Nassif Nabil

Dr. Nassif Nabil

Department of Civil and Architectural Engineering, University of Cincinnati, Oh, USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 November 2020 in Buildings
Verified
Journal Article
Open access
PDF file
IRIffat Ridwana
Iffat Ridwana
Nassif NabilNassif Nabil
Nassif Nabil
WCWonchang Choi
Wonchang Choi
With the constant expansion of the building sector as a major energy consumer in the modern world, the significance of energy-efficient building systems cannot be more emphasized. Most of the buildings are now equipped with an electric dashboard to record consumption data which presents a significant scope of research by utilizing those data in energy modeling. This paper investigates conventional regression modeling in building energy estimation and proposes three models with data classifications to improve their performance. The proposed models are regression models and an artificial neural network model with data classification for predicting hourly or sub-hourly energy usage in four different buildings. Energy data is collected from a building energy simulation program and existing buildings to develop the models for detailed analysis. Data classification is recommended according to the system operating schedules of the buildings and models are tested for their performance in capturing the data trends resulting from those schedules. Proposed regression models and an ANN model with the recommended classification show very accurate results in estimating energy demand compared to conventional regression models. Correlation coefficient and root mean squared error values improve noticeably for the proposed models and they can potentially be utilized for energy conservation purposes and energy savings in the buildings.

14 March 2022 in Buildings
Verified
Journal Article
Open access
PDF file
Nassif NabilNassif Nabil
Nassif Nabil
MTmostafa tahmasebi
mostafa tahmasebi
IRIffat Ridwana
Iffat Ridwana
PEPejman Ebrahimi
Pejman Ebrahimi
Buildings account for a large portion of the total energy use in the US; therefore, improving the operation of typical variable-air-volume (VAV) systems in buildings can provide a tremendous economic opportunity. ASHRAE Guideline 36 recommends a resetting strategy for supply air temperature (SAT) for VAV systems based on outside air temperature. However, this strategy may not produce optimal performance, particularly when simultaneous cooling and heating occurs in zones. In addition, there is no strategy recommended in the Guideline to reset the zone minimum airflow set point in a single-duct VAV terminal unit with reheat, although this setpoint has a great impact on zone reheat requirements and ventilation efficiency. Thus, this paper introduces new strategies to reset both the SAT and zone minimum airflow rate set points to improve the efficiency of typical VAV systems. The strategies were tested under various conditions through experiments performed in fully instrumented VAV systems located in the HVAC lab at the University of Cincinnati. The experiments were conducted on a chilled-water VAV system that serves three controlled zones with hot-water reheat VAV boxes controlled by a typical commercial BACnet web-based building automation system BAS. The simulation studies were performed using the building energy simulation software EnergyPlus to evaluate the strategies at a larger scale in various locations. The simulation results show that the proposed resetting strategies can provide fan energy savings between 1.6% and 5.7% and heating load savings between 7.7% to 33.7%, depending on the location. The laboratory testing shows that the proposed strategies can provide stable control performance in actual systems as well as achieving the anticipated reheat and fan energy savings. The result offers significant improvements that can be implemented in the Guideline for single-duct VAV system operation and control.

13 September 2020 in Buildings
Verified
Journal Article
Open access
PDF file
RTRand Talib
Rand Talib
Nassif NabilNassif Nabil
Nassif Nabil
WCWonchang Choi
Wonchang Choi
Most of the energy consumed by the residential and commercial buildings in the U.S. is dedicated to space cooling and heating systems, according to the U.S. Energy Information Administration. Therefore, the need for better operation mechanisms of those existing systems become more crucial. The most vital factor for that is the need for accurate models that can accurately predict the system component performance. Therefore, this paper’s primary goal is to develop a new accurate data-driven modeling and optimization technique that can accurately predict the performance of the selected system components. Several data-enabled modeling techniques such as artificial neural networks (ANN), support vector machine (SVM), and aggregated bootstrapping (BSA) are investigated, and model improvements through model structure optimization proposed. The optimization algorithm will determine the optimal model structures and automate the process of the parametric study. The optimization problem is solved using a genetic algorithm (GA) to reduce the error between the simulated and actual data for the testing period. The models predicted the performance of the chilled water variable air volume (VAV) system’s main components of cooling coil and fan power as a function of multiple inputs. Additionally, the packaged DX system compressor modeled, and the compressor power was predicted. The testing results held a low coefficient of variation (CV%) values of 1.22% for the cooling coil, and for the fan model, it was found to be 9.04%. The testing results showed that the proposed modeling and optimization technique could accurately predict the system components’ performance.

