Global warming combined with increased production (i.e. more piglets, more milk and consequently more heat) means that sows are more often challenged by heat stress. The objective was to develop an effective temperature (ET) equation to predict how air temperature, velocity and humidity affect the respiration rate (RR), rectal temperature (RT) and skin temperature (ST) as an expression of heat stress in gestating sows in order to elucidate the relationship between the thermal parameters and the sows' perception of the environment. The experimental room was equipped with a negative pressure ventilation system with diffuse air inlet through the ceiling, electrical heaters, steam generators and dehumidifiers. An air distribution unit was constructed to generate vertical air velocity. A total of 16 gestating sows were exposed to three temperatures (25°C, 29°C and 33°C), two levels of relative humidity (30% and 70%) and three levels of air velocity (0.2 ms-1, 1 ms-1 and 2.5 ms-1). The RR, RT and ST were recorded every 30 min throughout the three 2-h test periods. The estimated effects of humidity and velocity in relation to effect of temperature was nearly independent of whether it was determined from RR or RT, whereas the effect of humidity was much smaller when determined from ST. High coefficients of determination (>0.97) were found for the second order relationship between the estimated ET and RR, RT and ST. An increase in relative humidity from 50 to 70% corresponded to an increase in ET of 0.9°C, while an increase in air velocity from 0.2 to 1.0 ms-1 corresponded to a decrease in ET of 1.2°C. The applied ET equation was useful for expressing the combined effect of temperature, humidity and velocity on animals exposed to heat stress. However, multiplying the effect of velocity by the temperature gradient between the animal and the surrounding air did not improve the estimation.
In recent years, many buildings have been fitted with smart meters, from which high-frequency energy data is available. However, extracting useful information efficiently has been imposed as a problem in utilizing these data. In this study, we analyzed district heating smart meter data from 61 buildings in Copenhagen, Denmark, focused on the peak load quantification in a building cluster and a case study on load shifting. The energy consumption data were clustered into three subsets concerning seasonal variation (winter, transition season, and summer), using the agglomerative hierarchical algorithm. The representative load profile obtained from clustering analysis were categorized by their profile features on the peak. The investigation of peak load shifting potentials was then conducted by quantifying peak load concerning their load profile types, which were indicated by the absolute peak power, the peak duration, and the sharpness of the peak. A numerical model was developed for a representative building, to determine peak shaving potentials. The model was calibrated and validated using the time-series measurements of two heating seasons. The heating load profiles of the buildings were classified into five types. The buildings with the hat shape peak type were in the majority during the winter and had the highest load shifting potential in the winter and transition season. The hat shape type’s peak load accounted for 10.7% of the total heating loads in winter, and the morning peak type accounted for 12.6% of total heating loads in the transition season. The case study simulation showed that the morning peak load was reduced by about 70%, by modulating the supply water temperature setpoints based on weather compensation curves. The methods and procedures used in this study can be applied in other cases, for the data analysis of a large number of buildings and the investigation of peak loads.