We developed an algorithm to detect premature atrial contraction (PAC) and premature ventricular contraction (PVC) using photoplethysmographic (PPG) data acquired from a smartwatch. Our PAC/PVC detection algorithm is composed of a sequence of algorithms that are combined to discriminate various arrhythmias. A novel vector resemblance method is used to enhance the PAC/PVC detection results of the Poincaré plot method. The new PAC/PVC detection algorithm with our automated motion and noise artifact detection approach yielded a sensitivity of 86% for atrial fibrillation (AF) subjects while the overall sensitivity was 67% when normal sinus rhythm (NSR) subjects were also included. The specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy values for the combined data consisting of both NSR and AF subjects were 97%, 81%, 94% and 92%, respectively, for PAC/PVC detection combined with our automated motion and noise artifact detection approach. Moreover, when AF detection was compared with and without PAC/PVC, the sensitivity and specificity increased from 94.55% to 98.18% and from 95.75% to 97.90%, respectively. For additional independent testing data, we used two datasets: a smartwatch PPG dataset that was collected in our ongoing clinical study, and a pulse oximetry PPG dataset from the Medical Information Mart for Intensive Care III database. The PAC/PVC classification results of the independent testing on these two other datasets are all above 92% for sensitivity, specificity, PPV, NPV, and accuracy. The proposed combined approach to detect PAC and PVC can ultimately lead to better accuracy in AF detection. This is one of the first studies involving detection of PAC and PVC using PPG recordings from a smartwatch. The proposed method can potentially be of clinical importance as this enhanced capability can lead to fewer false positive detections of AF, especially for those NSR subjects with frequent episodes of PAC/PVC.

29 January 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
DHDong Han
Dong Han
Syed Khairul BasharSyed Khairul Bashar
Syed Khairul Bashar
JLJesus Lazaro
Jesus Lazaro
FMFahimeh Mohagheghian
Fahimeh Mohagheghian
APAndrew Peitzsch
Andrew Peitzsch
KCKi Chon
Ki Chon
Objective: We have developed a peak detection algorithm for accurate determination of heart rate, using photoplethysmographic (PPG) signals from a smartwatch, even in the presence of various cardiac rhythms, including normal sinus rhythm (NSR), premature atrial contraction (PAC), premature ventricle contraction (PVC), and atrial fibrillation (AF). Given the clinical need for accurate heart rate estimation in patients with AF, we developed a novel approach that reduces heart rate estimation errors when compared to peak detection algorithms designed for NSR. Methods: Our peak detection method is composed of a sequential series of algorithms that are combined to discriminate the various arrhythmias described above. Moreover, a novel Poincaré plot scheme is used to discriminate between basal heart rate AF and rapid ventricular response (RVR) AF, and to differentiate PAC/PVC from NSR and AF. Training of the algorithm was performed only with Samsung Simband smartwatch data, whereas independent testing data which had more samples than did the training data were obtained from Samsung’s Gear S3 and Galaxy Watch 3. Results: The new PPG peak detection algorithm provides significantly lower average heart rate and interbeat interval beat-to-beat estimation errors—30% and 66% lower—and mean heart rate and mean interbeat interval estimation errors—60% and 77% lower—when compared to the best of the seven other traditional peak detection algorithms that are known to be accurate for NSR. Our new PPG peak detection algorithm was the overall best performers for other arrhythmias. Conclusion: The proposed method for PPG peak detection automatically detects and discriminates between various arrhythmias among different waveforms of PPG data, delivers significantly lower heart rate estimation errors for participants with AF, and reduces the number of false negative peaks. Significance: By enabling accurate determination of heart rate despite the presence of AF with rapid ventricular response or PAC/PVCs, we enable clinicians to make more accurate recommendations for heart rate control from PPG data.

