Energy harvesters serve as continuous and long-lasting sources of energy that can be integrated into wearable and implantable sensors and biomedical devices. This review paper presents the current progress, the challenges, the advantages, the disadvantages and the future trends of energy harvesters which can harvest energy from various sources from the human body. The most used types of energy are chemical; thermal and biomechanical and each group is represented by several nano-generators. Chemical energy can be harvested with a help of microbial and enzymatic biofuel cells, thermal energy is collected via thermal and pyroelectric nano-generators, biomechanical energy can be scavenged with piezoelectric and triboelectric materials, electromagnetic and electrostatic generators and photovoltaic effect allows scavenging of light energy. Their operating principles, power ratings, features, materials, and designs are presented. There are different ways of extracting the maximum energy and current trends and approaches in nanogenerator designs are discussed. The ever-growing interest in this field is linked to a larger role of wearable electronics in the future. Possible directions of future development are outlined; and practical biomedical applications of energy harvesters for glucose sensors, oximeters and pacemakers are presented. Based on the increasingly accumulated literature, there are continuous promising improvements which are anticipated to lead to portable and implantable devices without the requirement for batteries.
The human body is a source of multiple types of energy, such as mechanical, thermal and biochemical, which can be scavenged through appropriate technological means. Mechanical vibrations originating from contraction and expansion of the radial artery represent a reliable source of displacement to be picked up and exploited by a harvester. The continuous monitoring of physiological biomarkers is an essential part of the timely and accurate diagnosis of a disease with subsequent medical treatment, and wearable biosensors are increasingly utilized for biomedical data acquisition of important biomarkers. However, they rely on batteries and their replacement introduces a discontinuity in measured signals, which could be critical for the patients and also causes discomfort. In the present work, the research into a novel 3D-printed wearable energy harvesting platform for scavenging energy from arterial pulsations via a piezoelectric material is described. An elastic thermoplastic polyurethane (TPU) film, which forms an air chamber between the skin and the piezoelectric disc electrode, was introduced to provide better adsorption to the skin, prevent damage to the piezoelectric disc and electrically isolate components in the platform from the human body. Computational fluid dynamics in the framework of COMSOL Multiphysics 6.1 software was employed to perform a series of coupled time-varying simulations of the interaction among a number of associated physical phenomena. The mathematical model of the harvester was investigated computationally, and quantification of the output energy and power parameters was used for comparisons. A prototype wearable platform enclosure was designed and manufactured using fused filament fabrication (FFF). The influence of the piezoelectric disc material and its diameter on the electrical output were studied and various geometrical parameters of the enclosure and the TPU film were optimized based on theoretical and empirical data. Physiological data, such as interdependency between the harvester skin fit and voltage output, were obtained.
1 January 2019 in Технология и конструирование в электронной аппаратуре
Today LED lamps are used more and more widely in various fields of human activity. The operation of LEDs substantially depends on the thermal dissipation power and temperature. In this regard, one of the mandatory stages in the process of creating such lamps is the analysis of their thermal mode, which is necessary for the development of a heat sink. In order to analyze the thermal mode and design the heat sink for powerful LED lamps, the authors synthesized the structure of the problem solver. The new structure was based on the structure of the basic laplacianFoam solver and the application of the swak4foam library functions, which is a part of the OpenFOAM computational fluid dynamics toolbox. The results of the thermal mode simulation of the LED thermal model (a plate with a rectangular heat source) obtained using a modified solver were compared with those obtained by the proprietary solver of the CAD/CAE SolidWorks system and those obtained by analytical computation. The data adequacy of the modified solver was estimated and its practical application verified. The thermal mode of the Samsung LC009D LED, which is placed on the flat-plate finned heat sink, was analyzed. The Kaufer 5204 glue ability to be used in such design with natural convection cooling of the heat sink was tested. The glue thickness was 0.1 mm and its thermal conductivity was 1,5 W/(m•К). The heat sink’s heat transfer coefficient was 10 W/(м2•К). The paper presents corresponding temperature distributions and shows that the new technique can be used for solving problems that arise when designing LED lamps
1 January 2020 in TECHNICAL SCIENCES AND TECHNOLOGIES
Urgency of the research. The principles of telemedicine need to be put into practice of emergency medical care and family medicine, so there is a need for diagnostic medical equipment with the ability of data transfer and remote consulting with subject matter experts. Target setting. Currently, ECG testing consumes the time to prepare the device for work, needs for the personal computer as the additional equipment and requires highly skilled staff. The development of portable electrocardiographic equipment with built-in means of communication is a task of current importance for biomedical engineering. Actual scientific researches and issues analysis. The current researches in the development of portable cardiograph for primary preclinical diagnostics are focused on the choice of optimal design parameters of device and the incensement of noise immunity of medical equipment. Uninvestigated parts of general matters defining. This article focuses on the design development of the portable electrocardiograph with built-in GSM module for operation in telemedicine systems. The research objective is the design of the portable electrocardiograph for telemedicine that has a convenient interface for device control, is equipped with means of communication with cardiac care centers, has universal ports for information output to external drives and connection of additional devices, is as ergonomic as possible, meets safety, reliability and energy efficiency requirements. The statement of basic materials. The main design requirements to portable electrocardiographic equipment are formulated. The basic functional units of the device are chosen and its electronic block diagram is synthesized. The computer simulation of processes and parameters of the circuitry of the instrumentation amplifier functionality at given operating temperatures proves the validity of proposed circuit design. The constructive implementation of the schematic diagram is designed. The device constructive parameters that meet the requirements of telemedicine most closely are defined. Conclusions. The key features of the designed portable electrocardiograph with GSM module are: the embodiment in folding form-factor, the availability of GSM module, the constant connection of ECG electrodes via integrated ECG cable. The embodiment in folding form-factor optimizes ergonomic characteristics of the device. The replacement of non-integral ECG cable with integrated one reduces the intensity of internal noise and reduces time to prepare the device for work. Builtin GSM module provides affordable communication with specialized medical facilities, thus reducing the duration of the diagnostics and increasing the efficiency of the medical care in non-ambulatory out-hospital an outpatient setting.
Wearable biosensors play a critical role in healthcare monitoring. However, the reliance of biosensors on batteries has serious drawbacks. Although the human body’s energy can be converted into electricity with energy harvesters, the hybridisation of multiple energy harvesters is a prominent way of increasing power output. In this work, a hybrid piezoelectric and reverse electrowetting (REWOD) energy harvester is proposed. Its main working principle is based on the presence of an electrical double layer in the REWOD component and coupling with a piezoelectric nanogenerator via an electret. The proposed energy harvester design was tested numerically and in a series of experiments.
A critical characteristic for continuous monitoring using DNA biosensors is the design of the microfluidics system used for sample manipulation, effective and rapid reaction and an ultra-low detection limit of the analyte. The selection of the appropriate geometrical design and control of microfluidic parameters are highly important for the optimum performance. In the present study, a number of different shapes of microchambers are designed and computationally assessed using a Multiphysics software. Flow parameters such as pressure drop, and shear rates are compared. Three-dimensional printing was used to construct the designs and an experimental investigation is underway for the validation of the computational results.