Pejman Ebrahimi

Mr. Pejman Ebrahimi


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 March 2022 in Buildings
Verified
Journal Article
Open access
PDF file
Nassif NabilNassif Nabil
Nassif Nabil
MTmostafa tahmasebi
mostafa tahmasebi
IRIffat Ridwana
Iffat Ridwana
PEPejman Ebrahimi
Pejman Ebrahimi
Buildings account for a large portion of the total energy use in the US; therefore, improving the operation of typical variable-air-volume (VAV) systems in buildings can provide a tremendous economic opportunity. ASHRAE Guideline 36 recommends a resetting strategy for supply air temperature (SAT) for VAV systems based on outside air temperature. However, this strategy may not produce optimal performance, particularly when simultaneous cooling and heating occurs in zones. In addition, there is no strategy recommended in the Guideline to reset the zone minimum airflow set point in a single-duct VAV terminal unit with reheat, although this setpoint has a great impact on zone reheat requirements and ventilation efficiency. Thus, this paper introduces new strategies to reset both the SAT and zone minimum airflow rate set points to improve the efficiency of typical VAV systems. The strategies were tested under various conditions through experiments performed in fully instrumented VAV systems located in the HVAC lab at the University of Cincinnati. The experiments were conducted on a chilled-water VAV system that serves three controlled zones with hot-water reheat VAV boxes controlled by a typical commercial BACnet web-based building automation system BAS. The simulation studies were performed using the building energy simulation software EnergyPlus to evaluate the strategies at a larger scale in various locations. The simulation results show that the proposed resetting strategies can provide fan energy savings between 1.6% and 5.7% and heating load savings between 7.7% to 33.7%, depending on the location. The laboratory testing shows that the proposed strategies can provide stable control performance in actual systems as well as achieving the anticipated reheat and fan energy savings. The result offers significant improvements that can be implemented in the Guideline for single-duct VAV system operation and control.

4 May 2023 in Buildings
Verified
Journal Article
Open access
PDF file
PEPejman Ebrahimi
Pejman Ebrahimi
IRIffat Ridwana
Iffat Ridwana
Nassif NabilNassif Nabil
Nassif Nabil
The building sector accounts for a substantial amount of energy consumption, resulting in higher carbon emissions and environmental impact worldwide. Electrification and energy efficiency in building systems can be the key to decarbonization in buildings. This research proposes new heating and cooling loops consisting of heat pumps to lower natural gas usage in building systems. Typical chillers and boilers in the cooling and heating loops are replaced with heat pumps to serve the loads and maintain thermal comfort in the building. In addition, a new optimal supply air temperature (SAT) reset strategy is also implemented with the proposed configuration for better system performance. A large multi-zone office building is simulated as a case study to measure the conventional system’s electricity and natural gas consumption and the proposed design. Even with heat pumps that use electricity as the energy source, electricity consumption is reduced by 3.3% to 11.8% in different climate zones for the proposed system. On the other hand, 10.2% to 67% lower natural gas is consumed when the proposed system and the optimal SAT reset are utilized. The carbon emission is also reduced by 10.8% to 38% compared to the conventional system. The results show that the proposed design and optimization strategy can lead to significant energy and cost savings in conjunction with lower carbon emissions.