Dong Han

Ms. Dong Han

UNIVERSITY OF CONNECTICUT, STORRS, CT 06269
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 October 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Syed Khairul BasharSyed Khairul Bashar
Syed Khairul Bashar
DHDong Han
Dong Han
SHShirin Hajeb-M
Shirin Hajeb-M
EDEric Ding
Eric Ding
CWCody Whitcomb
Cody Whitcomb
KCKi Chon
Ki Chon
Detection of atrial fibrillation (AF) from a wrist watch photoplethysmogram (PPG) signal is important because the wrist watch form factor enables long term continuous monitoring of arrhythmia in an easy and non-invasive manner. We have developed a novel method not only to detect AF from a smart wrist watch PPG signal, but also to determine whether the recorded PPG signal is corrupted by motion artifacts or not. We detect motion and noise artifacts based on the accelerometer signal and variable frequency complex demodulation based time-frequency analysis of the PPG signal. After that, we use the root mean square of successive differences and sample entropy, calculated from the beat-to-beat intervals of the PPG signal, to distinguish AF from normal rhythm. We then use a premature atrial contraction detection algorithm to have more accurate AF identification and to reduce false alarms. Two separate datasets have been used in this study to test the efficacy of the proposed method, which shows a combined sensitivity, specificity and accuracy of 98.18%, 97.43% and 97.54% across the datasets.

5 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
DHDong Han
Dong Han
Syed Khairul BasharSyed Khairul Bashar
Syed Khairul Bashar
FMFahimeh Mohagheghian
Fahimeh Mohagheghian
EDEric Ding
Eric Ding
CWCody Whitcomb
Cody Whitcomb
KCKi Chon
Ki Chon
We developed an algorithm to detect premature atrial contraction (PAC) and premature ventricular contraction (PVC) using photoplethysmographic (PPG) data acquired from a smartwatch. Our PAC/PVC detection algorithm is composed of a sequence of algorithms that are combined to discriminate various arrhythmias. A novel vector resemblance method is used to enhance the PAC/PVC detection results of the Poincaré plot method. The new PAC/PVC detection algorithm with our automated motion and noise artifact detection approach yielded a sensitivity of 86% for atrial fibrillation (AF) subjects while the overall sensitivity was 67% when normal sinus rhythm (NSR) subjects were also included. The specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy values for the combined data consisting of both NSR and AF subjects were 97%, 81%, 94% and 92%, respectively, for PAC/PVC detection combined with our automated motion and noise artifact detection approach. Moreover, when AF detection was compared with and without PAC/PVC, the sensitivity and specificity increased from 94.55% to 98.18% and from 95.75% to 97.90%, respectively. For additional independent testing data, we used two datasets: a smartwatch PPG dataset that was collected in our ongoing clinical study, and a pulse oximetry PPG dataset from the Medical Information Mart for Intensive Care III database. The PAC/PVC classification results of the independent testing on these two other datasets are all above 92% for sensitivity, specificity, PPV, NPV, and accuracy. The proposed combined approach to detect PAC and PVC can ultimately lead to better accuracy in AF detection. This is one of the first studies involving detection of PAC and PVC using PPG recordings from a smartwatch. The proposed method can potentially be of clinical importance as this enhanced capability can lead to fewer false positive detections of AF, especially for those NSR subjects with frequent episodes of PAC/PVC.

