We propose the novel integrated modelling procedure 3H-EMC for the determination of the environmental flow in rivers and streams; 3H-EMC combines Hydrological, Hydrodynamic and Habitat modelling with the use of the Environmental Management Classes (EMCs) that are defined by the Global Environmental Flow Calculator. We apply 3H-EMC in the Sperchios River in Central Greece, in which water abstractions for irrigation cause significant environmental impacts. Calculations of the hydrodynamic-habitat model, in which the large and the small chub are the main fish species, suggest discharge values that range from 1.0 m3/s to 4.0 m3/s. However, hydrological modelling indicates that it is practically difficult to achieve discharges that are higher than approximately 1.0-1.5 m3/s. Furthermore, legislation suggests significantly lower values (0.4-0.5 m3/s) that are unacceptable from the ecological point of view. This behaviour shows that a non-integrated approach, which is based only on hydrodynamic-habitat modelling does not necessarily result in realistic environmental flows, and thus an integrated approach is required. We propose the value of 1.0 m3/s as the "optimum" environmental flow for Sperchios River, because (a) it satisfies the habitat requirements, as expressed by the values of weighted useable area that are equal to 2180 and 1964 m2 for the large and small chub, respectively, and correspond to 82 and 95% of their respective maximum values, (b) it is consistent with the requirements of Environmental Classes A and B, whose percentiles are higher than 75% for discharge (77.2%) and for habitat availability (>83.5% for the large chub and >85.0% for the small chub), (c) it is practically achievable from the hydrological point of view, and (d) it is higher than the value proposed by the Greek legislation. The proposed modelling approach can be applied to any river or stream using the same or similar modelling tools, which should be linked via suitable coupling algorithms.
Although various methods are currently available for modelling the habitat preferences of aquatic biota, studies comparing the performance of data-driven habitat models are limited. In this study, we assembled a benthic-macroinvertebrate microhabitat-preference dataset and used it to evaluate the predictive accuracy of regression-based univariate Habitat Suitability Curves (HSC), Boosted Regression Trees (BRT), Random Forests (RF), fuzzy-logic-based models using the weighted average (FLWA), maximum membership (FLMM), mean of maximum (FLM) and centroid (FLC) defuzzification algorithms and fuzzy rule-based Bayesian inference (FRB). The results show that the BRT model was the most accurate, closely followed by RF, FRB, FLM and FLMM while the FLC and FLWA algorithms had the lowest performance. However, due to the imbalanced nature of the dataset and in contrast to the fuzzy rule-based algorithms, the HSC, BRT and RF models failed to accurately predict the habitat suitability in low-scored microhabitats. We conclude that, given balanced datasets, BRT and RF can be effectively used in habitat suitability modelling. For imbalanced datasets, a properly adjusted RF model can be applied but when the input dataset is large enough to provide sufficient data-driven IF–THEN rules to train an FRB, FLMM or FLM algorithm, these models will produce the most accurate predictions.
A mathematical model is applied to the tank of Kipseli in Athens, Greece, which is used for storage, balancing and emergency chlorination. A Flow-Through Curve (FTC) experiment is performed for the initial geometry of the tank. The shape and the characteristics of the FTC show a very poor hydraulic efficiency, with extensive short-circuiting, intense mixing and low detention times. To improve the hydraulic efficiency of the tank the use of four alternative arrangements of guiding walls is examined by the model. Prior to its application, the model is verified by comparing the predicted FTC with the experimental. A satisfactory agreement is observed between the calculated and the experimental curves. Then the model is applied to calculate the flow field and the FTC for the four arrangements. Calculations are compared and the arrangement which shows the highest hydraulic efficiency is proposed for construction.
We pose the following research question, “what are (i) the minimum required computation grid and (ii) the required form of hydrodynamic equations, i.e., shallow water equations (SWE) or diffusion wave equations (DWE), in 2D modeling to minimize the computational time while maintaining an acceptable level of error in the prediction of water depths and the extent of flood inundated areas?”. To answer this question, we apply the HEC-RAS 1D/2D model to simulate a disastrous flash flood in the town of Mandra, in Attica, Greece, in November 2017. HEC-RAS 1D/2D combines 1D modeling in the cross-sections of the two main streams of Mandra with 2D modeling in the rest of the potentially flooded area of the computational domain which has an area equal to 18.36 km2. We perform calculations for 8 scenarios that combined various grid sizes (with approximately 44,000–95,000 control volumes) with the use of the SWE or DWE. We derive the following conclusions: (i) calculated maximum water depths using DWE were equal to 60–65% of the corresponding water depths using SWE, i.e., the DWE significantly underestimated water depths; (ii) calculated total inundation areas using the SWE were approximately 4.9–7.9% larger than the corresponding inundation areas using the DWE; these differences can be considered as acceptable; and (iii) the total computation times using SWE, which ranged from 67 to 127 min, were 60–70% longer than the computation times using DWE.
1 July 2009 in Journal of Environmental Engineering
A computational fluid dynamics (CFD) model is presented and applied in the design of the secondary settling tanks of Psyttalia Wastewater Treatment Plant in Athens, Europe’s largest sewage treatment facility. The tanks are of the Gould Type II consisting of the following regions: an inlet-flocculation chamber with an inlet baffle, two zones of settling separated by an intermediate baffle, an outlet region, and a sludge collection region. The number of tanks and their dimensions were determined with an empirical design procedure. Then, theoretical considerations, information from similar existing tanks, and preliminary CFD calculations were combined to determine the dimensions of the main regions and the positions of the baffles. Finally, detailed CFD calculations were performed to examine the performance of the tanks for various design conditions. Computations showed that the flow in the inlet-flocculation region was completely mixed; while in the settling regions a “three-layer” structure with relatively constant layer heights was observed. CFD results were processed to determine parameters of practical interest, including the heights of the sludge blankets and the effluent suspended solids concentrations; these parameters were correlated satisfactorily with the Hazen number, which is used as a scaling parameter in primary settling tanks.