Agata Stolarska (Siwińska)

Dr. Agata Stolarska (Siwińska)

West Pomeranian University of Technology in Szczecin, Poland
+1
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 September 2020 in Materials
Verified
Journal Article
Open access
PDF file
A(Agata Stolarska (Siwińska)
Agata Stolarska (Siwińska)
JSJarosław Strzałkowski
Jarosław Strzałkowski
This study examines the thermal parameters of mortars based on different cement type and water-cement W/C ratios. The presented relationships are important from the point of view of thermal insulation of the entire building component, of which the mortar is a part. The thermal properties of the mortar, and in particular its dependence on the degree of moisture, is important information from the point of view of hygrothermal simulations of building components. The moisture effect on the thermal properties was tested using nine mortar types. The study consisted of producing nine types of mortar on the basis of three cements (CEM I 42.5R, CEM II A-S 52.5N, CEM III A 42.5N). For each cement type, three variants of specimens were prepared which differed according to their water/cement ratio (0.50, 0.55 and 0.60). The main research of thermal parameters was carried out using a non-stationary method based on the analysis of changing heat flux readings. The thermal conductivity, volume-specific heat and thermal diffusivity values were analyzed. The tests performed allowed for determination of the density of specimens, water absorbability and thermal parameters in three water saturation states: dry, natural and wet. Additional microstructural tests were performed using mercury intrusion porosimetry. The obtained parameters were used to determine the relationship between the measured properties. An adverse effect of dampness on the thermal insulation of the studied materials was confirmed. In extreme cases, the increase in thermal conductivity due to material high moisture was 93%. The cement used affects the relationship between the total specific surface area and the W/C ratio. As expected, the total porosity of specimens was higher for mortars with higher W/C ratios. A strong correlation has been demonstrated between the total surface area and thermal conductivity. The opposite results were obtained when assessing the relationship between the total specific surface area and water absorbability. In case of specimens CEM II A-S 52.5N, the relation was the proportional, and in specimens CEM III A 42.5N, the relationship was inversely proportional to the W/C ratio.

12 October 2016 in Heat and Mass Transfer
Verified
Journal Article
Open access
PDF file
A(Agata Stolarska (Siwińska)
Agata Stolarska (Siwińska)
HGHalina Garbalinska
Halina Garbalinska
This paper presents results of tests and studies conducted on six common building materials, used for constructing and finishing of external walls. These included: ceramic brick, silicate brick, autoclaved aerated concrete, cement mortar, cement–lime mortar and cement mortar modified with polypropylene fibers. Each of these materials is distinguished by the other structure of porousness, affecting both the course of sorption processes and the isotherms obtained. At first, measurements of moisture sorption kinetics at temperatures of 5, 20 and 35 °C were performed, each time at six levels of relative humidity. Then, when the sorption processes expired, equilibrium moisture sorption values were determined for the materials in 18 individual temperature and humidity conditions. The experimental data were used to determine the sorption isotherm courses for each material at the three temperatures. Then, theoretical analysis was performed in order to determine, which of the models available in the literature described the sorption isotherms of the concerned building materials the best. For each material and each of the three temperature values, twenty-four equations were tested. In each case, those of them were identified which ensured the best matching between the theoretical courses and the experimental data. The obtained results indicate that the Chen’s model proved to be the most versatile. It ensured a detailed description of the sorption isotherms for each material and temperature tested.

1 November 2015 in Energy Procedia
Verified
Journal Article
Open access
A(Agata Stolarska (Siwińska)
Agata Stolarska (Siwińska)
JSJarosław Strzałkowski
Jarosław Strzałkowski
The article presents the results of measurements and developed on their basis sorption isotherms with mathematical description of the graphs obtained. The research was conducted on samples of three kinds of autoclaved aerated concretes with similar bulk density of approximately 600kg/m3, but provided by different manufacturers. The tested concretes were also different by composition of raw materials. One of the examined concretes had fly ash in its composition. The moisture sorption studies were conducted at temperature 25oC and at six relative humidity levels φ ≈ 11, 33, 53, 75, 84, 97%. The levels of temperature and relative humidity conditions correspond to a typical temperature/humidity conditions in which in practice commonly used autoclaved aerated concretes can be found. The moisture sorption content was obtained after several months of measurements at the equilibrium state. This data was then used to prepare sorption isotherms of the tested materials. The experimentally obtained data were then applied to calculate mathematical description of graphs. For this purpose three commonly known and used equations were applied: equation of Chen Y. and Chen Z., equation of Jovanovič’s for multi-layer adsorption, and Hüttig's equation. Using statistical methods the compliance of the adsorption isotherm equations was compared with experimental data. For that purpose the STATISTICA programme was used. To estimate the coefficients of the equations the authors used one of the programme modules, i.e. the non-linear estimation. To assess how well the data fit a statistical model the coefficient of determination R2 was used

