Objective: Tinnitus Handicap Inventory (THI) is one of the world’s most commonly used tools to assess tinnitus severity. The aim of the current study was to establish a revised THI grading system using standard Z-scores and percentiles. Design: Cross-sectional observational study. Study sample: Adult patients (1042 participants – 518 (49.7%) female and 524 (50.3%) male) reporting tinnitus duration of a minimum of 6 months with complete documentation on patient’s clinical status (age, gender, tinnitus duration and laterality, tinnitus handicap based on THI and hearing status based on pure-tone audiometry) were included in the study. Results: Multivariate analysis of variance was used to analyse the effects of gender and hearing loss on THI scores and revealed there was a significant effect of both. Consequently, separate grading systems for women and men, as well as for subjects with normal hearing and hearing loss, is proposed. Conclusions: Our findings are generally consistent with existing grading. Normative values proposed for THI scores, based on a large group of tinnitus patients, could be useful to guide decisions about appropriate intervention options or to evaluate treatment outcomes.
30 March 2021 in European Archives of Oto-Rhino-Laryngology
Background: The World Health Organization reports that the number of tinnitus sufferers is increasing year on year. Given the common use of mobile devices and the availability of applications designed to support patients in tinnitus therapy and reduce tinnitus severity, patients seeking help are likely to try this form of support. The aim of this study was to evaluate the effectiveness of a mobile application in tinnitus sound therapy, in this case ReSound Tinnitus Relief™. Methods: The study involved 52 patients hospitalized for tinnitus. All participants used the free ReSound Tinnitus Relief application for 6 months. The application is based on sound therapy. Patients were advised to use the application for at least 30 min per day, the sounds should not completely mask the tinnitus, and they should be listened to via a loudspeaker. The effects of the therapy were evaluated by means of standardized questionnaires for tinnitus severity: the Tinnitus Handicap Inventory and the Tinnitus Functional Index. Results: The study showed a reduction in tinnitus severity as measured by both questionnaires. The general severity decreased after the first 3 months and again in the following 3 months of using the application. In both questionnaires the biggest changes were observed in the subscales of emotions. Conclusions: Results obtained here from standardized questionnaires indicate that the tested application may contribute to tinnitus reduction. However, it is advisable to conduct further research on the applicability of such technology in medical practice.
The primary objectives of this study were to evaluate the effect of hearing implant (HI) use on quality of life (QoL) and to determine which QoL measure(s) quantify QoL with greater sensitivity in users of different types of HIs. Participants were adult cochlear implant (CI), active middle ear implant (VIBRANT SOUNDBRIDGE (VSB)), or active transcutaneous bone conduction implant (the BONEBRIDGE (BB)) recipients. Generic QoL and disease-specific QoL were assessed at three intervals: pre-activation, 6 months of device use, and 12 months of device use. 169 participants completed the study (110 CI, 18VSB, and 41BB). CI users’ QoL significantly increased from 0–6 m device use on both the generic- and the disease-specific measures. On some device-specific measures, their QoL also significantly increased between 6 and 12 m device use. VSB users’ QoL significantly increased between all tested intervals with the disease-specific measure but not the generic measure. BB users’ QoL significantly increased from 0–6 m device use on both the generic- and the disease-specific measures. In sum, HI users experienced significant postoperative increases in QoL within their first 12 m of device use, especially when disease-specific measures were used. Disease-specific QoL measures appeared to be more sensitive than their generic counterparts.
7 August 2021 in European Archives of Oto-Rhino-Laryngology
Purpose: In most cases, tinnitus co-exists with hearing loss, suggesting that poorer speech understanding is simply due to a lack of acoustic information reaching the central nervous system (CNS). However, it also happens that patients with tinnitus who have normal hearing also report problems with speech understanding, and it is possible to suppose that tinnitus is to blame for difficulties in perceptual processing of auditory information. The purpose of the study was to evaluate the auditory processing abilities of normally hearing subjects with and without tinnitus. Methods: The study group comprised 97 adults, 54 of whom had normal hearing and chronic tinnitus (the study group) and 43 who had normal hearing and no tinnitus (the control group). The audiological assessment comprised pure-tone audiometry and high-frequency pure-tone audiometry, impedance audiometry, and distortion product oto-acoustic emission assessment. To evaluate possible auditory processing deficits, the Frequency Pattern Test (FPT), Duration Pattern Test (DPT), Dichotic Listening Test (DLT), and Gap Detection Threshold (GDT) tests were performed. Results: The tinnitus subjects had significantly lower scores than the controls in the gap detection test (p < 0.01) and in the dichotic listening test (p < 0.001), but only for the right ear. The results for both groups were similar in the temporal ordering tests (FPT and DPT). Right-ear advantage (REA) was found for the controls, but not for the tinnitus subjects. Conclusion: In normally hearing patients, the presence of tinnitus may be accompanied with auditory processing difficulties.
(1) Background: Decreased sound tolerance is a significant problem in tinnitus sufferers. The aim of the study was to evaluate the relationship between tinnitus and decreased sound tolerance (hyperacusis and misophonia). (2) Methods: The study sample consisted of 74 patients with tinnitus and decreased sound tolerance. The procedure comprised patient interviews, pure tone audiometry, impedance audiometry, measurement of uncomfortable loudness levels, and administration of the Hyperacusis Questionnaire, Tinnitus Handicap Inventory, and Visual Analogue Scales. (3) Results: The majority (69%) of the patients reported that noise aggravated their tinnitus. The correlation between tinnitus and hyperacusis was found to be statistically significant and positive: r = 0.44; p < 0.01. The higher the tinnitus severity, the greater the hyperacusis. There was no correlation between misophonia and hyperacusis (r = 0.18; p > 0.05), or between misophonia and tinnitus (r = 0.06; p > 0.05). (4) Conclusions: For tinnitus patients the more significant problem was hyperacusis rather than misophonia. The diagnosis and treatment of decreased sound tolerance should take into account not only audiological, but also psychological problems of the patients.
17 February 2023 in International Journal of Audiology
The aim of this interventional non-randomised prospective controlled study was to assess the effectiveness of transcutaneous vagus nerve stimulation (tVNS) in human subjects with tinnitus.The Paras...