Yiujie Ma

Yiujie Ma


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2020 in Energies
Verified
Journal Article
Open access
PDF file
YMYoujie Ma
Youjie Ma
XZXuesong Zhou
Xuesong Zhou
YMYiujie Ma
Yiujie Ma
QLQian Liu
Qian Liu
YZYongliang Zhou
Yongliang Zhou
CYChangsheng Yuan
Changsheng Yuan
In wind power systems, LCL inverters have technical problems. First of all, they are non-linear systems and are no longer adapted to the superposition principle; secondly, the coupling is great; finally, it is easy to be interfered by the outside world, and the interference mainly comes from voltage fluctuations and nonlinear loads on the grid. Therefore, it is difficult to control the output result, and then the improved linear active disturbance rejection control (LADRC) is applied. The main improvement of the improved LADRC lies in the linear extended state observer (LESO). Introducing the total disturbance differential signal in LESO, and in order to improve the ability to suppress high-frequency noise, a series of first-order inertia link was applied. The analysis method in this article is mainly frequency domain analysis, under the condition of obtaining LADRC closed-loop transfer function and frequency band characteristics, theoretical analysis of LADRC tracking estimation ability, disturbance suppression ability, and stability. A large number of experimental simulation results verified the superiority of improving LADRC. The main manifestation is that the improved LADRC not only has a fast response speed but also has a strong ability to suppress disturbances and has a good noise suppression effect in high frequency bands.

15 October 2019 in Energies
Verified
Journal Article
Open access
PDF file
YMYiujie Ma
Yiujie Ma
MLMao Liu
Mao Liu
XZXuesong Zhou
Xuesong Zhou
YMYoujie Ma
Youjie Ma
FZFaqing Zhao
Faqing Zhao
The wind power grid-connected inverter system has nonlinear, strong coupling, and is susceptible to grid voltage fluctuations and nonlinear load effects. To achieve satisfactory control results, the voltage outer loop is controlled by an improved linear active disturbance rejection control (LADRC). LADRC has strong adaptability, robustness and operability. It can automatically detect and compensate for internal and external disturbances, and correct complex controlled objects to integrator series. The total perturbation differential signal is introduced in the traditional linear extended state observer (LESO), which improves the dynamic perturbation observation ability of LESO. The frequency response characteristics analysis shows that the new LADRC has better anti-interference performance. The effectiveness of the improved controller under multiple operating conditions is verified by simulation.

14 March 2020 in Energies
Verified
Journal Article
Open access
PDF file
BWBoning Wu
Boning Wu
XZXuesong Zhou
Xuesong Zhou
YMYiujie Ma
Yiujie Ma
The DC distribution network has more advantages in power transmission, grid connection of distributed energy, and reliability of power supply when compared with AC distribution network, but there are still many problems in the development of DC distribution network. DC bus voltage control is one of the hot issues in the research of DC distribution network. To solve this problem, in this paper, a new type of sliding mode active disturbance rejection control (SMADRC) controller for AC/DC converters is designed and applied to the voltage outer loop. The linear extended state observer (LESO) can observe the state variables and the total disturbance of the system. The SMADRC is composed of a sliding mode controller, LESO, and disturbance compensator, which can compensate the total disturbance observed by LESO properly. Therefore, it improves the dynamic. At the same time, it can also reduce the system jitter that is caused by sliding mode controller. The state variables that are observed by the LESO are used in the design of sliding mode controller, which greatly simplifies the design of sliding mode controller. Finally, the simulation results of Matlab/Simulink show that the controller has good start-up performance and strong robustness.

9 November 2019 in Energies
Verified
Journal Article
Open access
PDF file
YMYiujie Ma
Yiujie Ma
FZFaqing Zhao
Faqing Zhao
XZXuesong Zhou
Xuesong Zhou
MLMao Liu
Mao Liu
YMYoujie Ma
Youjie Ma
In order to improve the dynamic response speed and the steady-state performance of the DC side bus voltage of the wind power grid-connected inverter, a mathematical model of a typical three-phase voltage type PWM (Pulse Width Modulation, PWM) grid-connected inverter was established, and its traditional voltage-current double closed loop with proportional-integral control method was analyzed. Then a second-order linear active disturbance rejection controller that does not depend on system model information was designed to replace the traditional voltage outer loop proportional-integral controller, thus a new double closed-loop control structure was formed to control it. The frequency domain theory was used to analyze the convergence of the third-order linear extended state observer and the influence of the total disturbance on the performance of the third-order linear extended state observer. The parameter tuning scheme of the designed controller was given. Finally, the 1.5 MW direct-driven permanent magnet wind power generation system was built in the Matlab/Simulink software and the control effects of the two control modes under different working conditions are compared. The simulation results show that the control scheme designed in this paper is superior to the traditional proportional-integral controller which has good anti-interference characteristics and robustness. Especially it has a good stability effect on DC side bus voltage fluctuations.