Edwin Ruales Ruales

Dr. Edwin Ruales Ruales

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 July 2022 in Periodontology 2000
Verified
Journal Article
Open access
MRMario Romandini
Mario Romandini
EREdwin Ruales Ruales
Edwin Ruales Ruales
SSSofya Sadilina
Sofya Sadilina
CHChristoph H. F. Hämmerle
Christoph H. F. Hämmerle
MSMariano Sanz
Mariano Sanz
Flapless and fully guided implant placement has the potential to maximize efficacy outcomes and at the same time to minimize surgical invasiveness. The aim of the current systematic review was to answer the following PICO question: “In adult human subjects undergoing dental implant placement (P), is minimally invasive flapless computer‐aided fully guided (either dynamic or static computer‐aided implant placement (sCAIP)) (I) superior to flapped conventional (free‐handed implant placement (FHIP) or cast‐based/drill partially guided implant placement (dPGIP)) surgery (C), in terms of efficacy, patient morbidity, long‐term prognosis, and costs (O)?” Randomized clinical trials (RCTs) fulfilling specific inclusion criteria established to answer the PICO question were included. Two review authors independently searched for eligible studies, screened the titles and abstracts, performed full‐text analysis, extracted the data from the published reports, and performed the risk of bias assessment. In cases of disagreement, a third review author took the final decision during ad hoc consensus meetings. The study results were summarized using random effects meta‐analyses, which were based (wherever possible) on individual patient data (IPD). A total of 10 manuscripts reporting on five RCTs, involving a total of 124 participants and 449 implants, and comparing flapless sCAIP with flapped FHIP/cast‐based partially guided implant placement (cPGIP), were included. There was no RCT analyzing flapless dynamic computer‐aided implant placement (dCAIP) or flapped dPGIP. Intergroup meta‐analyses indicated less depth deviation (difference in means (MD) = −0.28 mm; 95% confidence interval (CI): −0.59 to 0.03; moderate certainty), angular deviation (MD = −3.88 degrees; 95% CI: −7.00 to −0.77; high certainty), coronal (MD = −0.6 mm; 95% CI: −1.21 to 0.01; low certainty) and apical (MD = −0.75 mm; 95% CI: −1.43 to −0.07; moderate certainty) three‐dimensional bodily deviations, postoperative pain (MD = −17.09 mm on the visual analogue scale (VAS); 95% CI: −33.38 to −0.80; low certainty), postoperative swelling (MD = −6.59 mm on the VAS; 95% CI: −19.03 to 5.85; very low certainty), intraoperative discomfort (MD = −9.36 mm on the VAS; 95% CI: −17.10 to −1.61) and surgery duration (MD = −24.28 minutes; 95% CI: −28.62 to −19.95) in flapless sCAIP than in flapped FHIP/cPGIP. Despite being more accurate than flapped FHIP/cPGIP, flapless sCAIP still resulted in deviations with respect to the planned position (intragroup meta‐analytic means: 0.76 mm in depth, 2.57 degrees in angular, 1.43 mm in coronal, and 1.68 in apical three‐dimensional bodily position). Moreover, flapless sCAIP presented a 12% group‐specific intraoperative complication rate, resulting in an inability to place the implant with this protocol in 7% of cases. Evidence regarding more clinically relevant outcomes of efficacy (implant survival and success, prosthetically and biologically correct positioning), long‐term prognosis, and costs, is currently scarce. When the objective is to guarantee minimal invasiveness at implant placement, clinicians could consider the use of flapless sCAIP. A proper case selection and consideration of a safety margin are, however, suggested.

3 July 2019 in Journal of Esthetic and Restorative Dentistry
Verified
Journal Article
Closed access
PDF file
EREdwin Ruales Ruales
Edwin Ruales Ruales
PPPatrícia Pauletto
Patrícia Pauletto
KAKarin Apaza-Bedoya
Karin Apaza-Bedoya
CVClaudia A. M. Volpato
Claudia A. M. Volpato
Mutlu ÖzcanMutlu Özcan
Mutlu Özcan
Cesar Augusto BenfattiCesar Augusto Benfatti
Cesar Augusto Benfatti

17 May 2019 in Journal of Esthetic and Restorative Dentistry
Verified
Journal Article
Closed access
PDF file
EREdwin Ruales Ruales
Edwin Ruales Ruales
Paulo Francısco CesarPaulo Francısco Cesar
Paulo Francısco Cesar
Bruno HenriquesBruno Henriques
Bruno Henriques
MFMarcio C. Fredel
Marcio C. Fredel
Mutlu ÖzcanMutlu Özcan
Mutlu Özcan
CVClaudia A. M. Volpato
Claudia A. M. Volpato

1 December 2018 in Journal of Oral Implantology
Verified
Journal Article
Closed access
CLCamilo Andres Villabona Lopez
Camilo Andres Villabona Lopez
MVMarco Antônio Amorin Vasco
Marco Antônio Amorin Vasco
EREdwin Ruales Ruales
Edwin Ruales Ruales
KAKarin Apaza-Bedoya
Karin Apaza-Bedoya
CBCesar Magalhaes Benfatti
Cesar Magalhaes Benfatti
TDTatiana Deliberador
Tatiana Deliberador
Zirconia has been presented as an alternative biomaterial to titanium, commercially presented as a single-body implant and/or as an abutment, demonstrating clinically biocompatible favorable results in white and rose esthetics. However, the number of long-term in vivo studies and mechanical tests evaluating the response of stress distribution compared with titanium implants is still limited. The aim of the study was to compare the principal peak stresses in the peri-implant bone around titanium and zirconia implants using the finite element method. Four groups of 3-dimensional models were constructed for the tests: G1, external hexagon titanium implant with a zirconia abutment; G2, zirconia implant with a zirconia abutment; G3, single-body titanium implant; and G4, single-body zirconia implant. Axial and oblique loads of 100 N at 45° were simulated in the prosthetic crown. The bone results showed that the peak stresses decreased by 12% in zirconia implants with 2 parts for axial load and 30% for the oblique load. In single-body implants, the peak stresses decreased 12% in the axial load and 34% in the oblique load when a zirconia implant was used compared with a titanium implant. Although the stress values in megapascals are similar, it can be concluded that the zirconia implants decrease the stress peaks at the peri-implant bone area around the implant platform when compared with titanium implants.

16 August 2021 in Clinical Oral Investigations
Verified
Journal Article
Closed access
PDF file
PPPatrícia Pauletto
Patrícia Pauletto
EREdwin Ruales Ruales
Edwin Ruales Ruales
LMLuis André Mezzomo
Luis André Mezzomo
CSCRISTINE MIRON STEFANI
CRISTINE MIRON STEFANI
Mario Taba JrMario Taba Jr
Mario Taba Jr
GCGraziela De Luca Canto
Graziela De Luca Canto

1 March 2022 in Open Ceramics
Verified
Journal Article
Open access
EREdwin Ruales Ruales
Edwin Ruales Ruales
MBMarcelo Dal Bó
Marcelo Dal Bó
WNWenceslau Fernandes das Neves
Wenceslau Fernandes das Neves
MFMárcio Celso Fredel
Márcio Celso Fredel
CVClaudia Angela Maziero Volpato
Claudia Angela Maziero Volpato
Dachamir HotzaDachamir Hotza
Dachamir Hotza