‘Smart’ structural health monitoring of composite materials with optical fiber sensors is becoming more and more important, especially in the aviation industry. This paper presents an overview of hybrid fiber-optic sensing systems based on scattering techniques, fiber Bragg gratings, interferometric techniques, and polarimetric methods in structural health monitoring. The main purpose of this manuscript is to analyze the possibilities of using hybrid sensors based on fiber optics to monitor composite structures, with a particular emphasis on aircraft structures. Since it is difficult to indicate the most comprehensive approach due to different parameters of the described sensors, the review contains a detailed description of available solutions. We hope that this work will allow for a better and faster selection of the right solution for the problem at hand.
Sophisticated techniques employed in radiotherapy for irradiation of tumours require comprehensive dosimetry allowing for precise, high resolution measurements of radiation dose distribution in three dimensions and verification of treatment planning systems. Polymer gel dosimetry has been shown to be a unique technique for three-dimensional high resolution measurements of absorbed radiation dose distributions. If exposed to ionizing radiation, radical polymerisation and crosslinking of monomeric components take place in a 3D polymer gel dosimeter, leading to the formation of large polymeric structures that scatter visible light. This feature allows for optical observation of the effects of the absorbed dose and its distribution. Presently, magnetic resonance imaging is employed the most often for analysis of 3D polymer gel dosimeters. However, much attention is also being given to the development of optical computed tomography since this technique is hoped to serve as a substitute for expensive and not easily available magnetic resonance imaging. The optical scanner presented in this work consists of a laser diode, a scanning system and a signal detector. A 3D polymer gel dosimeter is measured in an immersion liquid in order to reduce deflection of the light from the dosimeter phantom. The very first results were obtained with the newly constructed scanner for PABIG 3D polymer gel dosimeter, which was inhomogeneously irradiated with Ir brachytherapy source. The results have been contrasted with those for magnetic resonance imaging and are presented in this work together with the description of the optical scanner. Currently, optimization of the optical scanner is performed.
Compliant mechanisms have gained an increasing interest in recent years, especially in relation to the possibility of using 3D printers for their production. These mechanisms typically find applications in precise positioning systems of building robotic devices or in sensing where they can be used to characterize displacement. Three-dimensional printing with PLA materials allows fiber optic-based sensors to be incorporated into the structures of properly designed compliant mechanisms. Therefore, in this paper, an innovative technology is described, of a Fiber Bragg Grating (FBG) sensor embedded in a measuring head which was then inserted into a specially designed mechanical transmission element. The shape of this element is based on clippers that allow to freely modify the amplification of displacement amplitude so that the FBG sensor always works in the most optimal regime without any need to modify its external dimensions. Flexural sensitivity of the replaceable measuring head equal to 1.26 (mε/mm) can be adapted to the needs of the flexure design.
Polymer–matrix composites degrade under the influence of UV radiation in the range of the 290–400 nm band. The degradation of polymer–matrix composites exposed to UV radiation is characterized by extensive aging of the epoxy matrix, resulting in deterioration of their mechanical properties. Glass fibers/epoxy resin composites were made by an out-of-autoclave method whereas a fiber optic sensor was placed between different layers of laminates. In our work, we used a fiber Bragg grating sensor covered with graphene oxide and embedded in a polymer matrix composite to monitor UV radiation intensity. Measurements of UV radiation may allow monitoring the aging process of individual components of the polymer composite. In order to estimate the number of microcracks of epoxy resin, microstructure observations were carried out using a scanning electron microscope.
The unique components of PDMS-based microfluidic systems are those combined with liquid crystalline materials. Their functionality, especially when it comes to optical applications, highly depends on the LC molecular arrangement. This work summarizes experimental investigations on the orientation of molecules within LC:PDMS structures according to the manufacturing technologies. The availability of high-quality molds to pattern PDMS is a significant barrier to the creation of advanced microfluidic systems. The possibility of using inexpensive molds in the rapid and reproducible fabrication process has been particularly examined as an alternative to photolithography. Different geometries, including an innovative approach for the electrical control of the molecular arrangement within PDMS microchannels, are presented. These studies are critical for novel optofluidic systems, introducing further research on LC:PDMS waveguiding structures.