Juan C. Briceño

Juan C. Briceño


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2010 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
CCCamila Irene Castro
Camila Irene Castro
JBJuan C. Briceño
Juan C. Briceño

23 August 2022 in Polymers
Verified
Journal Article
Open access
PDF file
Maria Alejandra Rodriguez SotoMaria Alejandra Rodriguez Soto
Maria Alejandra Rodriguez Soto
CPCamilo A. Polanía-Sandoval
Camilo A. Polanía-Sandoval
AAAndres Mauricio Aragon
Andres Mauricio Aragon
DBDaniel Buitrago
Daniel Buitrago
MVMaría Ayala Velásquez
María Ayala Velásquez
JBJuan C. Briceño
Juan C. Briceño
Vascular grafts (VGs) are medical devices intended to replace the function of a blood vessel. Available VGs in the market present low patency rates for small diameter applications setting the VG failure. This event arises from the inadequate response of the cells interacting with the biomaterial in the context of operative conditions generating chronic inflammation and a lack of regenerative signals where stenosis or aneurysms can occur. Tissue Engineered Vascular grafts (TEVGs) aim to induce the regeneration of the native vessel to overcome these limitations. Besides the biochemical stimuli, the biomaterial and the particular micro and macrostructure of the graft will determine the specific behavior under pulsatile pressure. The TEVG must support blood flow withstanding the exerted pressure, allowing the proper compliance required for the biomechanical stimulation needed for regeneration. Although the international standards outline the specific requirements to evaluate vascular grafts, the challenge remains in choosing the proper biomaterial and manufacturing TEVGs with good quality features to perform satisfactorily. In this review, we aim to recognize the best strategies to reach suitable mechanical properties in cell-free TEVGs according to the reported success of different approaches in clinical trials and pre-clinical trials.

26 March 2019 in Polymers
Verified
Journal Article
Open access
PDF file
JSJulian Serna
Julian Serna
SGSergio Florez Gonzalez
Sergio Florez Gonzalez
VTVivian A. Talero
Vivian A. Talero
JBJuan C. Briceño
Juan C. Briceño
CMCarolina Munoz
Carolina Munoz
Juan CruzJuan Cruz
Juan Cruz
Decellularized extracellular matrices (dECMs) represent a promising alternative as a source of materials to develop scaffolds that closely mimic the native environment of cells. As a result, dECMs have attracted significant attention for their applications in regenerative medicine and tissue engineering. One such application is 3D bioprinting, in which dECMs can be used to prepare bioinks with the biomimicry attributes required for regeneration purposes. Formulating bioinks is, however, challenging, due to difficulties in assuring that the printed materials match the mechanical properties of the tissue which is to be regenerated. To tackle this issue, a number of strategies have been devised, including crosslinking methods, the addition of synthetic materials as excipients, and the use of synthetic matrices for casting. We are particularly interested in extrusion-based 3D bioprinting, mainly due to the ease of rapidly conducting tests for adjusting operating conditions such that the required rheological and mechanical properties are met when using it. Here, we propose a novel bioink that consists of an acid-based precipitation of a small intestinal submucosa (SIS) dECM. The formulated bioink also relies on photocrosslinking reactions to attempt to control gelation and ultimately the mechanical properties of the extruded material. Photoinitiation was explored with the aid of varying concentrations of riboflavin (RF). Manual extrusion and rheological flow tests confirmed the printability and shear-thinning behavior of all formulations. Photocrosslinking reactions, however, failed to promote a substantial increase in gelation, which was attributed to considerable entanglement of undigested collagen molecules. As a result, pendant amine groups thought to be involved in the photo-mediated reactions remain largely inaccessible. In silico computational fluid dynamics (CFD) simulations were implemented to determine shear stress values on the bioink along the exit of the printing nozzle. Moreover, we calculated a stability parameter as a means to estimate changes in the bioink stability during the extrusion process. Future studies should be directed toward assessing the role of temperature-induced gelation in the rheological properties of the bioink and the development of strategies to improve the efficiency of photocrosslinking processes.

