Sotiria D. Psoma

Dr. Sotiria D. Psoma

The Open University
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 July 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
SPSotiria D. Psoma
Sotiria D. Psoma
CKChryso Kanthou
Chryso Kanthou
We present a critical review of the current progress in wearable insulin biosensors. For over 40 years, glucose biosensors have been used for diabetes management. Measurement of blood glucose is an indirect method for calculating the insulin administration dosage, which is critical for insulin-dependent diabetic patients. Research and development efforts aiming towards continuous-insulin-monitoring biosensors in combination with existing glucose biosensors are expected to offer a more accurate estimation of insulin sensitivity, regulate insulin dosage and facilitate progress towards development of a reliable artificial pancreas, as an ultimate goal in diabetes management and personalised medicine. Conventional laboratory analytical techniques for insulin detection are expensive and time-consuming and lack a real-time monitoring capability. On the other hand, biosensors offer point-of-care testing, continuous monitoring, miniaturisation, high specificity and sensitivity, rapid response time, ease of use and low costs. Current research, future developments and challenges in insulin biosensor technology are reviewed and assessed. Different insulin biosensor categories such as aptamer-based, molecularly imprinted polymer (MIP)-based, label-free and other types are presented among the latest developments in the field. This multidisciplinary field requires engagement between scientists, engineers, clinicians and industry for addressing the challenges for a commercial, reliable, real-time-monitoring wearable insulin biosensor.

26 October 2022 in Energies
Verified
Journal Article
Open access
PDF file
ISIhor Sobianin
Ihor Sobianin
SPSotiria D. Psoma
Sotiria D. Psoma
ATAntonios Tourlidakis
Antonios Tourlidakis
Energy harvesters serve as continuous and long-lasting sources of energy that can be integrated into wearable and implantable sensors and biomedical devices. This review paper presents the current progress, the challenges, the advantages, the disadvantages and the future trends of energy harvesters which can harvest energy from various sources from the human body. The most used types of energy are chemical; thermal and biomechanical and each group is represented by several nano-generators. Chemical energy can be harvested with a help of microbial and enzymatic biofuel cells, thermal energy is collected via thermal and pyroelectric nano-generators, biomechanical energy can be scavenged with piezoelectric and triboelectric materials, electromagnetic and electrostatic generators and photovoltaic effect allows scavenging of light energy. Their operating principles, power ratings, features, materials, and designs are presented. There are different ways of extracting the maximum energy and current trends and approaches in nanogenerator designs are discussed. The ever-growing interest in this field is linked to a larger role of wearable electronics in the future. Possible directions of future development are outlined; and practical biomedical applications of energy harvesters for glucose sensors, oximeters and pacemakers are presented. Based on the increasingly accumulated literature, there are continuous promising improvements which are anticipated to lead to portable and implantable devices without the requirement for batteries.

1 December 2010 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
SPSotiria D. Psoma
Sotiria D. Psoma
PWPeter D. van der Wal
Peter D. van der Wal
OFOlivier Frey
Olivier Frey
NRNicolaas F. de Rooij
Nicolaas F. de Rooij
TTTony Turner
Tony Turner

10 January 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
ISIhor Sobianin
Ihor Sobianin
SPSotiria D. Psoma
Sotiria D. Psoma
ATAntonios Tourlidakis
Antonios Tourlidakis
The human body is a source of multiple types of energy, such as mechanical, thermal and biochemical, which can be scavenged through appropriate technological means. Mechanical vibrations originating from contraction and expansion of the radial artery represent a reliable source of displacement to be picked up and exploited by a harvester. The continuous monitoring of physiological biomarkers is an essential part of the timely and accurate diagnosis of a disease with subsequent medical treatment, and wearable biosensors are increasingly utilized for biomedical data acquisition of important biomarkers. However, they rely on batteries and their replacement introduces a discontinuity in measured signals, which could be critical for the patients and also causes discomfort. In the present work, the research into a novel 3D-printed wearable energy harvesting platform for scavenging energy from arterial pulsations via a piezoelectric material is described. An elastic thermoplastic polyurethane (TPU) film, which forms an air chamber between the skin and the piezoelectric disc electrode, was introduced to provide better adsorption to the skin, prevent damage to the piezoelectric disc and electrically isolate components in the platform from the human body. Computational fluid dynamics in the framework of COMSOL Multiphysics 6.1 software was employed to perform a series of coupled time-varying simulations of the interaction among a number of associated physical phenomena. The mathematical model of the harvester was investigated computationally, and quantification of the output energy and power parameters was used for comparisons. A prototype wearable platform enclosure was designed and manufactured using fused filament fabrication (FFF). The influence of the piezoelectric disc material and its diameter on the electrical output were studied and various geometrical parameters of the enclosure and the TPU film were optimized based on theoretical and empirical data. Physiological data, such as interdependency between the harvester skin fit and voltage output, were obtained.

1 January 2017 in Materials Today: Proceedings
Verified
Journal Article
Closed access
SPSotiria D. Psoma
Sotiria D. Psoma
PTP. Tzanetis
P. Tzanetis
ATA. Tourlidakis
A. Tourlidakis

24 May 2023 in Materials Today: Proceedings
Verified
Journal Article
Open access
ISIhor Sobianin
Ihor Sobianin
SPSotiria D. Psoma
Sotiria D. Psoma
ATAntonios Tourlidakis
Antonios Tourlidakis