source Inverter (VSI) where, a capacitor is connected across it providing consistency in managing and compensating the reactive power. This minimizes the sag, swell and harmonics present in the source and load voltages. With the integration of PV, the voltage across the dc link capacitor of VSI is controlled effectively which helps in better compensation. The reference current generation is done using the proposed Robust Extended Complex Kalman Filter (RECKF) technique. The performance of HAF integrated with PV is analyzed using Synchronous Reference Frame (SRF) with PI as well as Fuzzy Logic Controller (FLC) and is compared with the proposed RECKF technique. The PV integrated hybrid power system is developed using MATLAB/SIMULINK. Further, real-time digital simulation using OPAL-RT OP5142 is also carried out to support the simulation results. It is analyzed that the proposed control scheme provides better harmonics compensation as compared to the conventional PI and FLC.

20 September 2022 in International Journal of Fuzzy Systems
Verified
Journal Article
Closed access
PDF file
AMAlok Kumar Mishra
Alok Kumar Mishra
PNPradip Kumar Nanda
Pradip Kumar Nanda
PRPrakash Kumar Ray
Prakash Kumar Ray
Soumya Ranjan DasSoumya Ranjan Das
Soumya Ranjan Das
APAkshaya Kumar Patra
Akshaya Kumar Patra

21 November 2022 in Electronics
Verified
Journal Article
Open access
PDF file
Soumya Ranjan DasSoumya Ranjan Das
Soumya Ranjan Das
AMAlok Kumar Mishra
Alok Kumar Mishra
PRPrakash Kumar Ray
Prakash Kumar Ray
Surender Reddy SalkutiSurender Reddy Salkuti
Surender Reddy Salkuti
SKSeong-Cheol Kim
Seong-Cheol Kim
The hybrid AC-DC microgrid (MG) has gained popularity recently as it offers the benefits of AC and DC systems. Interconnecting AC-DC converters are necessary since the MG has both DC and AC sub-grids. Adding an extra harmonic adjustment mechanism to the interlinking converters is promising because non-linear AC loads can worsen the quality of the voltage on the AC bus. The interlinking converters’ primary function is to interchange real and reactive power between DC and AC sub-grids, so the typical harmonic controlling approach implemented for active power filters (APFs) might not be appropriate for them. When the MG’s capacity is high, it is desirable that the switching frequency be lesser than the APFs. The performance of harmonic correction or even system stability may suffer at low switching frequencies. In this study, a harmonic compensating technique appropriate for hybrid AC-DC interlinking converters with lower switching frequencies is planned. The suggested strategy, modeling techniques, stability analysis, and a thorough virtual impedance design are discussed in this work.