Marco Bindi

Mr. Marco Bindi

University of Florence - Department of Information Engineering (DINFO)
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 October 2023 in Energies
Verified
Journal Article
Open access
PDF file
Marco BindiMarco Bindi
Marco Bindi
MPMaria Cristina Piccirilli
Maria Cristina Piccirilli
Antonio LuchettaAntonio Luchetta
Antonio Luchetta
Francesco GrassoFrancesco Grasso
Francesco Grasso
This paper presents an extensive review of the most effective and modern monitoring methods for electrical power lines, with particular attention to high-voltage (HV) and medium-voltage (MV) systems. From a general point of view, the main objective of these techniques is to prevent catastrophic failures by detecting the partial damage or deterioration of components and allowing maintenance operations to be organized. In fact, the protection devices commonly used in transmission and distribution networks guarantee the location of faults, such as short-circuits, putting the non-functioning branch of the network out of service. Nowadays, alongside these devices, it is possible to introduce new intelligent algorithms capable of avoiding the total loss of functionality, thus improving the reliability of the entire network. This is one of the main challenges in modern smart grids, which are characterized by the massive integration of renewable energy sources and a high level of complexity. Therefore, in the first part of this paper, a general overview of the most common protection devices is proposed, followed by an analysis of the most modern prevention algorithms. In the first case, the coordination of the relays plays a fundamental role in obtaining the fault location with a high level of selectivity, while in the field of preventive analysis, it is necessary to address the implementation of artificial intelligence methods. The techniques presented in this paper provide a comprehensive description of the different monitoring approaches currently used in distribution and transmission lines, highlighting the coordination of protection relays, the computational algorithms capable of preventing failures, and the influence of the distributed generation in their management. Therefore, this paper offers an overview of the main diagnostic techniques and protection devices, highlights the critical issues that can be overcome through the introduction of artificial intelligence, and describes the main prognostic methods, focusing on their invasive level and the possibility of operating directly online. This work also highlights the main guidelines for the classification and choice between the different approaches.

23 February 2022 in Algorithms
Verified
Journal Article
Open access
PDF file
Marco BindiMarco Bindi
Marco Bindi
Fabio CortiFabio Corti
Fabio Corti
Igor AizenbergIgor Aizenberg
Igor Aizenberg
Francesco GrassoFrancesco Grasso
Francesco Grasso
Gabriele Maria LozitoGabriele Maria Lozito
Gabriele Maria Lozito
Alberto ReattiAlberto Reatti
Alberto Reatti
In this paper, a monitoring method for DC-DC converters in photovoltaic applications is presented. The primary goal is to prevent catastrophic failures by detecting malfunctioning conditions during the operation of the electrical system. The proposed prognostic procedure is based on machine learning techniques and focuses on the variations of passive components with respect to their nominal range. A theoretical study is proposed to choose the best measurements for the prognostic analysis and adapt the monitoring method to a photovoltaic system. In order to facilitate this study, a graphical assessment of testability is presented, and the effects of the variable solar irradiance on the selected measurements are also considered from a graphical point of view. The main technique presented in this paper to identify the malfunction conditions is based on a Multilayer neural network with Multi-Valued Neurons. The performances of this classifier applied on a Zeta converter are compared to those of a Support Vector Machine algorithm. The simulations carried out in the Simulink environment show a classification rate higher than 90%, and this means that the monitoring method allows the identification of problems in the initial phases, thus guaranteeing the possibility to change the work set-up and organize maintenance operations for DC-DC converters.

1 March 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Marco BindiMarco Bindi
Marco Bindi
Fabio CortiFabio Corti
Fabio Corti
Francesco GrassoFrancesco Grasso
Francesco Grasso
Antonio LuchettaAntonio Luchetta
Antonio Luchetta
Stefano ManettiStefano Manetti
Stefano Manetti
Alberto ReattiAlberto Reatti
Alberto Reatti
In this article, we propose a monitoring procedure based on a multilayer neural network with multivalued neurons (MLMVN) capable of preventing catastrophic failures of dc–dc converters. The neural classifier allows both the detection of any malfunction and its localization. Thanks to the low computational complexity, the proposed method operates online, estimating the deviations of the passive components from their nominal values: this allows control strategies to be promptly adopted and operation of the dc–dc converter to be kept in high efficiency and reliability conditions. Since measuring the voltage and current on each component increases the complexity of the system, a testability analysis is proposed with the aim of identifying the minimum number of measurements needed to distinguish the classes of failure. To make the testability phase easier and more intuitive, a graphical representation is proposed. As a case study, prognostic analysis has been applied to prevent catastrophic failures in a synchronous Zeta converter. Several fault conditions have been analyzed through simulations and experimental tests. The obtained results confirm the ability of the proposed method to prevent failures and, also, show that the application of MLMVN results in a better performance than classic solutions available in the literature, such as support vector machine.

