The use of electronic loads has improved many aspects of everyday life, permitting more efficient, precise and automated process. As a drawback, the nonlinear behavior of these systems entails the injection of electrical disturbances on the power grid that can cause distortion of voltage and current. In order to adopt countermeasures, it is important to detect and classify these disturbances. To do this, several Machine Learning Algorithms are currently exploited. Among them, for the present work, the Long Short Term Memory (LSTM), the Convolutional Neural Networks (CNN), the Convolutional Neural Networks Long Short Term Memory (CNN-LSTM) and the CNN-LSTM with adjusted hyperparameters are compared. As a preliminary stage of the research, the voltage and current time signals are simulated using MATLAB Simulink. Thanks to the simulation results, it is possible to acquire a current and voltage dataset with which the identification algorithms are trained, validated and tested. These datasets include simulations of several disturbances such as Sag, Swell, Harmonics, Transient, Notch and Interruption. Data Augmentation techniques are used in order to increase the variability of the training and validation dataset in order to obtain a generalized result. After that, the networks are fed with an experimental dataset of voltage and current field measurements containing the disturbances mentioned above. The networks have been compared, resulting in a 79.14% correct classification rate with the LSTM network versus a 84.58% for the CNN, 84.76% for the CNN-LSTM and a 83.66% for the CNN-LSTM with adjusted hyperparameters. All of these networks are tested using real measurements.

26 August 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
CICarlos Iturrino
Carlos Iturrino
Gabriele PatriziGabriele Patrizi
Gabriele Patrizi
ABAlessandro Bartolini
Alessandro Bartolini
LCLorenzo Ciani
Lorenzo Ciani
Libero PaolucciLibero Paolucci
Libero Paolucci
Francesco GrassoFrancesco Grasso
Francesco Grasso
Power Quality Disturbances (PQD) have affected many people due to the growing number of electronic nonlinear loads and because of the significant increase of renewable sources connected to the grid. Previous works have shown the development of algorithms to detect and classify these disturbances. A thorough review of PQD detector algorithms pointed out the use of machine learning and deep learning algorithms as the most used, accurate and up-to-date approaches to deal with this problem. Up until now, these algorithms were used in a sliding window manner that often fail to identify more than one disturbance in a single window frame. In this work, an innovative architecture called Single Shot Power Quality Disturbance Detection (SSPQDD) has been developed to solve this problem. Several experiments were conducted using a simulation dataset in order to validate the performances of the proposed SSPQDD in comparison with other algorithms available in literature in terms of computational resources, accuracy of identification and number of layers. Furthermore, an experimental testbench has been carried out to test the performances of SSPQDD using real measurement data in case of multiple disturbances in a single window frame. The overall accuracy obtained using the proposed SSPQDD was 96.55% in PQD detection.

10 December 2020 in Energies
Verified
Journal Article
Open access
PDF file
Fabio CortiFabio Corti
Fabio Corti
Alberto ReattiAlberto Reatti
Alberto Reatti
ANAndrea Nepote
Andrea Nepote
Luca PugiLuca Pugi
Luca Pugi
MPMarco Pierini
Marco Pierini
MNMatthias Nienhaus
Matthias Nienhaus
In this paper, the design procedure of an electric vehicle (EV) wireless charger is presented. Unlike most of the systems available in the literature, the proposed charging system is regulated from the vehicle side. The on-board electrical circuit automatically adapts the resonant compensation to guarantee compatibility with the primary inverter characteristics and achieve high transmission efficiency without communication between sides. Moreover, the proposed control strategy, used to regulate the secondary full active rectifier (FAR), allows the supply of the the EV battery, maximizing the efficiency during the whole charging process.

23 April 2023 in Energies
Verified
Journal Article
Open access
PDF file
CICarlos Iturrino
Carlos Iturrino
Marco BindiMarco Bindi
Marco Bindi
Fabio CortiFabio Corti
Fabio Corti
Antonio LuchettaAntonio Luchetta
Antonio Luchetta
Francesco GrassoFrancesco Grasso
Francesco Grasso
IAIgor Aizenberg
Igor Aizenberg
The main objective of this paper is to propose two innovative monitoring methods for electrical disturbances in low-voltage networks. The two approaches present a focus on the classification of voltage signals in the frequency domain using machine learning techniques. The first technique proposed here uses the Fourier transform (FT) of the voltage waveform and classifies the corresponding complex coefficients through a multilayered neural network with multivalued neurons (MLMVN). In this case, the classifier structure has three layers and a small number of neurons in the hidden layer. This allows complex-valued inputs to be processed without the need for pre-coding, thus reducing computational cost and keeping training time short. The second technique involves the use of the short-time Fourier transform (STFT) and a convolutional neural network (CNN) with 2D convolutions in each layer for feature extraction and dimensionality reduction. The voltage waveform perturbations taken into consideration are: voltage sag, voltage swell, harmonic pollution, voltage notch, and interruption. The comparison between the two proposed techniques is developed in two phases: initially, the simulated data used during the training phase are considered and, subsequently, various experimental measurements are processed, obtained both through an artificial disturbance generator and through a variable load. The two techniques represent an innovative approach to this problem and guarantee excellent classification results.

6 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Gabriele PatriziGabriele Patrizi
Gabriele Patrizi
CGCristian Camilo Garzon-Alfonso
Cristian Camilo Garzon-Alfonso
LCLeandro Calandroni
Leandro Calandroni
ABAlessandro Bartolini
Alessandro Bartolini
CICarlos Iturrino
Carlos Iturrino
LCLorenzo Ciani
Lorenzo Ciani
The problem of Power Quality analysis is becoming crucial to ensuring the proper functioning of complex systems and big plants. In this regard, it is essential to rapidly detect anomalies in voltage and current signals to ensure a prompt response and maximize the system’s availability with the minimum maintenance cost. In this paper, anomaly detection algorithms based on machine learning, such as One Class Support Vector Machine (OCSVM), Isolation Forest (IF), and Angle-Based Outlier Detection (ABOD), are used as a first tool for rapid and effective clustering of the measured voltage and current signals directly on-line on the sensing unit. If the proposed anomaly detection algorithm detects an anomaly, further investigations using suitable classification algorithms are required. The main advantage of the proposed solution is the ability to rapidly and efficiently detect different types of anomalies with low computational complexity, allowing the implementation of the algorithm directly on the sensor node used for signal acquisition. A suitable experimental platform has been established to evaluate the advantages of the proposed method. All the different models were tested using a consistent set of hyperparameters and an output dataset generated from the principal component analysis technique. The best results achieved included models reaching 100% recall and a 92% F1 score.

1 December 2021