Halina Garbalinska

Prof. Dr. Halina Garbalinska

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 March 2011 in Heat and Mass Transfer
Verified
Journal Article
Closed access
PDF file
ASA. Siwińska
A. Siwińska
HGHalina Garbalinska
Halina Garbalinska

1 December 2018 in Journal of Materials in Civil Engineering
Verified
Journal Article
Closed access
HGHalina Garbalinska
Halina Garbalinska
JSJarosław Strzałkowski
Jarosław Strzałkowski
The thermal and strength properties and microstructural characteristics of lightweight composites composed of cement matrices aerated by various methods are evaluated. The influence of methods that increase the overall porosity of the cement composites and their overall effect on the thermal and strength properties of the composites are discussed. The porosity of the composites was increased using either an air-entraining admixture, reactive aluminum powder, or aerogel particles. The porosity distribution graphs determined by using mercury and optical porosimetry are presented. A discussion on the technical difficulties that arise during porosity evaluation of the composites with aerogel additive is reviewed. The increased porosity of individual composites results in a significant reduction of the thermal conductivity coefficients, λ . Relatively low values of λ were observed in concretes aerated with the air-entraining admixture and with aerogel particles. Simultaneously, none of the composites showed any significant decrease of the volumetric specific heat, cv . However, aeration of the composites brought about a strong reduction of the compressive strength. The biggest drops were observed for the concretes with air-entraining admixture.

12 October 2016 in Heat and Mass Transfer
Verified
Journal Article
Open access
PDF file
A(Agata Stolarska (Siwińska)
Agata Stolarska (Siwińska)
HGHalina Garbalinska
Halina Garbalinska
This paper presents results of tests and studies conducted on six common building materials, used for constructing and finishing of external walls. These included: ceramic brick, silicate brick, autoclaved aerated concrete, cement mortar, cement–lime mortar and cement mortar modified with polypropylene fibers. Each of these materials is distinguished by the other structure of porousness, affecting both the course of sorption processes and the isotherms obtained. At first, measurements of moisture sorption kinetics at temperatures of 5, 20 and 35 °C were performed, each time at six levels of relative humidity. Then, when the sorption processes expired, equilibrium moisture sorption values were determined for the materials in 18 individual temperature and humidity conditions. The experimental data were used to determine the sorption isotherm courses for each material at the three temperatures. Then, theoretical analysis was performed in order to determine, which of the models available in the literature described the sorption isotherms of the concerned building materials the best. For each material and each of the three temperature values, twenty-four equations were tested. In each case, those of them were identified which ensured the best matching between the theoretical courses and the experimental data. The obtained results indicate that the Chen’s model proved to be the most versatile. It ensured a detailed description of the sorption isotherms for each material and temperature tested.

19 June 2020 in Materials
Verified
Journal Article
Open access
PDF file
JSJarosław Strzałkowski
Jarosław Strzałkowski
HGHalina Garbalinska
Halina Garbalinska
The paper examines the impact of aggregate shape on the compressive strength and thermal properties of concretes with silica fume based on two different aggregates: natural round gravel aggregate and crushed basalt aggregate. Compressive strength and thermal properties of individual concretes were determined during the first year of specimens curing. Additionally, porosity tests were conducted using mercury intrusion porosimetry and optical porosimetry. Mercury porosimetry tests showed that the use of silica fume led to a decrease in the content of pores of size smaller than 0.15 µm compared to the reference concretes without the addition of silica fume. However, tests carried out on crushed basalt-based concrete showed the presence of numerous additional pores with diameters ranging from 0.05 to 300 μm. In case of natural round gravel aggregate-based concrete, the addition of silica fume brought about an increase in its compressive strength. In turn, basalt-based concrete exhibited notably lower compressive strength values due to significantly higher porosity within the range of more than 70 μm. In basalt concrete, the obtained λ values are much lower than in concretes with normal gravel aggregate. In addition, the specific porosity structure had its impact on the process of drying of specimens of each group which occurred at a significantly faster rate in the basalt-based concrete. In conclusion, it can be stated that the use of crushed basalt aggregate causes a significant aeration of concrete, even despite the use of silica fume. As a result, the concrete based on crushed aggregate is characterized by a definitely lower compressive strength, but also better thermal insulation properties compared to analogous concrete made on natural round gravel aggregate.

20 October 2021 in Materials
Verified
Journal Article
Open access
PDF file
HGHalina Garbalinska
Halina Garbalinska
MBMagdalena Bochenek
Magdalena Bochenek
MSMarcin Stasiak
Marcin Stasiak
The thermal and moisture properties of building envelope materials determine their performance over many years of use. Moisture has a particularly negative impact, impairing all the technical parameters and adversely affecting the microclimatic conditions inside the building. This article presents research and analysis on the moisture behavior of partitions made of autoclaved aerated concrete. Autoclaved aerated concrete is a very popular material for building external walls because of its relatively good thermal insulation and sufficient strength, if it is not subjected to increased moisture. This study investigated how the moisture content of this material changes with the change in relative air humidity. The four most popular density classes were studied. The sorption isotherms were determined by the static gravimetric method throughout the whole hygroscopic range. Moreover, the applicability of various models to describe sorption isotherms of this material group has been extensively evaluated. The tested models (Peleg, Redlich, Chen, Oswin, Henderson, Lewicki, Caurie, and GAB) all provided a very good fit with the experimental results for the tested material group (R2 ranged from 0.9599 to 0.9978). This paper indicates that the use of two additional approximation parameters (SSE and RMSE) allows a more precise assessment of the quality of individual models.

22 May 2023 in Journal of Building Engineering
Verified
Journal Article
Open access
Agnieszka ŚlosarczykAgnieszka Ślosarczyk
Agnieszka Ślosarczyk
HGHalina Garbalinska
Halina Garbalinska
JSJarosław Strzałkowski
Jarosław Strzałkowski