23 April 2023 in Energies
Verified
Journal Article
Open access
PDF file
CICarlos Iturrino
Carlos Iturrino
Marco BindiMarco Bindi
Marco Bindi
Fabio CortiFabio Corti
Fabio Corti
Antonio LuchettaAntonio Luchetta
Antonio Luchetta
Francesco GrassoFrancesco Grasso
Francesco Grasso
IAIgor Aizenberg
Igor Aizenberg
The main objective of this paper is to propose two innovative monitoring methods for electrical disturbances in low-voltage networks. The two approaches present a focus on the classification of voltage signals in the frequency domain using machine learning techniques. The first technique proposed here uses the Fourier transform (FT) of the voltage waveform and classifies the corresponding complex coefficients through a multilayered neural network with multivalued neurons (MLMVN). In this case, the classifier structure has three layers and a small number of neurons in the hidden layer. This allows complex-valued inputs to be processed without the need for pre-coding, thus reducing computational cost and keeping training time short. The second technique involves the use of the short-time Fourier transform (STFT) and a convolutional neural network (CNN) with 2D convolutions in each layer for feature extraction and dimensionality reduction. The voltage waveform perturbations taken into consideration are: voltage sag, voltage swell, harmonic pollution, voltage notch, and interruption. The comparison between the two proposed techniques is developed in two phases: initially, the simulated data used during the training phase are considered and, subsequently, various experimental measurements are processed, obtained both through an artificial disturbance generator and through a variable load. The two techniques represent an innovative approach to this problem and guarantee excellent classification results.

2 February 2021 in Electronics
Verified
Journal Article
Open access
PDF file
Igor AizenbergIgor Aizenberg
Igor Aizenberg
Riccardo BelardiRiccardo Belardi
Riccardo Belardi
Marco BindiMarco Bindi
Marco Bindi
Francesco GrassoFrancesco Grasso
Francesco Grasso
Stefano ManettiStefano Manetti
Stefano Manetti
MPMaria Cristina Piccirilli
Maria Cristina Piccirilli
In this paper, we present a new method designed to recognize single parametric faults in analog circuits. The technique follows a rigorous approach constituted by three sequential steps: calculating the testability and extracting the ambiguity groups of the circuit under test (CUT); localizing the failure and putting it in the correct fault class (FC) via multi-frequency measurements or simulations; and (optional) estimating the value of the faulty component. The fabrication tolerances of the healthy components are taken into account in every step of the procedure. The work combines machine learning techniques, used for classification and approximation, with testability analysis procedures for analog circuits.

25 April 2023 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Marco BindiMarco Bindi
Marco Bindi
Antonio LuchettaAntonio Luchetta
Antonio Luchetta
Gabriele Maria LozitoGabriele Maria Lozito
Gabriele Maria Lozito
Carlo CarobbiCarlo Carobbi
Carlo Carobbi
Francesco GrassoFrancesco Grasso
Francesco Grasso
MPMaria Cristina Piccirilli
Maria Cristina Piccirilli
This paper proposes a new prognostic method capable of preventing catastrophic failures in Medium Voltage (MV) power cables. The main objective is the development of a monitoring system focused on the detection and localization of cable overtemperatures in underground distribution networks. The predictive analysis proposed here is based on a Multi-Layer neural network with Multi-Valued Neurons (MLMVN), which elaborates measurements of high frequency signals transmitted through Power Line Communication (PLC) devices. Therefore, the prognostic method does not require the introduction of additional components since the power line is already equipped with a communication system. This allows low intrusion and the possibility of monitoring power lines during their operation. Furthermore, the MLMVN-based classifier processes magnitude and phase of the received signals without preliminary coding steps and ensures a low computational cost. The main theoretical concept on which the predictive analysis is based is the detection of malfunctions starting from their effects on the cable parameters. For this reason, an RG7H1M1 cable has been experimentally characterized in the frequency range between 90 kHz and 1 MHz, both in nominal conditions and in overheating situations generated by means of a climatic chamber. The changes in the electrical parameters of the cable modify the transmitted signal and the monitoring system proposed here allows the identification and localization of the overheated section with high accuracy.