20 January 2021 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Syed Khairul BasharSyed Khairul Bashar
Syed Khairul Bashar
DHDong Han
Dong Han
FZFearass Zieneddin
Fearass Zieneddin
EDEric Ding
Eric Ding
TFTimothy P. Fitzgibbons
Timothy P. Fitzgibbons
KCKi Chon
Ki Chon
Objective: Detection of Atrial fibrillation (AF) from premature atrial contraction (PAC) and premature ventricular contraction (PVC) is difficult as frequent occurrences of these ectopic beats can mimic the typical irregular patterns of AF. In this paper, we present a novel density Poincaré plot-based machine learning method to detect AF from PAC/PVCs using electrocardiogram (ECG) recordings. Methods: First, we propose the generation of this new density Poincaré plot which is derived from the difference of the heart rate (DHR) and provides the overlapping phase-space trajectory information of the DHR. Next, from this density Poincaré plot, several image processing domain-based approaches including statistical central moments, template correlation, Zernike moment, discrete wavelet transform and Hough transform features are used to extract suitable features. Subsequently, the infinite latent feature selection algorithm is implemented to rank the features. Finally, classification of AF vs. PAC/PVC is performed using K-Nearest Neighbor, Support vector machine (SVM) and Random Forest (RF) classifiers. Our method is developed and validated using a subset of Medical Information Mart for Intensive Care (MIMIC) III database containing 10 AF and 10 PAC/PVC subjects. Results- During the segment-wise 10-fold cross-validation, SVM achieved the best performance with 98.99% sensitivity, 95.18% specificity and 97.45% accuracy with the extracted features. In subject-wise scenario, RF achieved the highest accuracy of 91.93%. Moreover, we further validated the proposed method using two other databases: wearable armband ECG data and the Physionet AFPDB. 100% PAC detection accuracy was obtained for both databases without any further training. Conclusion: Our proposed density Poincaré plot-based method showed superior performance when compared with four existing algorithms; thus showing the efficacy of the extracted image domain-based features. Significance: From intensive care unit's ECG to wearable armband ECGs, the proposed method is shown to discriminate PAC/PVCs from AF with high accuracy.

29 January 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
DHDong Han
Dong Han
Syed Khairul BasharSyed Khairul Bashar
Syed Khairul Bashar
JLJesus Lazaro
Jesus Lazaro
FMFahimeh Mohagheghian
Fahimeh Mohagheghian
APAndrew Peitzsch
Andrew Peitzsch
KCKi Chon
Ki Chon
Objective: We have developed a peak detection algorithm for accurate determination of heart rate, using photoplethysmographic (PPG) signals from a smartwatch, even in the presence of various cardiac rhythms, including normal sinus rhythm (NSR), premature atrial contraction (PAC), premature ventricle contraction (PVC), and atrial fibrillation (AF). Given the clinical need for accurate heart rate estimation in patients with AF, we developed a novel approach that reduces heart rate estimation errors when compared to peak detection algorithms designed for NSR. Methods: Our peak detection method is composed of a sequential series of algorithms that are combined to discriminate the various arrhythmias described above. Moreover, a novel Poincaré plot scheme is used to discriminate between basal heart rate AF and rapid ventricular response (RVR) AF, and to differentiate PAC/PVC from NSR and AF. Training of the algorithm was performed only with Samsung Simband smartwatch data, whereas independent testing data which had more samples than did the training data were obtained from Samsung’s Gear S3 and Galaxy Watch 3. Results: The new PPG peak detection algorithm provides significantly lower average heart rate and interbeat interval beat-to-beat estimation errors—30% and 66% lower—and mean heart rate and mean interbeat interval estimation errors—60% and 77% lower—when compared to the best of the seven other traditional peak detection algorithms that are known to be accurate for NSR. Our new PPG peak detection algorithm was the overall best performers for other arrhythmias. Conclusion: The proposed method for PPG peak detection automatically detects and discriminates between various arrhythmias among different waveforms of PPG data, delivers significantly lower heart rate estimation errors for participants with AF, and reduces the number of false negative peaks. Significance: By enabling accurate determination of heart rate despite the presence of AF with rapid ventricular response or PAC/PVCs, we enable clinicians to make more accurate recommendations for heart rate control from PPG data.

