Amedeo Manuel Cefalì

Mr. Amedeo Manuel Cefalì

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 June 2021 in Atmosphere
Verified
Journal Article
Open access
PDF file
Domenico CiprianoDomenico Cipriano
Domenico Cipriano
ACAmedeo Manuel Cefalì
Amedeo Manuel Cefalì
MAMarco Allegrini
Marco Allegrini
Uncertainty in the quantification of odour measurements is a difficult (but needed) task. Critical aspects include panel selection (required by dynamic olfactometry), sampling, and stability of the samples. Proficiency tests (PTs) can help evaluate such contributions; however, the classical approach to PTs, in which laboratories analyse real samples taken from the field, are not as applicable in this field, and are often implemented by only using dry gas cylinders containing stable compounds. Consequently, uncertainties related to the sampling activity cannot be assessed. In particular, high odour levels and the presence of water vapour in emission sources can create significative biases due to sampling techniques used and chemical reactions that can occur before analysis. In this work, we present experimental notes, developed using the experimental facility ‘LOOP’, realised at the RSE research centre in Italy, in order to “help” the definition, in an upgraded protocol for implementing PTs for odour determinations. Using this bench loop is advantageous as it involves the possibility of implementing samples in conditions very similar to reality (i.e., high temperatures, high water content, and the presence of chemical interferents).

11 August 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Luca FerreroLuca Ferrero
Luca Ferrero
ABAlessandra Bigogno
Alessandra Bigogno
ACAmedeo Manuel Cefalì
Amedeo Manuel Cefalì
GRGrazia Rovelli
Grazia Rovelli
LDLuca D’angelo
Luca D’angelo
BEbolzacchini ezio
bolzacchini ezio
The role of the elemental carbon (EC), in synergy with hygroscopic ionic species, was investigated to study the formation of electrical bridging phenomena once the aerosol deliquescence is achieved. Ambient aerosol samples were collected on hydrophobic surfaces in urban and rural sites in Northern Italy; their conductance was measured in an Aerosol Exposure Chamber (AEC) while varying the relative humidity. An electric signal was detected on 64% of the collected samples with conductance values (11.20 ± 7.43 μS) above the failure threshold (1 μS) of printed circuit boards. The ionic content was higher for non-electrically conductive samples (43.7 ± 5.6%) than for electrically conductive ones (37.1 ± 5.6%). Conversely, EC was two times higher for electrically conductive samples (26.4 ± 4.1 μg cm−2; 8.4 ± 1.7%) than for non-electrical ones (12.0 ± 4.1 μg cm−2; 5.2 ± 1.9%) suggesting that the synergy between the ionic and carbonaceous fractions is necessary to promote a bridging phenomenon. Synthetic aerosols (EC only, saline only, mixed saline and EC) were generated in laboratory and their conductance was measured in the AEC to verify the ambient results. Only in case of a contemporary presence of both EC and ionic components the bridging phenomenon occurred in keeping with the theoretical deliquescence values of each salt (R2 = 0.996).

9 October 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ACAmedeo Manuel Cefalì
Amedeo Manuel Cefalì
BEbolzacchini ezio
bolzacchini ezio
Luca FerreroLuca Ferrero
Luca Ferrero
GCGiuseppe Clauser
Giuseppe Clauser
CDChristian Dallapiccola
Christian Dallapiccola
Domenico CiprianoDomenico Cipriano
Domenico Cipriano
Formaldehyde (H−CHO) is a chemical compound extremely common in many industrial productions. However, in 2004, it was reclassified as carcinogenic (H350) and mutagenic (H341). Therefore, stringent limitations on emissions were implemented; among them, the lowest limit (3 mg/m3) was adopted by some Italian Local Competent Authorities. Up to now, no European-validated method for emission control was available, and for this reason, a specific working group (WG 40) has been created in the framework of the European Committee for Standardization Technical Committees 264 (CEN TC 264) to publish a qualified method for the quantification of Formaldehyde emissions from stationary sources (i.e., power stations, incinerators, petrochemicals, and industrial plants that uses combustion for their energetic purposes). Some preliminary trial tests were conducted to evaluate (1) the sampling protocol, and (2) the analytical technique. From a measurement perspective, two methods were selected: EPA 323—VDI 3862-6 and VDI 3862-2. Every new method prepared by CEN shall be verified before publication in the field and in real conditions to verify its metrological properties (i.e., precision, biases, reproducibility, and repeatability), costs and the training needs for involved personnel. With this aim, two measuring campaigns were conducted, and some important conclusions emerged concerning the H−CHO sampling procedure. Due to high water levels normally present, condensation during sampling is critical and can cause unpredictable errors; wet traps (impingers) give good responses. The sampling in pure water appeared unstable, but using an H2SO4 solution solved this issue, thus being recommended.

