Domenico Cipriano

Dr. Domenico Cipriano

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2019 in Biosensors
Verified
Journal Article
Open access
PDF file
Domenico CiprianoDomenico Cipriano
Domenico Cipriano
Laura CapelliLaura Capelli
Laura Capelli
Since electronic noses are used more and more for air quality monitoring purposes, and in some countries are starting to have a legal value, there is a need for standardization and programs for the quality verification of instruments. Such quality programs have the aim to guarantee the main characteristics of the instrument for both the final user and local authorities, let the user establish a suitable maintenance procedure and give information on measurement uncertainty. One critical aspect when dealing with electronic noses for environmental odour monitoring is that environmental odours are complex mixtures that are not repeatable nor reproducible, giving that they are not suitable for quality verifications. This paper aims to review and discuss the different approaches that can be adopted in order to perform quality checks on electronic noses (e-noses) used for environmental odour monitoring, thereby referring to existing technical standards, such as the Dutch NTA 9055:2012, the new German VDI 3518-3:2018, and the Italian UNI 1605848 project, which directly refer to electronic noses. Moreover, also the European technical standards that are prescriptive for automatic measuring systems (AMSs) are taken into consideration (i.e., EN 14181:2014 and EN 15267:2009), and their possible applicability to electronic noses is investigated. Finally, the pros and cons of the different approaches are presented and discussed in the conclusions section.

18 October 2024 in Molecules
Verified
Journal Article
Open access
PDF file
Stefano DugheriStefano Dugheri
Stefano Dugheri
GCGiovanni Cappelli
Giovanni Cappelli
NFNiccolò Fanfani
Niccolò Fanfani
Donato SquillaciDonato Squillaci
Donato Squillaci
IRIlaria Rapi
Ilaria Rapi
Nicola MucciNicola Mucci
Nicola Mucci
MonoTrapTM was introduced in 2009 as a novel miniaturized configuration for sorptive sampling. The method for the characterization of volatile organic compound (VOC) emission profiles from hot mix asphalt (HMA) consisted of a two-step procedure: the analytes, initially adsorbed into the coating in no vacuum- or vacuum-assistance mode, were then analyzed following an automated thermal desorption (TD) step. We took advantage of the theoretical formulation to reach some conclusions on the relationship between the physical characteristics of the monolithic material and uptake rates. A total of 35 odor-active volatile compounds, determined by gas chromatography-mass spectrometry/olfactometry analysis, contributed as key odor compounds for HMA, consisting mainly of aldehydes, alcohols, and ketones. Chemometric analysis revealed that MonoTrapTM RGC18-TD was the better coating in terms of peak area and equilibrium time. A comparison of performance showed that Vac/no-Vac ratios increased, about an order of magnitude, as the boiling point of target analytes increased. The innovative hybrid adsorbent of silica and graphite carbon monolith technology, having a large surface area bonded with octadecylsilane, showed effective adsorption capability, especially to polar compounds.

12 June 2021 in Atmosphere
Verified
Journal Article
Open access
PDF file
Domenico CiprianoDomenico Cipriano
Domenico Cipriano
ACAmedeo Manuel Cefalì
Amedeo Manuel Cefalì
MAMarco Allegrini
Marco Allegrini
Uncertainty in the quantification of odour measurements is a difficult (but needed) task. Critical aspects include panel selection (required by dynamic olfactometry), sampling, and stability of the samples. Proficiency tests (PTs) can help evaluate such contributions; however, the classical approach to PTs, in which laboratories analyse real samples taken from the field, are not as applicable in this field, and are often implemented by only using dry gas cylinders containing stable compounds. Consequently, uncertainties related to the sampling activity cannot be assessed. In particular, high odour levels and the presence of water vapour in emission sources can create significative biases due to sampling techniques used and chemical reactions that can occur before analysis. In this work, we present experimental notes, developed using the experimental facility ‘LOOP’, realised at the RSE research centre in Italy, in order to “help” the definition, in an upgraded protocol for implementing PTs for odour determinations. Using this bench loop is advantageous as it involves the possibility of implementing samples in conditions very similar to reality (i.e., high temperatures, high water content, and the presence of chemical interferents).