11 March 2022 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
FMFahimeh Mohagheghian
Fahimeh Mohagheghian
DHDong Han
Dong Han
APAndrew Peitzsch
Andrew Peitzsch
NNNishat Nishita
Nishat Nishita
EDEric Ding
Eric Ding
KCKi Chon
Ki Chon
Objective: With the increasing use of wearable healthcare devices for remote patient monitoring, reliable signal quality assessment (SQA) is required to ensure the high accuracy of interpretation and diagnosis on the recorded data from patients. Photoplethysmographic (PPG) signals non-invasively measured by wearable devices are extensively used to provide information about the cardiovascular system and its associated diseases. In this study, we propose an approach to optimize the quality assessment of the PPG signals. Methods: We used an ensemble-based feature selection scheme to enhance the prediction performance of the classification model to assess the quality of the PPG signals. Our approach for feature and subset size selection yielded the best-suited feature subset, which was optimized to differentiate between the clean and artifact corrupted PPG segments. Conclusion: A high discriminatory power was achieved between two classes on the test data by the proposed feature selection approach, which led to strong performance on all dependent and independent test datasets. We achieved accuracy, sensitivity, and specificity rates of higher than 0.93, 0.89, and 0.97, respectively, for dependent test datasets, independent of heartbeat type, i.e., atrial fibrillation (AF) or non-AF data including normal sinus rhythm (NSR), premature atrial contraction (PAC), and premature ventricular contraction (PVC). For independent test datasets, accuracy, sensitivity, and specificity rates were greater than 0.93, 0.89, and 0.97, respectively, on PPG data recorded from AF and non-AF subjects. These results were found to be more accurate than those of all of the contemporary methods cited in this work. Significance: As the results illustrate, the advantage of our proposed scheme is its robustness against dynamic variations in the PPG signal during long-term 14-day recordings accompanied with different types of physical activities and a diverse range of fluctuations and waveforms caused by different individual hemodynamic characteristics, and various types of recording devices. This robustness instills confidence in the application of the algorithm to various kinds of wearable devices as a reliable PPG signal quality assessment approach.

15 May 2019 in JMIR Cardio
Verified
Journal Article
Open access
EDEric Y Ding
Eric Y Ding
DHDong Han
Dong Han
CWCody Whitcomb
Cody Whitcomb
Syed Khairul BasharSyed Khairul Bashar
Syed Khairul Bashar
OAOluwaseun Adaramola
Oluwaseun Adaramola
DMDavid D McManus
David D McManus
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Atrial fibrillation (AF) is often paroxysmal and minimally symptomatic, hindering its diagnosis. Smartwatches may enhance AF care by facilitating long-term, non-invasive monitoring. Objective: We aimed to examine the accuracy and usability of arrhythmia discrimination using a smartwatch. Methods: Forty adults presenting to a cardiology clinic wore a smartwatch and performed scripted movements to simulate activities of daily living (ADLs). Clinical and sociodemographic characteristics of participants were abstracted from medical records. Participants completed a questionnaire assessing usability and different domains of their experience with the device. Pulse recordings were analyzed blindly using a real-time realizable algorithm and compared to gold-standard Holter monitoring. Results: Average age of participants was 71  8 years, most had AF risk factors, and 9 (23%) were in AF. About half of participants owned smartphones but none owned smartwatches. Participants wore the smartwatch for 42  14 minutes while generating motion noise to simulate ADLs. The algorithm determined 53 of 314 30-second noise-free pulse segments as consistent with AF. Compared to the gold-standard, the algorithm demonstrated excellent sensitivity (98.2%), specificity (98.1%), and accuracy (98.1%) for identifying irregular pulse. Two-thirds of participants considered the smartwatch highly usable. Younger age and prior cardioversion were associated with greater overall comfort and comfort with data privacy with using a smartwatch for rhythm monitoring, respectively. Conclusions: A real-time realizable algorithm analyzing smartwatch pulse recordings demonstrated high accuracy for identifying pulse irregularities among older participants simulating ADLs. Despite advanced age, lack of smartwatch familiarity, and high burden of comorbidities, participants found the smartwatch to be highly acceptable.