Michael Pretterklieber

Prof. Dr. Michael Pretterklieber

Medical University of Vienna, Center for Anatomy and Cell Biology, Division of Anatomy, 1090 Vienna, Austria

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 November 2010 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
MCMathieu Charlebois
Mathieu Charlebois
MPMichael Pretterklieber
Michael Pretterklieber
PZPhilippe K. Zysset
Philippe K. Zysset
Osteoporosis-related vertebral body fractures involve large compressive strains of trabecular bone. The small strain mechanical properties of the trabecular bone such as the elastic modulus or ultimate strength can be estimated using the volume fraction and a second order fabric tensor, but it remains unclear if similar estimations may be extended to large strain properties. Accordingly, the aim of this work is to identify the role of volume fraction and especially fabric in the large strain compressive behavior of human trabecular bone from various anatomical locations. Trabecular bone biopsies were extracted from human T12 vertebrae (n=31), distal radii (n=43), femoral head (n=44), and calcanei (n=30), scanned using microcomputed tomography to quantify bone volume fraction (BV/TV) and the fabric tensor (M), and tested either in unconfined or confined compression up to very large strains (∼70%). The mechanical parameters of the resulting stress-strain curves were analyzed using regression models to examine the respective influence of BV/TV and fabric eigenvalues. The compressive stress-strain curves demonstrated linear elasticity, yielding with hardening up to an ultimate stress, softening toward a minimum stress, and a steady rehardening followed by a rapid densification. For the pooled experiments, the average minimum stress was 1.89±1.77 MPa, while the corresponding mean strain was 7.15±1.84%. The minimum stress showed a weaker dependence with fabric as the elastic modulus or ultimate strength. For the confined experiments, the stress at a logarithmic strain of 1.2 was 8.08±7.91 MPa, and the dissipated energy density was 5.67±4.42 MPa. The latter variable was strongly related to the volume fraction (R2=0.83) but the correlation improved only marginally with the inclusion of fabric (R2=0.84). The influence of fabric on the mechanical properties of human trabecular bone decreases with increasing strain, while the role of volume fraction remains important. In particular, the ratio of the minimum versus the maximum stress, i.e., the relative amount of softening, decreases strongly with fabric, while the dissipated energy density is dominated by the volume fraction. The collected results will prove to be useful for modeling the softening and densification of the trabecular bone using the finite element method.

1 January 1994 in Cells Tissues Organs
Verified
Journal Article
Closed access
PDF file
MPMichael Pretterklieber
Michael Pretterklieber
ASA. Schindler
A. Schindler
EKE.B. Krammer
E.B. Krammer
The left ophthalmic artery (OA) of a Caucasian male originated from the transverse portion of the cavernous part of the internal carotid artery (ICA), indicating the persistence of a dorsal OA. It entered the orbit through the most medial part of the superior orbital fissure, close to the medial aspect of the ophthalmic nerve. In the orbital cavity, the OA crossed above the optic nerve to reach the medial wall of the orbit. At the medial end of the upper eyelid it anastomosed with the angular artery and thereafter divided into the dorsal nasal and supratrochlear arteries. Whereas the right OA did not present any irregularities, some additional anatomical variations, above all a bilateral pterygospinosus muscle, were found in this individual. Since except the existence neither the course and branching pattern of a persistent dorsal OA nor its occurrence together with other varieties have been previously reported in man, phylogenetic and ontogenetic aspects of this aberrant vessel are discussed.

6 June 2012 in Anatomy Research International
Verified
Journal Article
Open access
PDF file
GNGregor Nemschak
Gregor Nemschak
MPMichael Pretterklieber
Michael Pretterklieber
Even though the vascular supply of the human patella has been object of numerous studies until now, none of them has described in detail the rich arterial supply provided via the infrapatellar fat pad (of Hoffa). Therefore, we aimed to complete the knowledge about this interesting and clinically relevant topic. Five human patellae taken from voluntary body donators were studied at the Department of Applied Anatomy of the Medical University of Vienna. One was dissected under the operation microscope, a second was made translucent by Sihlers-solution, and three underwent angiography using a 3D X-ray unit. The results revealed that the patella to a considerable amount is supplied by arteries coursing through the surrounding parts of the infrapatellar fat pad. The latter were found to branch off from the medial and lateral superior and inferior genicular arteries. Within the infrapatellar fat pad, these arteries formed a dense network of anastomoses which are all contributing to the viability of the patellar bone. Due to the rich arterial supply reaching the patella via the infrapatellar fat pad, it seems advisable to preserve the fat pad during surgery of the knee in order to reduce the risk of vascular impairment of the patella.

