Highly precise micromanipulation tools that can manipulate and interrogate cell organelles and components must be developed to support the rapid development of new cell-based medical therapies, thereby facilitating in-depth understanding of cell dynamics, cell component functions, and disease mechanisms. This paper presents a literature review on micro/nanomanipulation tools and their control methods for single-cell surgery. Micromanipulation methods specifically based on laser, microneedle, and untethered micro/nanotools are presented in detail. The limitations of these techniques are also discussed. The biological significance and clinical applications of single-cell surgery are also addressed in this paper.
25 May 2020 in IEEE/ASME Transactions on Mechatronics
Precise intracellular delivery is essential for many biomedical applications, such as genome editing and intracellular mechanism investigation. This paper presents the development of an automated intracellular delivery approach using a robot-aided microscope system with 3D reconstruction information. A series of optical section images are sampled by objective lens movement and restored on the computer. After several processes, including deconvolution, segmentation, and 3D reconstruction of sampled images, optimal delivery position can be acquired via geometry analysis based on the proposed volume-based model. Guided by this 3D information, a robust controller that can compensate for external disturbances is utilized to manipulate micropipettes to deliver exogenous materials into single cells. Reconstruction accuracy experiments are performed on the cell nucleus, and the results are compared with confocal fluorescent microscope. Intracellular nucleus delivery experiments are further conducted by using the proposed robotic microscope system. Compared with widely adopted methods without 3D information, the proposed approach demonstrates substantial improvement.
12 December 2018 in IEEE Robotics and Automation Letters
A novel micro force sensor based on depletion type vertically movable gate array field effect transistor (VMGAFET) was developed with cross-axis decoupling structure and eight gate arrays. This novel sensor is able to detect ultra-low force and exhibit high measuring sensitivity. An accurate electrical model was then proposed and compared with a long channel model, which is better adopted in small-sized devices to predict the electrical performance of this sensor. We also developed a mechanical model for the micro force sensor. Finite element method simulations were conducted, and the results were in accordance with the theoretical ones. Then, a feasible fabrication process was illustrated for the proposed sensor. The measuring sensitivity and nonlinearity of the micro force sensor with the proposed structure and dimension parameters are 12.528 μA/nN and <1.35%, respectively. These theoretical analyses provide insights into the design of depletion type VMAGFET-based sensor and other kinds of devices based on movable gate field effect transistor or with similar movable structures.
12 September 2022 in IEEE Transactions on Industrial Electronics
Precise force sensing is essential for the mechanical characterization and robotic micromanipulation of biological targets. In this work, a high-resolution microelectromechanical system capacitive force sensor is proposed for measuring ultralow multiphysics. A bionic swallow structure that contained multiple feathered comb arrays is designed for reducing chip dimension and eliminating undesirable mechanical cross-coupling effect. The comb structure is optimized for maximum sensitivity, linearity, and compact chip size. Utilizing a novel interconnection configuration, interferences derived from parasitic capacitance and electrostatic forces exerted negligible effects on the sensor output. The proposed bionic force sensor is fabricated following a simple three-mask process and integrated with application-specific integrated circuit readouts. Its measuring sensitivity is 7.151 fF/nm, 0.529 aF/nN, and 4.247 pF/g for displacement, force, and inclination measurements, respectively. The proposed sensor has a large measurement range of 1000.00 nm and 13.83 μN with a high linearity of 0.9998. The 1-σ resolution is 0.0328 nm and 0.4436 nN, and the noise floor resolution is 0.0044 nm $\sqrt {\mathbf{Hz}} $ and 0.0597 nN/ $\sqrt {\mathbf{Hz}} $ for displacement and force measurements, respectively. The bias stability of Allan deviance is 0.0050 nm and 0.0678 nN at an integration time of 0.65 s. The proposed bionic swallow sensor exhibits considerable improvement over existing capacitive sensors and feasibility for ultralow multiphysics measurement in biomedical applications.
Intracellular micromanipulation assisted by robotic systems has valuable applications in biomedical research, such as genetic diagnosis and genome-editing tasks. However, current studies suffer from a low success rate and a large operation damage because of insufficient information on the operation information of targeted specimens. The complexity of the intracellular environment causes difficulties in visualizing manipulation tools and specimens. This review summarizes and analyzes the current development of advanced biological imaging sampling and computational processing methods in intracellular micromanipulation applications. It also discusses the related limitations and future extension, providing an important reference about this field.