Vincent Walter

Dr. Vincent Walter

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2020 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
TRToky Harrison RABENIMANANA
Toky Harrison RABENIMANANA
VWVincent Walter
Vincent Walter
Najib KacemNajib Kacem
Najib Kacem
PMPatrice Le Moal
Patrice Le Moal
GBGilles Bourbon
Gilles Bourbon
JLJoseph Lardiès
Joseph Lardiès
In order to overcome mode aliasing limitation in linear mode-localized sensors, we demonstrate in this Letter both theoretically and experimentally how to tune the electrostatic nonlinearity and exceed the ultimate sensitivity reachable in the linear regime. A mass sensor composed of two coupled micro-cantilevers with different lengths is considered and the results show that the sensitivity can be significantly enhanced up to 67 % . By performing experiments on the fabricated device and depositing the mass perturbation with a focused ion beam, the same phenomenon was observed. These promising results open the way toward ultrasensitive multimodal microsensors with functionalized nonlinearities.

16 June 2021 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
TRToky Harrison RABENIMANANA
Toky Harrison RABENIMANANA
VWVincent Walter
Vincent Walter
Najib KacemNajib Kacem
Najib Kacem
PMPatrice Le Moal
Patrice Le Moal
GBGilles Bourbon
Gilles Bourbon
JLJoseph Lardies
Joseph Lardies
This letter demonstrates the linear dynamic range enhancement of a mode-localized microelectromechanical systems sensor based on two weakly coupled cantilevers under electrostatic actuation resulting in a repulsive force. An analytical model is proposed to design the sensor, and the expression of the electrostatic force is obtained using a finite element simulation. Compared to attractive electrostatic actuation, the intensity of the resulting force is less sensitive to the change in the cantilever’s displacement, with negligible electrostatic nonlinearities. This result is confirmed by experimental measurements showing linear vibrations up to 70% of the gap, which is almost three times higher than the electrostatic critical amplitude of a similar device using attractive electrostatic force. Finally, the mass sensing capability is highlighted by depositing a few picograms of platinum on the sensor.

1 October 2017 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
AGAyrat Galisultanov
Ayrat Galisultanov
PMPatrice Le Moal
Patrice Le Moal
GBGilles Bourbon
Gilles Bourbon
VWVincent Walter
Vincent Walter

13 July 2022 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
TRToky Harrison RABENIMANANA
Toky Harrison RABENIMANANA
FNFehmi Najar
Fehmi Najar
Mehdi GhommemMehdi Ghommem
Mehdi Ghommem
VWVincent Walter
Vincent Walter
Najib KacemNajib Kacem
Najib Kacem
In this work, we consider MEMS devices made of mechanically coupled microbeams under electric actuation. We conduct an experimental study to identify the occurrence of veering and then investigate its dynamic response for different electric actuations. A slight change in the DC voltage bias from the veering point is observed to affect significantly the frequency response. Indeed, jump to large orbits occurred when perturbing the applied DC voltage while operating near the cyclic-fold bifurcation point. We also develop and validate a mathematical model to simulate the response of the device. The model showed similarities in the softening effect of the DC voltage bias and an added mass when matching their induced shift in the natural frequency. As such, one can discern the inherent nonlinear effects of DC voltage bias on coupled resonators and exploit them for mass sensing applications without going over the hassle of mass deposition, which requires the deployment of complex processes. We also investigate different mass detection mechanisms. We show the potential of mode localization and the significant and abrupt jumps in the deflection of the coupled microbeams due to mass perturbation to enhance the sensitivity of MEMS mass sensors.

28 May 2003 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
VWVincent Walter
Vincent Walter
PDP. Delobelle
P. Delobelle
PMP. Le Moal
P. Le Moal
Motivated by experimental observations made on soft-PZT/alumina cantilever bimorphs, a nonlinear electromechanical model is presented describing the characteristic phenomena of ferroelectricity: the dielectric hysteresis, the butterfly loop, and the ferroelastic hysteresis. This model uses a phenomenological formulation, written within the general framework of thermodynamics of irreversible processes. The one-dimensional formulation of the model is successfully validated using experimental data from the literature. The model is used to predict the electromechanical behavior of a PZT/alumina cantilever bimorph. The results of the simulations are very promising.

16 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
CHClaude Humbert
Claude Humbert
VWVincent Walter
Vincent Walter
Najib KacemNajib Kacem
Najib Kacem
Therese LebloisTherese Leblois
Therese Leblois
We present a mode localized mass sensor prototype based on a hybrid system excited at a fixed frequency slightly below the resonances. Indeed, we show, both theoretically and experimentally, that this condition yields higher sensitivities and similar sensitivity ranges than that of resonance peak tracking while being less time consuming than a classical open-loop configuration due to the absence of frequency sweep. The system is made of a quartz resonator and a hardware that includes a resonator and the coupling. The digital aspect allows maximum sensitivity to be achieved with a fine tuning of the different parameters and the implementation of a coupling, regardless of the physical resonator geometry. This allows the generation of mode localization on shear waves resonant structures such as the quartz cristal microbalance widely used in biosensing. This solution has been successfully implemented using resin micro balls depositions. The sensitivities reach almost their maximum theoretical values which means this fixed frequency method has the potential to reach lower limit of detection than the open loop frequency tracking method.