19 May 2025 in Separations
Verified
Journal Article
Open access
PDF file
Stefano DugheriStefano Dugheri
Stefano Dugheri
GCGiovanni Cappelli
Giovanni Cappelli
Riccardo GoriRiccardo Gori
Riccardo Gori
SZStefano Zampolli
Stefano Zampolli
NFNiccolò Fanfani
Niccolò Fanfani
Nicola MucciNicola Mucci
Nicola Mucci
Background: In response to the growing demand for the real-time, in-field characterization of odorous anthropogenic emissions, this study develops and uses a MEMS-based micropacked thermal desorption Gas Chromatography system coupled with a PhotoIonization Detector (GC/PID) for Hot Mix Asphalt (HMA) plant emissions. Methods: The innovative portable device, Pyxis GC, enables the high-sensitivity profiling of Volatile Organic Compounds (VOCs), particularly aldehydes and ketones, with sub-ppb detection limits using ambient air as the carrier gas. A comprehensive experimental design optimized the preconcentration parameters, resulting in an efficient, green analytical method evaluated via the Green Analytical Procedure Index (GAPI). Sorbent comparison showed quinoxaline-bridged cavitands outperform the conventional materials. Results and conclusions: The method was successfully deployed on site for source-specific sampling at an HMA plant, generating robust emission fingerprints. To assess environmental impact, a Generalized Additive Model (GAM) was developed, incorporating the process temperature and Sum of Odour Activity Values (SOAV) to predict odour concentrations. The model revealed a significant non-linear influence of temperature on emissions and validated its predictive capability despite the limited sample size. This integrated analytical–statistical approach demonstrates the utility of MEMS technology for real-time air quality assessment and odour dispersion modelling, offering a powerful tool for environmental monitoring and regulatory compliance.

9 October 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ACAmedeo Manuel Cefalì
Amedeo Manuel Cefalì
BEbolzacchini ezio
bolzacchini ezio
Luca FerreroLuca Ferrero
Luca Ferrero
GCGiuseppe Clauser
Giuseppe Clauser
CDChristian Dallapiccola
Christian Dallapiccola
Domenico CiprianoDomenico Cipriano
Domenico Cipriano
Formaldehyde (H−CHO) is a chemical compound extremely common in many industrial productions. However, in 2004, it was reclassified as carcinogenic (H350) and mutagenic (H341). Therefore, stringent limitations on emissions were implemented; among them, the lowest limit (3 mg/m3) was adopted by some Italian Local Competent Authorities. Up to now, no European-validated method for emission control was available, and for this reason, a specific working group (WG 40) has been created in the framework of the European Committee for Standardization Technical Committees 264 (CEN TC 264) to publish a qualified method for the quantification of Formaldehyde emissions from stationary sources (i.e., power stations, incinerators, petrochemicals, and industrial plants that uses combustion for their energetic purposes). Some preliminary trial tests were conducted to evaluate (1) the sampling protocol, and (2) the analytical technique. From a measurement perspective, two methods were selected: EPA 323—VDI 3862-6 and VDI 3862-2. Every new method prepared by CEN shall be verified before publication in the field and in real conditions to verify its metrological properties (i.e., precision, biases, reproducibility, and repeatability), costs and the training needs for involved personnel. With this aim, two measuring campaigns were conducted, and some important conclusions emerged concerning the H−CHO sampling procedure. Due to high water levels normally present, condensation during sampling is critical and can cause unpredictable errors; wet traps (impingers) give good responses. The sampling in pure water appeared unstable, but using an H2SO4 solution solved this issue, thus being recommended.

21 November 2024 in Atmosphere
Verified
Journal Article
Open access
PDF file
CFClaudia Franchina
Claudia Franchina
ACAmedeo Manuel Cefalì
Amedeo Manuel Cefalì
MGMartina Gianotti
Martina Gianotti
AFAlessandro Frugis
Alessandro Frugis
CCCorrado Corradi
Corrado Corradi
Domenico CiprianoDomenico Cipriano
Domenico Cipriano
This study evaluated the reliability of an electronic nose in monitoring odour concentration near a wastewater treatment plant and examined the correlation between four sensor readings and odour intensity. The electronic nose chemical sensors are related to the concentration of the following chemical species: two values for the concentration of VOCs recorded via the PID sensor (VPID) and the EC sensor (VEC), and concentrations of sulfuric acid (VH2S) and benzene (VC6H6). Using Random Forest and least squares regression analysis, the study identifies VH2S and VC6H6 as key contributors to odour concentration (CcOD). Three Random Forest models (RF0, RF1, RF2), with different characteristics for splitting between the test set and the training set, were tested, with RF1 showing superior predictive performance due to its training approach. All models highlighted VH2S and VC6H6 as significant predictors, while VPID and VEC had less influence. A significant correlation between odour concentration and specific chemical sensor readings was found, particularly for VH2S and VC6H6. However, predicting odour concentrations below 1000 ouE/m3 proved challenging. Linear regression further confirmed the importance of VH2S and VC6H6, with a moderate R-squared value of 0.70, explaining 70% of the variability in odour concentration. The study demonstrated the effectiveness of combining Random Forest and least squares regression for robust and interpretable results. Future research should focus on expanding the dataset and incorporating additional variables to enhance model accuracy. The findings underscore the necessity of specific sensor training and standardised procedures for accurate odour monitoring and characterisation.