Toky Harrison RABENIMANANA

Dr. Toky Harrison RABENIMANANA


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2020 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
TRToky Harrison RABENIMANANA
Toky Harrison RABENIMANANA
VWVincent Walter
Vincent Walter
Najib KacemNajib Kacem
Najib Kacem
PMPatrice Le Moal
Patrice Le Moal
GBGilles Bourbon
Gilles Bourbon
JLJoseph Lardiès
Joseph Lardiès
In order to overcome mode aliasing limitation in linear mode-localized sensors, we demonstrate in this Letter both theoretically and experimentally how to tune the electrostatic nonlinearity and exceed the ultimate sensitivity reachable in the linear regime. A mass sensor composed of two coupled micro-cantilevers with different lengths is considered and the results show that the sensitivity can be significantly enhanced up to 67 % . By performing experiments on the fabricated device and depositing the mass perturbation with a focused ion beam, the same phenomenon was observed. These promising results open the way toward ultrasensitive multimodal microsensors with functionalized nonlinearities.

26 June 2024 in Mechanical Systems and Signal Processing
Verified
Journal Article
Closed access
FNFehmi Najar
Fehmi Najar
Mehdi GhommemMehdi Ghommem
Mehdi Ghommem
TRToky Harrison RABENIMANANA
Toky Harrison RABENIMANANA
MHMohamed Hemid
Mohamed Hemid
VWVincent Walter
Vincent Walter
Najib KacemNajib Kacem
Najib Kacem

16 June 2021 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
TRToky Harrison RABENIMANANA
Toky Harrison RABENIMANANA
VWVincent Walter
Vincent Walter
Najib KacemNajib Kacem
Najib Kacem
PMPatrice Le Moal
Patrice Le Moal
GBGilles Bourbon
Gilles Bourbon
JLJoseph Lardies
Joseph Lardies
This letter demonstrates the linear dynamic range enhancement of a mode-localized microelectromechanical systems sensor based on two weakly coupled cantilevers under electrostatic actuation resulting in a repulsive force. An analytical model is proposed to design the sensor, and the expression of the electrostatic force is obtained using a finite element simulation. Compared to attractive electrostatic actuation, the intensity of the resulting force is less sensitive to the change in the cantilever’s displacement, with negligible electrostatic nonlinearities. This result is confirmed by experimental measurements showing linear vibrations up to 70% of the gap, which is almost three times higher than the electrostatic critical amplitude of a similar device using attractive electrostatic force. Finally, the mass sensing capability is highlighted by depositing a few picograms of platinum on the sensor.

13 July 2022 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
TRToky Harrison RABENIMANANA
Toky Harrison RABENIMANANA
FNFehmi Najar
Fehmi Najar
Mehdi GhommemMehdi Ghommem
Mehdi Ghommem
VWVincent Walter
Vincent Walter
Najib KacemNajib Kacem
Najib Kacem
In this work, we consider MEMS devices made of mechanically coupled microbeams under electric actuation. We conduct an experimental study to identify the occurrence of veering and then investigate its dynamic response for different electric actuations. A slight change in the DC voltage bias from the veering point is observed to affect significantly the frequency response. Indeed, jump to large orbits occurred when perturbing the applied DC voltage while operating near the cyclic-fold bifurcation point. We also develop and validate a mathematical model to simulate the response of the device. The model showed similarities in the softening effect of the DC voltage bias and an added mass when matching their induced shift in the natural frequency. As such, one can discern the inherent nonlinear effects of DC voltage bias on coupled resonators and exploit them for mass sensing applications without going over the hassle of mass deposition, which requires the deployment of complex processes. We also investigate different mass detection mechanisms. We show the potential of mode localization and the significant and abrupt jumps in the deflection of the coupled microbeams due to mass perturbation to enhance the sensitivity of MEMS mass sensors.

19 November 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
TRToky Harrison RABENIMANANA
Toky Harrison RABENIMANANA
VWVincent Walter
Vincent Walter
Najib KacemNajib Kacem
Najib Kacem
PMPatrice Le Moal
Patrice Le Moal
JLJoseph Lardies
Joseph Lardies
This paper presents a nonlinear analytical model of MEMS mass sensor, which is composed of two cantilevers of 98 µm and 100 µm length, 20 µm width and 1.3 µm thick. They are connected by a coupling beam and only the shortest cantilever is actuated by a combined AC-DC voltage. The DC voltage is used to equilibrate the system and the phenomenon of mode localization is investigated when a mass perturbation is applied. The sensor is modeled as a continuous system with beam theory and non-ideal boundary conditions are considered by using flexible supports. With a low AC voltage of 10 mV, a DC voltage of 5.85 V can counterbalance the length difference. This DC voltage decreases at 5.60 V when we increase the AC voltage, due to the effect of electrostatic nonlinearities. For a relative added mass of 0.1%, the amplitude change in the two cantilevers is more important when the coupling is weaker.

18 August 2019
Verified
Conference Paper
Closed access
TRToky Harrison RABENIMANANA
Toky Harrison RABENIMANANA
VWVincent Walter
Vincent Walter
Najib KacemNajib Kacem
Najib Kacem
PMPatrice Le Moal
Patrice Le Moal
GBGilles Bourbon
Gilles Bourbon
JLJoseph Lardiès
Joseph Lardiès
This paper investigates the mass sensing in a mode-localized sensor composed of two weakly coupled MEMS cantilevers with lengths 98μm and 100μm. The two resonators are connected by a coupling beam near the fixed end, and the shortest cantilever is electrostatically actuated with a combined AC-DC voltage. The DC actuation voltage is tuned to compensate the length difference and geometrical imperfections in order to dynamically equilibrate the system. An analytical model of the device using the Euler Bernoulli beam theory is presented and the required DC voltage to reach the balanced state is used. A mass perturbation is then added on the long cantilever and the eigenstate shifts and amplitude ratios in each mode are calculated for different couplings. Results show that the amplitude ratio of the second mode is the best output metric for the mass detection. For the validation of the model, an experimental investigation is carried out by using devices fabricated with the Multi-User MEMS Processes. Three different couplings are considered and the long cantilever is designed with a mass attached at its end. Instead of adding a mass on the device, we remove this part with a probe to introduce the perturbation. When the mass is removed, the experimental frequency responses of the device show localized vibrations, which are in good agreement with the theoretical results.