4 May 2023 in Buildings
Verified
Journal Article
Open access
PDF file
PEPejman Ebrahimi
Pejman Ebrahimi
IRIffat Ridwana
Iffat Ridwana
Nassif NabilNassif Nabil
Nassif Nabil
The building sector accounts for a substantial amount of energy consumption, resulting in higher carbon emissions and environmental impact worldwide. Electrification and energy efficiency in building systems can be the key to decarbonization in buildings. This research proposes new heating and cooling loops consisting of heat pumps to lower natural gas usage in building systems. Typical chillers and boilers in the cooling and heating loops are replaced with heat pumps to serve the loads and maintain thermal comfort in the building. In addition, a new optimal supply air temperature (SAT) reset strategy is also implemented with the proposed configuration for better system performance. A large multi-zone office building is simulated as a case study to measure the conventional system’s electricity and natural gas consumption and the proposed design. Even with heat pumps that use electricity as the energy source, electricity consumption is reduced by 3.3% to 11.8% in different climate zones for the proposed system. On the other hand, 10.2% to 67% lower natural gas is consumed when the proposed system and the optimal SAT reset are utilized. The carbon emission is also reduced by 10.8% to 38% compared to the conventional system. The results show that the proposed design and optimization strategy can lead to significant energy and cost savings in conjunction with lower carbon emissions.

18 October 2021 in Buildings
Verified
Journal Article
Open access
PDF file
RTRand Talib
Rand Talib
Nassif NabilNassif Nabil
Nassif Nabil
According to EIA, the Heating Ventilation and Air Conditioning (HAVC) systems account for about 25% of the U.S.’s total commercial building’s energy use. Therefore, advanced modeling and optimization methods of the system components and operation offer great ways to reduce energy consumption in all types of buildings and mainly commercial buildings. This research introduced an innovative integrated two-level optimization technique for the HVAC system to reduce the total energy consumption while improving the indoor thermal comfort level. The process uses actual system performance data collected for the building automation systems (BAS) to create accurate component modeling and optimization process as the first level of optimization (MLO). Artificial neural networks were chosen to be the tool used to serve the process of modeling. The second optimization level utilizes the whole system-level optimization technique (SLO) using a genetic algorithm (G.A.). The proposed two-levels optimization technique will optimize the system setpoints, the supply air temperature, duct static pressure, minimum zone air flowrates, and minimum outdoor air ventilation rate. The proposed technique has contributed to the field of modeling and optimization of HVAC systems through several new contributions. (1) Implementing the demand control methodology with the optimization process to modify the electricity consumption power profile when the demand signal is received. (2) Implement the occupancy schedule inputs into the optimization process to adjust the ventilation airflow rates accordingly. (3) Implement the real-time zone occupancy sensor readings and adjust the zone’s ventilation flowrates and minimum flowrates. (4) Lastly, implementing the method of zone minimum air flowrates setpoint rests to reduce reheat requirements. The proposed optimization process was tested and validated, resulting in savings in the total energy consumed by the chilled water VAV system by 13.4%, 22.4 %, followed by 31% for July, February, and October, respectively.

5 August 2025 in Buildings
Verified
Journal Article
Open access
PDF file
YJYosef Naim Jaber
Yosef Naim Jaber
PDPasidu Madewa Dharmasena
Pasidu Madewa Dharmasena
ANAdam Nassif
Adam Nassif
Nassif NabilNassif Nabil
Nassif Nabil
Heating, Ventilation, and Air Conditioning (HVAC) systems represent a significant portion of global energy use, yet they are often operated without optimized control strategies. This study explores the application of deep learning to accurately model heating system behavior as a foundation for predictive control and energy-efficient HVAC operation. Experimental data were collected under controlled laboratory conditions, and 288 unique hyperparameter configurations were developed. Each configuration was tested three times, resulting in a total of 864 artificial neural network models. Five key hyperparameters were varied systematically: number of epochs, network size, network shape, learning rate, and optimizer. The best-performing model achieved a mean squared error of 0.469 and featured 17 hidden layers, a left-triangle architecture trained for 500 epochs with a learning rate of 5 × 10−5, and Adam as the optimizer. The results highlighted the importance of hyperparameter tuning in improving model accuracy. Future research should extend the analysis to incorporate cooling operation and real-world building operation data for broader applicability.