Objective: The aim of this study was to evaluate the effect of a deep learning based computer-aided diagnosis (DL-CAD) system on radiologists' interpretation accuracy and efficiency in reading biparametric prostate magnetic resonance imaging scans. Materials and Methods: We selected 100 consecutive prostate magnetic resonance imaging cases from a publicly available data set (PROSTATEx Challenge) with and without histopathologically confirmed prostate cancer. Seven board-certified radiologists were tasked to read each case twice in 2 reading blocks (with and without the assistance of a DL-CAD), with a separation between the 2 reading sessions of at least 2 weeks. Reading tasks were to localize and classify lesions according to Prostate Imaging Reporting and Data System (PI-RADS) v2.0 and to assign a radiologist's level of suspicion score (scale from 1–5 in 0.5 increments; 1, benign; 5, malignant). Ground truth was established by consensus readings of 3 experienced radiologists. The detection performance (receiver operating characteristic curves), variability (Fleiss κ), and average reading time without DL-CAD assistance were evaluated. Results: The average accuracy of radiologists in terms of area under the curve in detecting clinically significant cases (PI-RADS ≥4) was 0.84 (95% confidence interval [CI], 0.79–0.89), whereas the same using DL-CAD was 0.88 (95% CI, 0.83–0.94) with an improvement of 4.4% (95% CI, 1.1%–7.7%; P = 0.010). Interreader concordance (in terms of Fleiss κ) increased from 0.22 to 0.36 (P = 0.003). Accuracy of radiologists in detecting cases with PI-RADS ≥3 was improved by 2.9% (P = 0.10). The median reading time in the unaided/aided scenario was reduced by 21% from 103 to 81 seconds (P < 0.001). Conclusions: Using a DL-CAD system increased the diagnostic accuracy in detecting highly suspicious prostate lesions and reduced both the interreader variability and the reading time.
Objectives: The objectives of this study were to assess patient comfort when imaged on a newly introduced 0.55T low-field magnetic resonance (MR) scanner system with a wider bore opening compared to a conventional 1.5T MR scanner system. Materials and Methods: In this prospective study, fifty patients (mean age: 66.2 ± 17.0 years, 22 females, 28 males) underwent subsequent magnetic resonance imaging (MRI) examinations with matched imaging protocols at 0.55T (MAGNETOM FreeMax, Siemens Healthineers; Erlangen, Germany) and 1.5T (MAGNETOM Avanto Fit, Siemens Healthineers; Erlangen, Germany) on the same day. MRI performed between 05/2021 and 07/2021 was included for analysis. The 0.55T MRI system had a bore opening of 80 cm, while the bore diameter of the 1.5T scanner system was 60 cm. Four patient groups were defined by imaged body regions: (1) cranial or cervical spine MRI using a head/neck coil (n = 27), (2) lumbar or thoracic spine MRI using only the in-table spine coils (n = 10), (3) hip MRI using a large flex coil (n = 8) and (4) upper- or lower-extremity MRI using small flex coils (n = 5). Following the MRI examinations, patients evaluated (1) sense of space, (2) noise level, (3) comfort, (4) coil comfort and (5) overall examination impression on a 5-point Likert-scale (range: 1= “much worse” to 5 = “much better”) using a questionnaire. Maximum noise levels of all performed imaging studies were measured in decibels (dB) by a sound level meter placed in the bore center. Results: Sense of space was perceived to be “better” or “much better” by 84% of patients for imaging examinations performed on the 0.55T MRI scanner system (mean score: 4.34 ± 0.75). Additionally, 84% of patients rated noise levels as “better” or “much better” when imaged on the low-field scanner system (mean score: 3.90 ± 0.61). Overall sensation during the imaging examination at 0.55T was rated as “better” or “much better” by 78% of patients (mean score: 3.96 ± 0.70). Quantitative assessment showed significantly reduced maximum noise levels for all 0.55T MRI studies, regardless of body region compared to 1.5T, i.e., brain MRI (83.8 ± 3.6 dB vs. 89.3 ± 5.4 dB; p = 0.04), spine MRI (83.7 ± 3.7 dB vs. 89.4 ± 2.6 dB; p = 0.004) and hip MRI (86.3 ± 5.0 dB vs. 89.1 ± 1.4 dB; p = 0.04). Conclusions: Patients perceived 0.55T new-generation low-field MRI to be more comfortable than conventional 1.5T MRI, given its larger bore opening and reduced noise levels during image acquisition. Therefore, new concepts regarding bore design and noise level reduction of MR scanner systems may help to reduce patient anxiety and improve well-being when undergoing MR imaging.
29 July 2021 in European Heart Journal - Cardiovascular Imaging
To present and validate a fully automated, deep learning (DL)-based branch-wise coronary artery calcium (CAC) scoring algorithm on a multi-centre dataset. We retrospectively included 1171 patients referred for a CAC computed tomography examination. Total CAC scores for each case were manually evaluated by a human reader. Next, each dataset was fully automatically evaluated by the DL-based software solution with output of the total CAC score and sub-scores per coronary artery (CA) branch [right coronary artery (RCA), left main (LM), left anterior descending (LAD), and circumflex (CX)]. Three readers independently manually scored the CAC for all CA branches for 300 cases from a single centre and formed the consensus using a majority vote rule, serving as the reference standard. Established CAC cut-offs for the total Agatston score were used for risk group assignments. The performance of the algorithm was evaluated using metrics for risk class assignment based on total Agatston score, and unweighted Cohen’s Kappa for branch label assignment. The DL-based software solution yielded a class accuracy of 93% (1085/1171) with a sensitivity, specificity, and accuracy of detecting non-zero coronary calcium being 97%, 93%, and 95%. The overall accuracy of the algorithm for branch label classification was 94% (LM: 89%, LAD: 91%, CX: 93%, RCA: 100%) with a Cohen's kappa of k = 0.91. Our results demonstrate that fully automated total and vessel-specific CAC scoring is feasible using a DL-based algorithm. There was a high agreement with the manually assessed total CAC from a multi-centre dataset and the vessel-specific scoring demonstrated consistent and reproducible results.
Background: Opportunistic prostate cancer (PCa) screening is a controversial topic. Magnetic resonance imaging (MRI) has proven to detect prostate cancer with a high sensitivity and specificity, leading to the idea to perform an image-guided prostate cancer (PCa) screening; Methods: We evaluated a prospectively enrolled cohort of 49 healthy men participating in a dedicated image-guided PCa screening trial employing a biparametric MRI (bpMRI) protocol consisting of T2-weighted (T2w) and diffusion weighted imaging (DWI) sequences. Datasets were analyzed both by human readers and by a fully automated artificial intelligence (AI) software using deep learning (DL). Agreement between the algorithm and the reports—serving as the ground truth—was compared on a per-case and per-lesion level using metrics of diagnostic accuracy and k statistics; Results: The DL method yielded an 87% sensitivity (33/38) and 50% specificity (5/10) with a k of 0.42. 12/28 (43%) Prostate Imaging Reporting and Data System (PI-RADS) 3, 16/22 (73%) PI-RADS 4, and 5/5 (100%) PI-RADS 5 lesions were detected compared to the ground truth. Targeted biopsy revealed PCa in six participants, all correctly diagnosed by both the human readers and AI. Conclusions: The results of our study show that in our AI-assisted, image-guided prostate cancer screening the software solution was able to identify highly suspicious lesions and has the potential to effectively guide the targeted-biopsy workflow.