12 November 2021 in Cells
Verified
Journal Article
Open access
PDF file
Maria Alejandra Rodriguez SotoMaria Alejandra Rodriguez Soto
Maria Alejandra Rodriguez Soto
NVNatalia Suárez Vargas
Natalia Suárez Vargas
Alejandra RiverosAlejandra Riveros
Alejandra Riveros
CMCarolina Munoz
Carolina Munoz
Juan CruzJuan Cruz
Juan Cruz
JBJuan C. Briceño
Juan C. Briceño
Vascular grafts (VG) are medical devices intended to replace the function of a diseased vessel. Current approaches use non-biodegradable materials that struggle to maintain patency under complex hemodynamic conditions. Even with the current advances in tissue engineering and regenerative medicine with the tissue engineered vascular grafts (TEVGs), the cellular response is not yet close to mimicking the biological function of native vessels, and the understanding of the interactions between cells from the blood and the vascular wall with the material in operative conditions is much needed. These interactions change over time after the implantation of the graft. Here we aim to analyze the current knowledge in bio-molecular interactions between blood components, cells and materials that lead either to an early failure or to the stabilization of the vascular graft before the wall regeneration begins.

24 May 2017 in International Journal of Polymeric Materials and Polymeric Biomaterials
Verified
Journal Article
Closed access
LPLaura Milena Pinzón
Laura Milena Pinzón
FCFrancisco Javier Cedano
Francisco Javier Cedano
CCCamila Irene Castro
Camila Irene Castro
JBJuan C. Briceño
Juan C. Briceño
JRJuan Pablo Pablo Casas Rodriguez
Juan Pablo Pablo Casas Rodriguez
FSFelipe Salcedo
Felipe Salcedo
The effects of the addition of calcium carbonate (CC) and hydroxyapatite (HA) in chitosan-based biocomposites were studied keeping in mind their potential use as bone adhesives. The formation of coordination bonds between calcium ions and chitosan amino groups was evident, producing ionic cross-links between chitosan macromolecules, which changed chitosan gelation mechanisms, gel strengths, and adhesiveness into bone surfaces; CC concentration is a key factor in these phenomena. A formulation with 2% chitosan and 4% of both CC and HA showed the most promising performance having high levels of adhesion to bone surfaces (0.27 MPa) and a cohesive mode of failure. GRAPHICAL ABSTRACT

17 April 2017 in Journal of Investigative Surgery
Verified
Journal Article
Closed access
KRKaren Tatiana Valencia Rivero
Karen Tatiana Valencia Rivero
JEJuliana Jaramillo Escobar
Juliana Jaramillo Escobar
SFSergio David Galvis Forero
Sergio David Galvis Forero
MSMaria Clara Miranda Saldaña
Maria Clara Miranda Saldaña
RPRocío del Pilar López Panqueva
Rocío del Pilar López Panqueva
JBJuan C. Briceño
Juan C. Briceño
The purpose of this study was to evaluate a suitable animal model for the in vivo evaluation of patency and vascular tissue regeneration in small intestinal submucosa (SIS) vascular grafts for hemodialysis access. First, a 4-mm U-shaped SIS vascular graft was implanted between the internal carotid artery (CA) and the external jugular vein (JV) in five sheep and six swine. The U-shape grafts remained functional for 53 ± 4 days in sheep and 32 ± 2 days in swine. The sheep model presented exaggerated inflammation, so the swine model was selected for the in vivo study. Based on these initial results, a 4-mm C-shape SIS vascular graft with SIS circumferential reinforcement was developed to mechanically improve the vascular graft and manage complications identified during surgery in both sheep and swine. The C-shape vascular graft was implanted in a swine model (n = 3) between the CA and JV. GORE-TEX® vascular grafts were used as controls in the contralateral side of the neck. C-shape grafts remained patent for 47 ± 4 days, whereas the GORE-TEX® grafts were patent for 30 ± 15 days. The C-shape vascular graft was easier to handle during surgery, and its circumferential reinforcement improved in vivo patency, avoiding kinks in the graft after implantation. Histological results showed neovascularization and some regeneration with the alignment of endothelial cells in the vascular wall of the grafts. The model developed may be helpful in other research involving in vivo studies of vascular grafts for hemodialysis access.