21 November 2024 in Atmosphere
Verified
Journal Article
Open access
PDF file
CFClaudia Franchina
Claudia Franchina
ACAmedeo Manuel Cefalì
Amedeo Manuel Cefalì
MGMartina Gianotti
Martina Gianotti
AFAlessandro Frugis
Alessandro Frugis
CCCorrado Corradi
Corrado Corradi
Domenico CiprianoDomenico Cipriano
Domenico Cipriano
This study evaluated the reliability of an electronic nose in monitoring odour concentration near a wastewater treatment plant and examined the correlation between four sensor readings and odour intensity. The electronic nose chemical sensors are related to the concentration of the following chemical species: two values for the concentration of VOCs recorded via the PID sensor (VPID) and the EC sensor (VEC), and concentrations of sulfuric acid (VH2S) and benzene (VC6H6). Using Random Forest and least squares regression analysis, the study identifies VH2S and VC6H6 as key contributors to odour concentration (CcOD). Three Random Forest models (RF0, RF1, RF2), with different characteristics for splitting between the test set and the training set, were tested, with RF1 showing superior predictive performance due to its training approach. All models highlighted VH2S and VC6H6 as significant predictors, while VPID and VEC had less influence. A significant correlation between odour concentration and specific chemical sensor readings was found, particularly for VH2S and VC6H6. However, predicting odour concentrations below 1000 ouE/m3 proved challenging. Linear regression further confirmed the importance of VH2S and VC6H6, with a moderate R-squared value of 0.70, explaining 70% of the variability in odour concentration. The study demonstrated the effectiveness of combining Random Forest and least squares regression for robust and interpretable results. Future research should focus on expanding the dataset and incorporating additional variables to enhance model accuracy. The findings underscore the necessity of specific sensor training and standardised procedures for accurate odour monitoring and characterisation.

30 November 2023 in Atmosphere
Verified
Journal Article
Open access
PDF file
NLNiccolò Losi Losi
Niccolò Losi Losi
PMPiotr Markuszewski
Piotr Markuszewski
MRMartin Rigler
Martin Rigler
AGAsta Gregoric
Asta Gregoric
Grisa MocnikGrisa Mocnik
Grisa Mocnik
Luca FerreroLuca Ferrero
Luca Ferrero
Light-absorbing aerosols (LAA) impact the atmosphere by heating it. Their effect in the Arctic was investigated during two summer Arctic oceanographic campaigns (2018 and 2019) around the Svalbard Archipelago in order to unravel the differences between the Arctic background and the local anthropic settlements. Therefore, the LAA heating rate (HR) was experimentally determined. Both the chemical composition and high-resolution measurements highlighted substantial differences between the Arctic Ocean background (average eBC concentration of 11.7 ± 0.1 ng/m3) and the human settlements, among which the most impacting appeared to be Tromsø and Isfjorden (mean eBC of 99.4 ± 3.1 ng/m3). Consequently, the HR in Isfjorden (8.2 × 10−3 ± 0.3 × 10−3 K/day) was one order of magnitude higher than in the pristine background conditions (0.8 × 10−3 ± 0.9 × 10−5 K/day). Therefore, we conclude that the direct climate impact of local LAA sources on the Arctic atmosphere is not negligible and may rise in the future due to ice retreat and enhanced marine traffic.

10 November 2026
Verified
Other
Open access
PDF file
IGIrene Gini
Irene Gini
MBMattia Borelli
Mattia Borelli
GPGuido Pirovano
Guido Pirovano
ABAlessandra Balzarini
Alessandra Balzarini
ACAmedeo Manuel Cefalì
Amedeo Manuel Cefalì
Luca FerreroLuca Ferrero
Luca Ferrero
The hygroscopic behavior of atmospheric aerosols is controlled by their chemical composition, which determines phase transitions, water uptake and physical state. Aerosol hydration influences particle size, mass, optical and chemical properties, making it a key process in atmospheric science. This study evaluates the performance of ISORROPIA 2.1, a thermodynamic equilibrium model, in predicting aerosol water uptake across a wide range of aerosol types, including indoor and outdoor (urban, extra-urban and marine) aerosols and deposits on electrical insulators. Inorganic composition was determined by ion chromatography, while deliquescence behavior was experimentally characterized using an Aerosol Exposure Chamber, providing a comprehensive dataset for model validation. ISORROPIA 2.1 accurately reproduces deliquescence relative humidity (DRH) and hygroscopic growth in sulfate–nitrate–ammonium dominated systems, with mean deviations of 4.3 ± 2.6 % RH for the onset of deliquescence (DRHs) and 4.4 ± 3.2 % RH for completion (DRHe). In contrast, ammonium-poor mixtures enriched in alkali and alkaline-earth ions (K+, Mg2+, Ca2+, Na+), including marine aerosol and insulator deposits, show non-physical humidification behavior characterized by discontinuous liquid–solid transitions. These anomalies arise from routine-selection instabilities in dust-rich regimes. Targeted code refinements improved model stability and water-uptake predictions, extending the applicability of ISORROPIA 2.1 to sulfate-poor, sodium- and crustal-rich systems. Overall, this work provides an experimental benchmark for aerosol thermodynamics, identifies the compositional limits of ISORROPIA 2.1 and broadens its applicability to complex inorganic aerosol mixtures.