Objectives: The objectives of this study were to assess patient comfort when imaged on a newly introduced 0.55T low-field magnetic resonance (MR) scanner system with a wider bore opening compared to a conventional 1.5T MR scanner system. Materials and Methods: In this prospective study, fifty patients (mean age: 66.2 ± 17.0 years, 22 females, 28 males) underwent subsequent magnetic resonance imaging (MRI) examinations with matched imaging protocols at 0.55T (MAGNETOM FreeMax, Siemens Healthineers; Erlangen, Germany) and 1.5T (MAGNETOM Avanto Fit, Siemens Healthineers; Erlangen, Germany) on the same day. MRI performed between 05/2021 and 07/2021 was included for analysis. The 0.55T MRI system had a bore opening of 80 cm, while the bore diameter of the 1.5T scanner system was 60 cm. Four patient groups were defined by imaged body regions: (1) cranial or cervical spine MRI using a head/neck coil (n = 27), (2) lumbar or thoracic spine MRI using only the in-table spine coils (n = 10), (3) hip MRI using a large flex coil (n = 8) and (4) upper- or lower-extremity MRI using small flex coils (n = 5). Following the MRI examinations, patients evaluated (1) sense of space, (2) noise level, (3) comfort, (4) coil comfort and (5) overall examination impression on a 5-point Likert-scale (range: 1= “much worse” to 5 = “much better”) using a questionnaire. Maximum noise levels of all performed imaging studies were measured in decibels (dB) by a sound level meter placed in the bore center. Results: Sense of space was perceived to be “better” or “much better” by 84% of patients for imaging examinations performed on the 0.55T MRI scanner system (mean score: 4.34 ± 0.75). Additionally, 84% of patients rated noise levels as “better” or “much better” when imaged on the low-field scanner system (mean score: 3.90 ± 0.61). Overall sensation during the imaging examination at 0.55T was rated as “better” or “much better” by 78% of patients (mean score: 3.96 ± 0.70). Quantitative assessment showed significantly reduced maximum noise levels for all 0.55T MRI studies, regardless of body region compared to 1.5T, i.e., brain MRI (83.8 ± 3.6 dB vs. 89.3 ± 5.4 dB; p = 0.04), spine MRI (83.7 ± 3.7 dB vs. 89.4 ± 2.6 dB; p = 0.004) and hip MRI (86.3 ± 5.0 dB vs. 89.1 ± 1.4 dB; p = 0.04). Conclusions: Patients perceived 0.55T new-generation low-field MRI to be more comfortable than conventional 1.5T MRI, given its larger bore opening and reduced noise levels during image acquisition. Therefore, new concepts regarding bore design and noise level reduction of MR scanner systems may help to reduce patient anxiety and improve well-being when undergoing MR imaging.
Objectives: To evaluate whether multiparametric bone MRI (mpBMRI) utilising a combination of DWI signal, ADC and relative fat-fraction (rFF) can identify bone metastases, which provide high diagnostic biopsy yield and next-generation genomic sequencing (NGS) feasibility. Methods: A total of 150 CT-guided bone biopsies performed by interventional radiologists (3/2013 to 2/2021) at our centre were reviewed. In 43 patients, contemporaneous DWI and rFF images, calculated from 2-point T1w Dixon MRI, were available. For each biopsied lesion, a region of interest (ROI) was delineated on ADC and rFF images and the following MRI parameters were recorded: visual classification of DWI signal intensity (SI), mean, median, 10th and 90th centile ADC and rFF values. Non-parametric tests were used to compare values between tumour positive/negative biopsies and feasible/non-feasible NGS, with p-values < 0.05 deemed significant. Results: The mpBMRI combination high DWI signal, mean ADC < 1100 µm2/s and mean rFF < 20% identified tumour-positive biopsies with 82% sensitivity, 80% specificity, a positive predictive value (PPV) of 93% (p = 0.001) and NGS feasibility with 91% sensitivity, 78% specificity and 91% PPV (p < 0.001). The single MRI parameters DWI signal, ADC and rFF failed to distinguish between tumour-positive and tumour-negative biopsies (each p > 0.082). In NGS feasible biopsies, mean and 90th centile rFF were significantly smaller (each p < 0.041). Single ADC parameters did not show significant difference regarding NGS feasibility (each p > 0.292). Conclusions: MpBMRI utilising the combination of DWI signal, ADC and rFF can identify active bone metastases, which provide biopsy tissue with high diagnostic yield and NGS feasibility. Key Points: • Multiparametric bone MRI with diffusion-weighted and relative fat-fraction images helps to identify active bone metastases suitable for CT-guided biopsy.• Target lesions for CT-guided bone biopsies in cancer patients can be chosen with greater confidence.• CT-guided bone biopsy success rates, especially yielding sufficient viable tissue for advanced molecular tissue analyses, can be improved.