1 October 2017 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
A(Agata Stolarska (Siwińska)
Agata Stolarska (Siwińska)
JSJarosław Strzałkowski
Jarosław Strzałkowski
The article presents results of CFD software aided simulations of a thermal bridge, existing at the wall–slab on ground connection. Calculations were made for different variants of the edge insulation location. Schemes without any edge insulation, with some vertical insulation, horizontal, diagonal, and diagonal combined with insulation used as formwork under the slab on ground were analysed. Each variant was differentiated with boundary conditions for the ground. Vertical borders of the model in the ground, as well as the lower border were described in the first solution as adiabatic, while in the second case, a variable temperature value, depending on the ground depth, was set. For comparison, additional calculations were conducted for non-stationary conditions, in which the initial temperature of the ground was set to the average annual temperature of air. The calculations were based on the location of Szczecin, for which the outside air temperature was set to -16.0°C. Results obtained from the simulation were then used to determine the thermal bridge parameters, in particular, thermal coupling coefficient and linear thermal transmittance. The effect of the set of boundary conditions is clearly seen. In general, for all the five variants, lower values of heat fluxes and linear thermal transmittances were obtained, when variable temperature in the ground was assumed. From the point of view of energy balance, it is more favourable to use the values of ψg obtained when the ground temperature is taken into account. The data breakdown shows that application of the actual temperature distribution in the ground to a model has a strong effect on distribution of the 0.0°C isotherm. The adiabatic model indicates that the ground under the slab freezes, while the model, which takes into account the temperature of the ground, shows that the ground under the floor has positive temperatures and the 0.0°C isotherm reaches only the edge of the outer wall. Moreover, the effect of the adopted ground temperatures on the hygrothermal parameters of the cases in question was demonstrated. The models that take into account the temperature of the ground result in more favourable values than those in the adiabatic models. For non-stationary heat flow conditions, the advantages of the diagonal edge isolation, which caused significant offset of the zero isotherm from the foundations, were presented. Variants of horizontal and diagonal edge insulations eliminate the risk of freezing of the foundation and the ground beneath it.


18 December 2021 in Materials
Verified
Journal Article
Open access
PDF file
A(Agata Stolarska (Siwińska)
Agata Stolarska (Siwińska)
Teresa RucinskaTeresa Rucinska
Teresa Rucinska
The subjects of this study were mortars with varying amounts of recycled ceramic aggregate (RCA). As part of the fine aggregate, the RCA volume share is 10%, 20%, 30%, 50% and 100%. First, fresh mixture parameters were evaluated, such as consistency and air content measurement by pressure method. Next, specimens were molded for compressive strength and flexural strength tests after 7, 28 and 56 days of curing. The thermo-humidity parameters of the composites, i.e., coefficient of capillary action and thermal conductivity coefficient were also investigated using nonstationary method. Sorption kinetics of the mortars at different moisture conditions at 20 °C were also evaluated. Sorption tests were carried out using two methods: TM and DVS. The sorption isotherms were plotted on the basis of equilibrium moisture content for the materials tested. The isotherms obtained by the two methods were evaluated. The results allowed us to draw conclusions on the physical and mechanical parameters of the composites with different amounts of RCA and to evaluate the ability to absorb moisture from the environment by these types of materials. A clear decrease in the compressive strength after 28 days of curing compared to the reference mortar was recorded after using 30% to 100% of RCA (approx. 26% to approx. 39%). Changes in flexural strength were significantly smaller, reaching no more than approx. 7.5%. It was shown that the amount of RCA translates into the ability to sorb moisture, which may affect the application of this type of composites. The amount of RCA translates also into the thermal conductivity coefficient, which decreased with increasing amount of RCA.