Chenge Wang

Dr. Chenge Wang


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 November 2020 in Electronics
Verified
Journal Article
Open access
PDF file
XPXiaoye Peng
Xiaoye Peng
ZWZhiyu Wang
Zhiyu Wang
JMJiongjiong Mo
Jiongjiong Mo
CWChenge Wang
Chenge Wang
JLJiarui Liu
Jiarui Liu
FYFaxin Yu
Faxin Yu
Frequency-dependent I/Q imbalance and frequency-independent I/Q imbalance are the major impairments in wideband zero-IF receivers, and they both cannot be ignored. In this paper, a blind calibration model is designed for compensating these I/Q imbalances. In order to accurately estimate the imbalance parameters with low cost, a classification rule is proposed according to the frequency-domain statistical characteristics of the received signal. The calibration points in the frequency-domain are divided into two groups. Then, the amplitude imbalance and the frequency-dependent phase imbalance are derived from the group of signal points and, separately, the frequency-independent phase imbalance is calculated from the group of noise points. In the derivation of the frequency-dependent phase imbalance, a general fitting model suitable for all signal points is proposed, which does not require special calculations for either DC point or fs/2 point. Then, a finite impulse response (FIR) real-valued filter is designed to correct the impairments of received signal. The performances of the proposed calibration model are evaluated through both simulations and experiments. The simulation results show the image rejection ratio (IRR) improvement to around 35–45 dBc at high signal-to-noise ratio (SNR). Based on the mismatched data of the ADRV9009 evaluation board, the experimental results exhibit the IRR improvement of both multi-tone and wideband signals to about 30 dBc.

25 April 2024 in Electronics
Verified
Journal Article
Open access
PDF file
RWRuhao Wang
Ruhao Wang
PGPeng Gao
Peng Gao
JLJiarui Liu
Jiarui Liu
ZWZhiyu Wang
Zhiyu Wang
CWChenge Wang
Chenge Wang
FYFaxin Yu
Faxin Yu
A generic transmitter (TX) I/Q imbalance self-calibration method, which was designed based on a hybrid analog and digital structure, is proposed in this paper. The whole calibration scheme was implemented using low-complexity digital–analog circuits based on a zero-force feedback loop. In order to eliminate the negative effect of local oscillator (LO) harmonics on the calibration, we used a variable-delay line (VDL) in the analog domain instead of the digital phase compensator. The prototype chip was fabricated within a 0.2∼5.0 GHz direct-conversion transmitter in a 65 nm CMOS process, and measurements found an image rejection ratio (IRR) of 65 dBc.

10 August 2022 in IEICE Electronics Express
Verified
Journal Article
Closed access
PDF file
YLYu Liu
Yu Liu
MCMingliang Chen
Mingliang Chen
CWChenge Wang
Chenge Wang
JLJiarui Liu
Jiarui Liu
ZWZhiyu Wang
Zhiyu Wang
FYFaxin Yu
Faxin Yu
This letter proposes a parasitic elimination bootstrapped switch and a fast settling residual amplifier to be used in multiplying digital-to-analog converter (MDAC) in order to improve the performance of pipelined ADC at high frequency. The parasitic elimination bootstrapped switch improves the sampling spurious free dynamic range (SFDR) by more than 6dB by shielding the nonlinear parasitic capacitance of the MOS transistor substrate. In addition, at high frequency, the negative zero point introduced by the later stage switch-capacitor circuit (which is easy to be ignored) will seriously deteriorates the settling time of residual amplifier in the former stage. A new zero-pole elimination technique is proposed, which greatly reduces the settling time of residual amplifier by nearly 11% and further improve the performance of MDAC. Simulated in 28nm CMOS technology, as the input signal is 1.38GHz, the former stage of the pipelined ADC implements high-speed high-resolution to obtain a SFDR of 75.77dB and a signal-to-noise-plus-distortion ratio (SNDR) of 68.05dB at a sampling frequency of 2.2GS/s.