Philip Basford

Dr. Philip Basford

School of Engineering, University of Southampton, SO17 1BJ, UK
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2020 in Sensors
Verified
Journal Article
Open access
PDF file
PBPhilip Basford
Philip Basford
FBFlorentin Bulot
Florentin Bulot
MAMihaela Apetroaie-Cristea
Mihaela Apetroaie-Cristea
SCSimon J. Cox
Simon J. Cox
Steven OssontSteven Ossont
Steven Ossont
LoRaWAN is a Low-Power Wide Area Network (LPWAN) technology designed for Internet of Things (IoT) deployments; this paper presents experiences from deploying a city-scale LoRaWAN network across Southampton, UK. This network was deployed to support an installation of air quality monitors and to explore the capabilities of LoRaWAN. This deployment uses a mixture of commercial off-the-shelf gateways and custom gateways. These gateway locations were chosen based on network access, site permission and accessibility, and are not necessarily the best locations theoretically. Over 135,000 messages have been transmitted by the twenty devices analysed. Over the course of the complete deployment, 72.4 % of the messages were successfully received by the data server. Of the messages that were received, 99% were received within 10 s of transmission. We conclude that LoRaWAN is an applicable communication technology for city-scale air quality monitoring and other smart city applications.

8 January 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Steven OssontSteven Ossont
Steven Ossont
PBPhilip Basford
Philip Basford
FBFlorentin Bulot
Florentin Bulot
MAMihaela Apetroaie-Cristea
Mihaela Apetroaie-Cristea
NENatasha H. C. Easton
Natasha H. C. Easton
SCSimon J Cox
Simon J Cox
Air Quality (AQ) is a very topical issue for many cities and has a direct impact on citizen health. The AQ of a large UK city is being investigated using low-cost Particulate Matter (PM) sensors, and the results obtained by these sensors have been compared with government operated AQ stations. In the first pilot deployment, six AQ Internet of Things (IoT) devices have been designed and built, each with four different low-cost PM sensors, and they have been deployed at two locations within the city. These devices are equipped with LoRaWAN wireless network transceivers to test city scale Low-Power Wide Area Network (LPWAN) coverage. The study concludes that (i) the physical device developed can operate at a city scale; (ii) some low-cost PM sensors are viable for monitoring AQ and for detecting PM trends; (iii) LoRaWAN is suitable for city scale sensor coverage where connectivity is an issue. Based on the findings from this first pilot project, a larger LoRaWAN enabled AQ sensor network is being deployed across the city of Southampton in the UK.

1 December 2018 in Future Generation Computer Systems
Verified
Journal Article
Open access
SJSteven J. Johnston
Steven J. Johnston
PBPhilip Basford
Philip Basford
CPColin S. Perkins
Colin S. Perkins
HHHerry Herry
Herry Herry
FTFung Po Tso
Fung Po Tso
JSJeremy Singer
Jeremy Singer

15 April 2020 in Sensors
Verified
Journal Article
Open access
PDF file
FBFlorentin Bulot
Florentin Bulot
Hugo Savill RussellHugo Savill Russell
Hugo Savill Russell
MRMohsen Rezaei
Mohsen Rezaei
Matthew Stanley JohnsonMatthew Stanley Johnson
Matthew Stanley Johnson
Steven OssontSteven Ossont
Steven Ossont
SCSimon J Cox
Simon J Cox
Airborne particulate matter (PM) exposure has been identified as a key environmental risk factor, associated especially with diseases of the respiratory and cardiovascular system and with almost 9 million premature deaths per year. Low-cost optical sensors for PM measurement are desirable for monitoring exposure closer to the personal level and particularly suited for developing spatiotemporally dense city sensor networks. However, questions remain over the accuracy and reliability of the data they produce, particularly regarding the influence of environmental parameters such as humidity and temperature, and with varying PM sources and concentration profiles. In this study, eight units each of five different models of commercially available low-cost optical PM sensors (40 individual sensors in total) were tested under controlled laboratory conditions, against higher-grade instruments for: lower limit of detection, response time, responses to sharp pollution spikes lasting <1 min , and the impact of differing humidity and PM source. All sensors detected the spikes generated with a varied range of performances depending on the model and presenting different sensitivity mainly to sources of pollution and to size distributions with a lesser impact of humidity. The sensitivity to particle size distribution indicates that the sensors may provide additional information to PM mass concentrations. It is concluded that improved performance in field monitoring campaigns, including tracking sources of pollution, could be achieved by using a combination of some of the different models to take advantage of the additional information made available by their differential response.

1 January 2020 in Future Generation Computer Systems
Verified
Journal Article
Open access
PBPhilip Basford
Philip Basford
SJSteven J. Johnston
Steven J. Johnston
CPColin S. Perkins
Colin S. Perkins
TGTony Garnock-Jones
Tony Garnock-Jones
FTFung Po Tso
Fung Po Tso
SCSimon J. Cox
Simon J. Cox

29 April 2023 in Heliyon
Verified
Journal Article
Open access
FBFlorentin Bulot
Florentin Bulot
Steven OssontSteven Ossont
Steven Ossont
AMAndrew Morris
Andrew Morris
PBPhilip Basford
Philip Basford
NENatasha H.C. Easton
Natasha H.C. Easton
MLMatthew Loxham
Matthew Loxham
Particulate Matter (PM) low-cost sensors (LCS) present a cost-effective opportunity to improve the spatiotemporal resolution of airborne PM data. Previous studies focused on PM-LCS-reported hourly data and identified, without fully addressing, their limitations. However, PM-LCS provide measurements at finer temporal resolutions. Furthermore, government bodies have developed certifications to accompany new uses of these sensors, but these certifications have shortcomings. To address these knowledge gaps, PM-LCS of two models, 8 Sensirion SPS30 and 8 Plantower PMS5003, were collocated for one year with a Fidas 200S, MCERTS-certified PM monitor and were characterised at 2 min resolution, enabling replication of certification processes, and highlighting their limitations and improvements. Robust linear models using sensor-reported particle number concentrations and relative humidity, coupled with 2-week biannual calibration campaigns, achieved reference-grade performance, at median PM2.5 background concentration of 5.5 μg/m3, demonstrating that, with careful calibration, PM-LCS may cost-effectively supplement reference equipment in multi-nodes networks with fine spatiotemporality.