1 November 2019 in Annals of Anatomy - Anatomischer Anzeiger
Verified
Journal Article
Closed access
SUStefanie Urban
Stefanie Urban
BPBettina Pretterklieber
Bettina Pretterklieber
MPMichael Pretterklieber
Michael Pretterklieber

28 October 2021 in Medicina
Verified
Journal Article
Open access
PDF file
MSMartin Siwetz
Martin Siwetz
NTNicol Turnowsky
Nicol Turnowsky
NHNiels Hammer
Niels Hammer
MPMichael Pretterklieber
Michael Pretterklieber
AWAndreas Wree
Andreas Wree
VAVeronica Alexandra Antipova
Veronica Alexandra Antipova
Background and Objectives: Vascular variations appear as morphologically distinct patterns of blood diverging from the most commonly observed vessel patterns. The facial artery is considered to be the main vessel for supplying blood to the anterior part of the face. An anatomical understanding of the facial artery, its course, its topography, and its branches is important in medical and dental practice (especially in neck and face surgery), and is also essential for radiologists to be able to interpret vascular imaging in the face following angiography of the region. A profound knowledge of the arteries in the region will aid in minimizing the risks to the patient. Materials and Methods: In our publication a narrative literature review and a case report are presented. Results: A rare case of a facial artery pattern has been described anatomically for the first time with respect to its course and branching. This variation was found on the left side of a 60-year-old male corpse during anatomical dissection. The anterior branch of the facial artery arched in the direction of the labial angle, and there divided into the inferior and superior labial arteries. At the same time, the posterior branch coursed vertically and superficially to the masseter muscle. It here gave off the premasseteric branch, and continued towards the nose, where it ran below the levator labii superioris and the levator labii superioris alaeque nasi muscles and terminated at the dorsum nasi. Conclusions: Our review of the literature and the case report add to knowledge on the facial artery with respect to its topographical anatomy and its branching and termination patterns, as well as the areas of supply. An exact knowledge of individual facial artery anatomy may play an important role in the planning of flaps or tumor excisions due to the differing vascularization and can also help to prevent artery injuries during aesthetic procedures such as filler and botulinum toxin injections.

2 May 2022 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
DSDenis Schenk
Denis Schenk
MIMichael Indermaur
Michael Indermaur
MSMathieu Simon
Mathieu Simon
BVBenjamin Voumard
Benjamin Voumard
PVPeter Varga
Peter Varga
PZPhilippe Zysset
Philippe Zysset
HR-pQCT based micro finite element (μFE) analyses are considered as "gold standard" for virtual biomechanical analyses of peripheral bone sites such as the distal segment of radius and tibia. An attractive alternative for clinical use is a homogenized finite element method (hFE) based on constitutive models, because of its much shorter evaluation times and modest computational resource requirements. Such hFE models have been experimentally validated for the distal segment of the radius, but neither for the distal segments of the tibia nor for both measurement sites together. Accordingly, the aim of the present study was to refine and experimentally validate an hFE processing pipeline for in vivo prediction of bone strength and stiffness at the distal segments of the radius and the tibia, using only one unified set of material properties. An existing hFE analysis procedure was refined in several aspects: 1) to include a faster evaluation of material orientation based on the mean surface length (MSL) method, 2) to distinguish cortical and trabecular bone compartments with distinct material properties and 3) to directly superimpose material properties in mixed phase elements instead of densities. Based on an existing dataset of the distal segment of fresh-frozen radii (double sections 20.4 mm, n = 21) and a newly established dataset of the distal segment of fresh-frozen tibiae (triple sections, 30.6 mm, n = 25), a single set of material properties was calibrated on the radius dataset and validated on the tibia dataset by comparing hFE stiffness and ultimate load with respective experimental results, obtained by compressing the samples on a servo-hydraulic testing machine at a monotonic and quasi-static displacement rate up to failure. Using the identified set of material properties, the hFE-predicted stiffness and failure load were in excellent agreement with respective experimental results at both measurement sites (radius stiffness R2 = 0.93, slope = 1.00, intercept = 479 N/mm2/radius ultimate load: R2 = 0.97, slope = 1.00, intercept = 679 N; tibia stiffness R2 = 0.96, slope = 1.01, intercept = -1027 N/mm2/tibia ultimate load: R2 = 0.97, slope = 1.04, intercept = 394 N; combined dataset stiffness R2 = 0.95, slope = 1.01, intercept = -230 N/mm2/combined dataset ultimate load: R2 = 0.97, slope = 1.03, intercept = 495 N). In conjunction with unified BV/TV calibration, the established hFE pipeline accurately predicts experimental stiffness and ultimate load of distal multi-sections at the radius and tibia. Processing time for non-linear analysis was substantially reduced compared to previous μFE and hFE methods but could be further minimized by estimating bone strength based on a fast and linear analysis like as is currently done with μ FE.