Alejandra Riveros

Ms. Alejandra Riveros

Universidad de Los Andes (Bogotá-Colombia)
+1
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 November 2021 in Cells
Verified
Journal Article
Open access
PDF file
Maria Alejandra Rodriguez SotoMaria Alejandra Rodriguez Soto
Maria Alejandra Rodriguez Soto
NVNatalia Suárez Vargas
Natalia Suárez Vargas
Alejandra RiverosAlejandra Riveros
Alejandra Riveros
CMCarolina Munoz
Carolina Munoz
Juan CruzJuan Cruz
Juan Cruz
JBJuan C. Briceño
Juan C. Briceño
Vascular grafts (VG) are medical devices intended to replace the function of a diseased vessel. Current approaches use non-biodegradable materials that struggle to maintain patency under complex hemodynamic conditions. Even with the current advances in tissue engineering and regenerative medicine with the tissue engineered vascular grafts (TEVGs), the cellular response is not yet close to mimicking the biological function of native vessels, and the understanding of the interactions between cells from the blood and the vascular wall with the material in operative conditions is much needed. These interactions change over time after the implantation of the graft. Here we aim to analyze the current knowledge in bio-molecular interactions between blood components, cells and materials that lead either to an early failure or to the stabilization of the vascular graft before the wall regeneration begins.

10 March 2022 in Cells
Verified
Journal Article
Open access
PDF file
Maria Alejandra Rodriguez SotoMaria Alejandra Rodriguez Soto
Maria Alejandra Rodriguez Soto
Alejandra RiverosAlejandra Riveros
Alejandra Riveros
NVNatalia Suárez Vargas
Natalia Suárez Vargas
Andres J. Garcia-BrandAndres J. Garcia-Brand
Andres J. Garcia-Brand
CMCarolina Munoz
Carolina Munoz
JBJuan C. Briceño
Juan C. Briceño
Tissue-engineered vascular grafts (TEVGs) are a promising alternative to treat vascular disease under complex hemodynamic conditions. However, despite efforts from the tissue engineering and regenerative medicine fields, the interactions between the material and the biological and hemodynamic environment are still to be understood, and optimization of the rational design of vascular grafts is an open challenge. This is of special importance as TEVGs not only have to overcome the surgical requirements upon implantation, they also need to withhold the inflammatory response and sustain remodeling of the tissue. This work aims to analyze and evaluate the bio-molecular interactions and hemodynamic phenomena between blood components, cells and materials that have been reported to be related to the failure of the TEVGs during the regeneration process once the initial stages of preimplantation have been resolved, in order to tailor and refine the needed criteria for the optimal design of TEVGs.

24 May 2022 in Polymers
Verified
Journal Article
Open access
PDF file
Maria Alejandra Rodriguez SotoMaria Alejandra Rodriguez Soto
Maria Alejandra Rodriguez Soto
Andres J. Garcia-BrandAndres J. Garcia-Brand
Andres J. Garcia-Brand
Alejandra RiverosAlejandra Riveros
Alejandra Riveros
NVNatalia Suárez Vargas
Natalia Suárez Vargas
FSFidel Serrano
Fidel Serrano
JBJuan C. Briceño
Juan C. Briceño
Fabrication of scaffolds with hierarchical structures exhibiting the blood vessel topological and biochemical features of the native extracellular matrix that maintain long-term patency remains a major challenge. Within this context, scaffold assembly using biodegradable synthetic polymers (BSPs) via electrospinning had led to soft-tissue-resembling microstructures that allow cell infiltration. However, BSPs fail to exhibit the sufficient surface reactivity, limiting protein adsorption and/or cell adhesion and jeopardizing the overall graft performance. Here, we present a methodology for the fabrication of three-layered polycaprolactone (PCL)-based tubular structures with biochemical cues to improve protein adsorption and cell adhesion. For this purpose, PCL was backbone-oxidized (O-PCL) and cast over a photolithography-manufactured microgrooved mold to obtain a bioactive surface as demonstrated using a protein adsorption assay (BSA), Fourier transform infrared spectroscopy (FTIR) and calorimetric analyses. Then, two layers of PCL:gelatin (75:25 and 95:5 w/w), obtained using a novel single-desolvation method, were electrospun over the casted O-PCL to mimic a vascular wall with a physicochemical gradient to guide cell adhesion. Furthermore, tensile properties were shown to withstand the physiological mechanical stresses and strains. In vitro characterization, using L929 mouse fibroblasts, demonstrated that the multilayered scaffold is a suitable platform for cell infiltration and proliferation from the innermost to the outermost layer as is needed for vascular wall regeneration. Our work holds promise as a strategy for the low-cost manufacture of next-generation polymer-based hierarchical scaffolds with high bioactivity and resemblance of ECM’s microstructure to accurately guide cell attachment and proliferation.

