Buildings account for a large portion of the total energy use in the US; therefore, improving the operation of typical variable-air-volume (VAV) systems in buildings can provide a tremendous economic opportunity. ASHRAE Guideline 36 recommends a resetting strategy for supply air temperature (SAT) for VAV systems based on outside air temperature. However, this strategy may not produce optimal performance, particularly when simultaneous cooling and heating occurs in zones. In addition, there is no strategy recommended in the Guideline to reset the zone minimum airflow set point in a single-duct VAV terminal unit with reheat, although this setpoint has a great impact on zone reheat requirements and ventilation efficiency. Thus, this paper introduces new strategies to reset both the SAT and zone minimum airflow rate set points to improve the efficiency of typical VAV systems. The strategies were tested under various conditions through experiments performed in fully instrumented VAV systems located in the HVAC lab at the University of Cincinnati. The experiments were conducted on a chilled-water VAV system that serves three controlled zones with hot-water reheat VAV boxes controlled by a typical commercial BACnet web-based building automation system BAS. The simulation studies were performed using the building energy simulation software EnergyPlus to evaluate the strategies at a larger scale in various locations. The simulation results show that the proposed resetting strategies can provide fan energy savings between 1.6% and 5.7% and heating load savings between 7.7% to 33.7%, depending on the location. The laboratory testing shows that the proposed strategies can provide stable control performance in actual systems as well as achieving the anticipated reheat and fan energy savings. The result offers significant improvements that can be implemented in the Guideline for single-duct VAV system operation and control.
1 March 2022 in American Journal of Engineering and Applied Sciences
The building sector accounts for more than 70% of thetotal electricity use. Chillers consume more than 50% of electrical energyduring seasonal periods of building use. With the growth of the building sectorand climate change, it's essential to develop energy-efficient HVAC systemsthat optimize the ever-increasing energy demand. This study aims to develop anenergy consumption prediction model for air-cooled chillers using machinelearning algorithms. This is done by developing different static and dynamicdata-driven regressive and neural network models and comparing the accuracy oftheir prediction to identify the most accurate modeling algorithm using 3 maininputs chilled water return temperature, outside drybulb temperature, andcooling load. The proposed model structure was then optimized in terms of thenumber of neurons, epochs, time delays aswell as the number of input variables using a genetic algorithm. Training andtesting were done using real data obtained from a fully instrumented 4-tonair-cooled chiller. Results of the study show that the optimized artificialneural network model can predict energy consumption with a high level ofaccuracy compared to conventional modeling techniques. The development ofhighly accurate self-tuning models can be a powerful tool to use for otherapplications such as fault detection and diagnosis, assessment, and systemoptimization. Further studies are necessary to evaluate the effectiveness ofusing deep learning algorithms with more hidden layers and cross-validationtechniques.