Francesco Barbon

Francesco Barbon

Auto-generated profile, based on publicly available information

Francesco Barbon

Institute for Electronics Engineering, University of Erlangen-Nuremberg, Cauerstr. 9, 91058 Erlangen, Germany

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2013 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
GVGabor Vinci
Gabor Vinci
SLStefan Lindner
Stefan Lindner
FBFrancesco Barbon
Francesco Barbon
SMSebastian Mann
Sebastian Mann
MHMaximilian Hofmann
Maximilian Hofmann
AKAlexander Kölpin
Alexander Kölpin
A novel remote respiration and heartbeat monitoring sensor is presented. The device is a monostatic radar based on a six-port interferometer operating a continuous-wave signal at 24 GHz and a radiated power of less than 3 $\mu\hbox{W}$ . Minor mechanical movements of the patient's body caused by the respiration as well as hearbeat can be tracked by analyzing the phase modulation of the backscattered signal by means of microwave interferometry with the six-port network. High-distance measurement accuracy in the micrometer scale as well as low system complexity are the benefits of the six-port receiver. To verify the performance of the system, different body areas have been observed by the six-port radar. The proposed system has been tested and validated by measurement results.

16 November 2012 in IEEE Microwave Magazine
Verified
Journal Article
Closed access
GVGabor Vinci
Gabor Vinci
SLStefan Lindner
Stefan Lindner
FBFrancesco Barbon
Francesco Barbon
RWRobert Weigel
Robert Weigel
AKAlexander Kölpin
Alexander Kölpin
Industrial automation today is an essential technology underlying our modern society. Advanced positioning and sensor feedback tasks in automation processes often require distance displacement detection, e.g., to measure and track the movement of robots. Furthermore, the detection of mechanical stress in complex industrial machinery through an accurate vibration analysis is often a task of major interest. Therefore, high-resolution distance measurements with short- and long-range positioning are important for a large number of sensing applications and can also be used as a precondition for vibrometer applications. Several automation technologies rely on high precision positioning sensors to track linear as well as rotational movements of various machinery.

1 June 2012
Verified
Conference Paper
Closed access
FBFrancesco Barbon
Francesco Barbon
GVGabor Vinci
Gabor Vinci
SLStefan Lindner
Stefan Lindner
RWRobert Weigel
Robert Weigel
AKAlexander Kölpin
Alexander Kölpin
Displacement detection and vibration measurements are important requirements for automation and mechanical stress diagnosis in diverse industrial environments. Laser interferometry is a widely used technique for these kinds of measurements since it features high-resolution, wide dynamic range and wide frequency response. Another advantage of the laser interferometry technique is contactless diagnosis/sensing which allows remote operations. However this technique is not suitable in harsh environments for instance with the presence of dust or fog which occur in several industrial production sites. In this paper a new contactless radar based vibration measurement technique is presented. It features an RF frontend based on a passive six-port interferometer working at 24 GHz. A dedicated signal processing unit is also presented. The proposed hardware allows to measure with a position accuracy of 0.5 µm.

1 October 2014
Verified
Conference Paper
Closed access
SLSarah Linz
Sarah Linz
GVGabor Vinci
Gabor Vinci
SLStefan Lindner
Stefan Lindner
SMSebastian Mann
Sebastian Mann
FLFabian Lurz
Fabian Lurz
AKAlexander Kölpin
Alexander Kölpin
Six-port interferometers are of great interest for displacement and vibration measurements in industrial as well as medical applications. However, they show offsets as well as amplitude and phase imbalances in their differential in-phase and quadrature signals, leading to inaccuracies of the measured displacement. If a very slow moving or vibrating target has to be monitored, an additional phase shifter for calibration is needed, so that the system's errors can be compensated. A method for calculation and compensation of errors is presented and a compact and cost-efficient implementation of a phase shifter for 24 GHz Six-port interferometers is shown.

1 June 2013
Verified
Conference Paper
Closed access
SLStefan Lindner
Stefan Lindner
FBF. Barbon
F. Barbon
SMSebastian Mann
Sebastian Mann
GVG. Vinci
G. Vinci
RWRobert Weigel
Robert Weigel
AKAlexander Kölpin
Alexander Kölpin
This publication shows an approach for absolute, unambiguous distance measurements with a Six-Port radar at 24 GHz. Such an interferometric radar has the drawback of ambiguity problem concerning phase, limiting the measuring distance to half of the used wavelength. This can be solved with the presented dual tone system using the resulting beat frequency between two tones to determine an absolute position within even several wavelengths. In the following, this system will be presented along with simulations and measurements proving the concept.

1 January 2015
Verified
Conference Paper
Closed access
FLFabian Lurz
Fabian Lurz
SMSebastian Mann
Sebastian Mann
SLSarah Linz
Sarah Linz
SLStefan Lindner
Stefan Lindner
FBFrancesco Barbon
Francesco Barbon
AKAlexander Kölpin
Alexander Kölpin
This paper presents a low power 24GHz Doppler radar system for presence detection and occupancy monitoring. It is based on a minimalistic hardware approach and is able to wirelessly sense human respiratory signals so that even non-moving persons can be detected. By intermittently measuring, the average power consumption could be significantly reduced down to e.g. 0.2mW for 20 measurements per second. Experiments verify that, due to the short wavelength, the single channel receiver limitations can be neglected when only a detection of human respiratory but no evaluation of the breathing frequency is necessary.