Verified
Journal Article
Open access
PDF file
Alejandra RiverosAlejandra Riveros
Alejandra Riveros
Andres J. Garcia-BrandAndres J. Garcia-Brand
Andres J. Garcia-Brand
Maria Alejandra Rodriguez SotoMaria Alejandra Rodriguez Soto
Maria Alejandra Rodriguez Soto
NSNESTOR SANDOVAL
NESTOR SANDOVAL
CMCarolina Munoz
Carolina Munoz
JBJuan C. Briceño
Juan C. Briceño
Currently available small diameter vascular grafts (<6 mm) present several long-term limitations, which has prevented their full clinical implementation. Computational modeling and simulation emerge as tools to study and optimize the rational design of small diameter tissue engineered vascular grafts (TEVG). This study aims to model the correlation between mechanical-hemodynamic-biochemical variables on protein adsorption over TEVG and their regenerative potential. To understand mechanical-hemodynamic variables, two-way Fluid-Structure Interaction (FSI) computational models of novel TEVGs were developed in ANSYS Fluent 2019R3® and ANSYS Transient Structural® software. Experimental pulsatile pressure was included as an UDF into the models. TEVG mechanical properties were obtained from tensile strength tests, under the ISO7198:2016, for novel TEVGs. Subsequently, a kinetic model, linked to previously obtained velocity profiles, of the protein-surface interaction between albumin and fibrinogen, and the intima layer of the TEVGs, was implemented in COMSOL Multiphysics 5.3®. TEVG wall properties appear critical to understand flow and protein adsorption under hemodynamic stimuli. In addition, the kinetic model under flow conditions revealed that size and concentration are the main parameters to trigger protein adsorption on TEVGs. The computational models provide a robust platform to study multiparametrically the performance of TEVGs in terms of protein adsorption and their regenerative potential.

22 September 2020 in Processes
Verified
Journal Article
Open access
PDF file
Alejandra RiverosAlejandra Riveros
Alejandra Riveros
MCMonica Cuellar
Monica Cuellar
PSPaolo F. Sánchez
Paolo F. Sánchez
CMCarolina Munoz
Carolina Munoz
Juan CruzJuan Cruz
Juan Cruz
JBJuan C. Briceño
Juan C. Briceño
Currently available small diameter vascular conduits present several long-term limitations, which has prevented their full clinical implementation. Commercially available vascular grafts show no regenerative capabilities and eventually require surgical replacement; therefore, it is of great interest to develop alternative regenerative vascular grafts (RVG). Decellularized Small Intestinal Submucosa (SIS) is an attractive material for RVG, however, the evaluation of the performance of these grafts is challenging due to the absence of devices that mimic the conditions found in vivo. Thereby, the objective of this study is to design, manufacture and validate in silico and in vitro, a novel fluidic system for the evaluation of human umbilical vein endothelial cells (HUVECs) proliferation on SIS-based RVG under dynamical conditions. Our perfusion and rotational fluidic system was designed in Autodesk Inventor 2018. In silico Computational Fluid Dynamics (CFD) validation of the system was carried out using Ansys Fluent software from ANSYS, Inc for dynamical conditions of a pulsatile pressure function measured experimentally over a rigid wall model. Mechanical and biological parameters such as flow regime, pressure gradient, wall shear stress (WSS), sterility and indirect cell viability (MTT assay) were also evaluated. Cell adhesion was confirmed by SEM imaging. The fluid flow regime within the system remains laminar. The system maintained sterility and showed low cytotoxicity levels. HUVECs were successfully cultured on SIS-based RVG under both perfusion and rotation conditions. In silico analysis agreed well with our experimental and theoretical results, and with recent in vitro and in vivo reports for WSS. The system presented is a tool for evaluating RVG and represents an alternative to develop new methods and protocols for a more comprehensive study of regenerative cardiovascular devices.

1 May 2018
Verified
Conference Paper
Closed access
JCJose Corredor
Jose Corredor
VAValentina Ardila
Valentina Ardila
VHViviana Hernandez
Viviana Hernandez
Alejandra RiverosAlejandra Riveros
Alejandra Riveros
The synthesis of silver nanoparticles has increased in recent years due to the numerous applications of these in various biotechnological and biomedical fields, such as industrial additives, immobilization of proteins, orthopedic implants, healing, virus inhibitors, etc. In the present study, the synthesis of silver nanoparticles was made from the reducing activity of the fungus Fusarium oxysporum, when suspended in a solution of silver nitrate biomass, where the effect of the availability of nitrogen on the substrate was evaluated, the time of incubation and the saturation of the silver nitrate solution, to evaluate the effect of said factors in the optimization of nanoparticle synthesis. The optical density of the suspension obtained was considered as a response variable to determine the concentration of nanoparticles produced. Finally, it is concluded that the most influential combination of factors in the production of silver nanoparticles corresponds to the interaction between the incubation time of the fungus and the availability of nitrogen; in the same way it is determined that the least influential factor corresponds to the saturation of the silver nitrate solution.