Water Infrastructure (WI) is one of the most important sectors of Critical Infrastructure (CI); it encompasses drinking water, wastewater, and stormwater. The WI is vulnerable to the effects of Climate Change (CC) that can disrupt its functionality; thus, it needs to be adapted to CC, especially in the Mediterranean region, where these effects are expected to intensify during the twenty-first century. For this adaptation a Climate Risk and Vulnerability Assessment (CRVA) is required in the development of WI to identify the important climate hazards and to recommend the required measures for the adaptation of the WI to these hazards. In the present work, a CRVA methodology is developed and presented based on a literature survey and the relevant European Commission guidelines; it is structured around five key steps: (1) Description of the WI, (2) Climate change assessment, (3) Vulnerability assessment, (4) Risk assessment, and (5) Assessment of adaptation measures. The application of the methodology is illustrated indicatively to a wastewater system in Greece for which preliminary estimations are performed, results are discussed, and conclusions are drawn. The proposed methodology can be modified for application to other sectors of CI; moreover, is a valuable resource in academic curricula and ongoing research initiatives.
We pose the following research question, “what are (i) the minimum required computation grid and (ii) the required form of hydrodynamic equations, i.e., shallow water equations (SWE) or diffusion wave equations (DWE), in 2D modeling to minimize the computational time while maintaining an acceptable level of error in the prediction of water depths and the extent of flood inundated areas?”. To answer this question, we apply the HEC-RAS 1D/2D model to simulate a disastrous flash flood in the town of Mandra, in Attica, Greece, in November 2017. HEC-RAS 1D/2D combines 1D modeling in the cross-sections of the two main streams of Mandra with 2D modeling in the rest of the potentially flooded area of the computational domain which has an area equal to 18.36 km2. We perform calculations for 8 scenarios that combined various grid sizes (with approximately 44,000–95,000 control volumes) with the use of the SWE or DWE. We derive the following conclusions: (i) calculated maximum water depths using DWE were equal to 60–65% of the corresponding water depths using SWE, i.e., the DWE significantly underestimated water depths; (ii) calculated total inundation areas using the SWE were approximately 4.9–7.9% larger than the corresponding inundation areas using the DWE; these differences can be considered as acceptable; and (iii) the total computation times using SWE, which ranged from 67 to 127 min, were 60–70% longer than the computation times using DWE.
The flash flood in the town of Mandra, Attica, in 2017 that had a return period equal to approximately T = 150 years was one of the most disastrous floods in Greece. Four years later, flood protection works designed for T = 50 years were built. In this work, we pose the research question ‘How would this disastrous flood have behaved if flood protection works were built?’ To answer this question, we employed the HEC-RAS 1D/2D model, over a detailed DSM, that we calibrated with field measurements to simulate the flood of 2017. We derived the following conclusions: (1) Flooding of the main streets still occurs with 15–25% lower flow velocities and 19–29% lower water depths. (2) The total extent of the inundation areas is reduced by 17%. (3) Works delay flood arrival by approximately 1.5 hour, thus providing the opportunity for an Early Warning System to respond more effectively.
Water Infrastructure (WI), incorporating water supply, wastewater, and stormwater systems, is vulnerable to climate change impacts that can disrupt their functionality; thus, WI needs to be adapted to climate change. In 2021, the European Commission (EC) released the technical guidelines on “Climate-proofing Infrastructure” that include mitigation and adaptation strategies; these guidelines, and the relevant guides that followed, focus mainly on climate change aspects without examining sufficiently the engineering features of WI that are described mainly in the relevant hydro-environmental research; this research is vast and includes various terminologies and methods for all aspects of climate change adaptation. The adaptation procedure of WI to climate change is improved when this research is known to guidelines’ developers. In the present work, to facilitate this knowledge transfer, we typologize the hydro-environmental research via its classification into five categories that are based on the EC guidelines and then perform a literature review that we present as follows: firstly, we introduce and typologize the climate hazards for WI systems and identify the most common of them in the Mediterranean region that we classify into seven groups; then, we classify the hydro-environmental research into five categories based on the EC guidelines, present the main aspects for each of these categories, discuss the future research; and finally, we summarize the conclusions.
Dam and reservoir (D&R) systems, during their long history, have suffered from hundreds of failures, whose mechanisms have been accelerated by climate change and climate hazards. The following research question is posed: “which are the potentially significant climate hazards of D&R systems?” To answer this question, the vulnerability of D&R systems to climate change is assessed via a typologized methodology that is consistent with the technical guidelines of the European Commission on the climate proofing of infrastructure. The main steps of the methodology, which are (1) a description of the D&R system, (2) climate change assessment, and (3) vulnerability assessment, are performed using literature surveys, expert opinions, and climate models. The methodology is applied to the Almopeos D&R system in Greece, which is in the design stage, and the following conclusions are drawn: (1) the potentially significant groups of climate hazards are (i) temperature increase and extreme heat, (ii) precipitation decrease, aridity, and droughts, and (iii) extreme precipitation and flooding, and (2) the vulnerability assessment identified the climate indicators, the most important effects, and the most vulnerable components of the D&R system that can be used in the risk assessment that follows to identify the significant climate hazards and to propose targeted adaptation strategies to reduce their risks to an acceptable level.
Water Infrastructure (WI) incorporating water supply, wastewater, and stormwater systems is vulnerable to Climate Change (CC) impacts that can disrupt their functionality; thus, WI needs to be adapted to CC. In 2021 the European Commission (EC) released the technical guidelines on “Climate-proofing Infrastructure” that include mitigation and adaptation strategies; these guidelines and the relevant guides that followed, focus mainly on CC aspects without examining sufficiently the engineering features of WI that are described mainly in the relevant hydro-environment research; this research is vast and includes various terminologies and methods for all aspects of CC adaptation. The adaptation procedure of WI to CC can be significantly improved when this research is known to guidelines’ developers. To facilitate this knowledge transfer, we performed a review on the hydro-environmental research that we present in this paper as follows: firstly, we introduce and typologize the climate hazards for WI systems and identify the most important of them in the Mediterranean Region that we classify into seven groups; then, we classify the hydro-environmental research into five categories that is based on the EC guidelines, present the main aspects for each of these categories, discuss the future research, and finally we summarize the conclusions.