Background: Whole body DWI (WB-DWI) enables the identification of lymph nodes for disease evaluation. However, quantitative data of benign lymph nodes across the body are lacking to allow meaningful comparison of diseased states. We evaluated apparent diffusion coefficient (ADC) histogram parameters of all visible lymph nodes in healthy volunteers on WB-DWI and compared differences in nodal ADC values between anatomical regions. Methods: WB-DWI was performed on a 1.5 T MR system in 20 healthy volunteers (7 female, 13 male, mean age 35 years). The b900 images were evaluated by two radiologists and all visible nodes from the neck to groin areas were segmented and individual nodal median ADC recorded. All segmented nodes in a patient were summated to generate the total nodal volume. Descriptors of the global ADC histogram, derived from individual node median ADCs, including mean, median, skewness and kurtosis were obtained for the global volume and each nodal region per patient. ADC values between nodal regions were compared using one-way ANOVA with Bonferroni post hoc tests and a p-value ≤0.05 was deemed statistically significant. Results: One thousand sixty-seven lymph nodes were analyzed. The global mean and median ADC of all lymph nodes were 1.12 ± 0.27 (10− 3 mm2/s) and 1.09 (10− 3 mm2/s). The average median ADC skewness was 0.25 ± 0.02 and average median ADC kurtosis was 0.34 ± 0.04. The ADC values of intrathoracic, portal and retroperitoneal nodes were significantly higher (1.53 × 10− 3, 1.75 × 10− 3 and 1.58 × 10− 3 mm2/s respectively) than in other regions. Intrathoracic, portal and mesenteric nodes were relatively uncommon, accounting for only 3% of the total nodes segmented. Conclusions: The global mean and median ADC of all lymph nodes were 1.12 ± 0.27 (10− 3 mm2/s) and 1.09 (10− 3 mm2/s). Intrathoracic, portal and retroperitoneal nodes display significantly higher ADCs. Normal intrathoracic, portal and mesenteric nodes are infrequently visualized on WB-DWI of healthy individuals. Trial registration: Royal Marsden Hospital committee for clinical research registration number 09/H0801/86, 19.10.2009.
Seven-minute threefold parallel imaging–accelerated deep learning super-resolution 3-T shoulder MRI showed robust diagnostic performance, yielding images of high quality and depicting shoulder abnormalities with good to excellent accuracy.
1 July 2021 in Diagnostic and Interventional Imaging
To compare the measurements of fat fraction (FF) and in-phase vs. opposed-phase ratio between two-dimensional T2-weighted (T2W) spin-echo (SE) Dixon and three-dimensional (3D) T1-weighted (T1W) volume interpolated breath-hold examination (VIBE) Dixon sequences in malignant vertebral lesions and normal vertebral bone marrow. Thirty patients with focal vertebral malignancies (20 men, mean age, 67.3±9.4 [SD] years; age range: 41-84 years) and 30 patients without malignant spinal disease (11 men, mean age, 70.1±12.9 [SD]; age range: 53-93 years) were retrospectively included. Each patient underwent spine MRI at 1.5 Tesla including T2W SE and T1W VIBE 2-point Dixon sequences. Two readers independently performed 3D-volume of interest (VOI) and region of interest (ROI)-based FF and IO-ratio measurements of malignant lesions and normal vertebrae. Student t-test, Pearson correlation (r) test and two-way mixed model intraclass correlation coefficients (ICC) were used to compare measurements. T2W SE and T1W VIBE mean FF and IO-ratio were significantly smaller in malignancy compared to normal marrow, but there were significant differences of paired measurement mean values between T2W SE and T1W VIBE Dixon parameters in malignant lesions T2W SE VOI FF=9%, T2W SE ROI FF=7%, T2W SE IO-ratio=4% vs. T1W VIBE VOI FF=11%, T1W VIBE ROI FF=9%, T1W VIBE IO-ratio=-2%, and in normal vertebrae T2W SE VOI FF=74%, T2W SE ROI FF=77%, T2W SE IO-ratio=51% vs. T1W VIBE VOI FF=67%, T1W VIBE ROI FF=73%, T1W VIBE IO-ratio=58% (each P comparing the paired T2W TSE and T1W VIBE parameter, respectively<0.001). There was excellent positive correlation between T2W SE and T1W VIBE-FF (r≥0.99) and VOI and ROI FF measurements for each sequence (r≥0.99). Inter-reader agreement was excellent for all measurements (ICC≥0.94 for all). Calculation of T2W SE Dixon derived FF is feasible and gave valid results that help discriminate between malignant vertebral lesions and normal vertebral bone marrow.
To compare fat fraction (FF) and apparent diffusion coefficient (ADC) as discriminators distinguishing malignant from acute/subacute osteoporotic vertebral fractures. 1.5 T MRIs of 42 malignant and 27 acute/subacute osteoporotic vertebral fractures (38 patients) were retrospectively reviewed. Two readers independently classified fractures as malignant or osteoporotic based on conventional imaging morphology. Diagnostic reader confidence was rated as confident or not confident. FF was derived from axial T1 gradient-echo 2-point Dixon MRI. ADC maps were calculated from axial b50 and b900 images. Both readers independently performed ROI measurements of mean FF and ADC of the same fractured vertebrae. FF and ADC values, corresponding ROC curves and optimized cut-off value performance were compared. Inter-reader agreement was analysed by calculation of intraclass correlation coefficients (ICCs). A p-value < 0.05 was deemed significant. Mean FF and ADC were significantly lower in malignant (9.5 % and 1.05 × 10-3 mm²/s) compared to osteoporotic fractures (32 % and 1.34 × 10-3 mm²/s, all p < 0.001). The optimal cut-off FF was 11.5 %, detecting malignant fractures with 86 %/89 % sensitivity/specificity. The optimal ADC cut-off of 1.04 × 10-3 mm/s² yielded 62 %/96 % sensitivity/specificity. FF AUC (0.93) was significantly larger than ADC AUC (0.82, p = 0.03). In the subgroup of nine cases reported with low expert reader confidence, the optimized cut-off specificities of FF (83 %) and ADC (83 %) exceeded reader specificity (50 %). There was excellent inter-reader agreement for mean FF (ICC = 0.99) and good agreement for mean ADC (ICC = 0.86) measurements. FF and ADC can improve reader specificity to distinguish between malignant and acute or subacute osteoporotic vertebral fractures. As single discriminator, FF was superior to ADC.