11 March 2022 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
FMFahimeh Mohagheghian
Fahimeh Mohagheghian
DHDong Han
Dong Han
APAndrew Peitzsch
Andrew Peitzsch
NNNishat Nishita
Nishat Nishita
EDEric Ding
Eric Ding
KCKi Chon
Ki Chon
Objective: With the increasing use of wearable healthcare devices for remote patient monitoring, reliable signal quality assessment (SQA) is required to ensure the high accuracy of interpretation and diagnosis on the recorded data from patients. Photoplethysmographic (PPG) signals non-invasively measured by wearable devices are extensively used to provide information about the cardiovascular system and its associated diseases. In this study, we propose an approach to optimize the quality assessment of the PPG signals. Methods: We used an ensemble-based feature selection scheme to enhance the prediction performance of the classification model to assess the quality of the PPG signals. Our approach for feature and subset size selection yielded the best-suited feature subset, which was optimized to differentiate between the clean and artifact corrupted PPG segments. Conclusion: A high discriminatory power was achieved between two classes on the test data by the proposed feature selection approach, which led to strong performance on all dependent and independent test datasets. We achieved accuracy, sensitivity, and specificity rates of higher than 0.93, 0.89, and 0.97, respectively, for dependent test datasets, independent of heartbeat type, i.e., atrial fibrillation (AF) or non-AF data including normal sinus rhythm (NSR), premature atrial contraction (PAC), and premature ventricular contraction (PVC). For independent test datasets, accuracy, sensitivity, and specificity rates were greater than 0.93, 0.89, and 0.97, respectively, on PPG data recorded from AF and non-AF subjects. These results were found to be more accurate than those of all of the contemporary methods cited in this work. Significance: As the results illustrate, the advantage of our proposed scheme is its robustness against dynamic variations in the PPG signal during long-term 14-day recordings accompanied with different types of physical activities and a diverse range of fluctuations and waveforms caused by different individual hemodynamic characteristics, and various types of recording devices. This robustness instills confidence in the application of the algorithm to various kinds of wearable devices as a reliable PPG signal quality assessment approach.

28 November 2023 in JMIR Cardio
Verified
Journal Article
Open access
EDEric Y Ding
Eric Y Ding
KTKhanh-Van Tran
Khanh-Van Tran
DLDarleen Lessard
Darleen Lessard
ZWZiyue Wang
Ziyue Wang
DHDong Han
Dong Han
DMDavid D McManus
David D McManus
Background: Atrial fibrillation (AF) is a common cause of stroke, and timely diagnosis is critical for secondary prevention. Little is known about smartwatches for AF detection among stroke survivors. We aimed to examine accuracy, usability, and adherence to a smartwatch-based AF monitoring system designed by older stroke survivors and their caregivers. Objective: This study aims to examine the feasibility of smartwatches for AF detection in older stroke survivors. Methods: Pulsewatch is a randomized controlled trial (RCT) in which stroke survivors received either a smartwatch-smartphone dyad for AF detection (Pulsewatch system) plus an electrocardiogram patch or the patch alone for 14 days to assess the accuracy and usability of the system (phase 1). Participants were subsequently rerandomized to potentially 30 additional days of system use to examine adherence to watch wear (phase 2). Participants were aged 50 years or older, had survived an ischemic stroke, and had no major contraindications to oral anticoagulants. The accuracy for AF detection was determined by comparing it to cardiologist-overread electrocardiogram patch, and the usability was assessed with the System Usability Scale (SUS). Adherence was operationalized as daily watch wear time over the 30-day monitoring period. Results: A total of 120 participants were enrolled (mean age 65 years; 50/120, 41% female; 106/120, 88% White). The Pulsewatch system demonstrated 92.9% (95% CI 85.3%-97.4%) accuracy for AF detection. Mean usability score was 65 out of 100, and on average, participants wore the watch for 21.2 (SD 8.3) of the 30 days. Conclusions: Our findings demonstrate that a smartwatch system designed by and for stroke survivors is a viable option for long-term arrhythmia detection among older adults at risk for AF, though it may benefit from strategies to enhance adherence to watch wear. Trial Registration: ClinicalTrials.gov NCT03761394; https://clinicaltrials.gov/study/NCT03761394 International Registered Report Identifier (IRRID): RR2-10.1016/j.cvdhj.2021.07.002

1 January 2023 in Cardiology and Cardiovascular Medicine
Verified
Journal Article
Open access
PDF file
KTKhanh-Van Tran
Khanh-Van Tran
AFAndreas Filippaios
Andreas Filippaios
KNKamran Noorishirazi
Kamran Noorishirazi
EDEric Ding
Eric Ding
DHDong Han
Dong Han
DMDavid D McManus
David D McManus
Wrist-based wearables have been FDA approved for AF detection. However, the health behavior impact of false AF alerts from wearables on older patients at high risk for AF are not known. In this work, we analyzed data from the Pulsewatch (NCT03761394) study, which randomized patients (≥50 years) with history of stroke or transient ischemic attack to wear a patch monitor and a smartwatch linked to a smartphone running the Pulsewatch application vs to only the cardiac patch monitor over 14 days. At baseline and 14 days, participants completed validated instruments to assess for anxiety, patient activation, perceived mental and physical health, chronic symptom management self-efficacy, and medicine adherence. We employed linear regression to examine associations between false AF alerts with change in patient-reported outcomes. Receipt of false AF alerts was related to a dose-dependent decline in self-perceived physical health and levels of disease self-management. We developed a novel convolutional denoising autoencoder (CDA) to remove motion and noise artifacts in photoplethysmography (PPG) segments to optimize AF detection, which substantially reduced the number of false alerts. A promising approach to avoid negative impact of false alerts is to employ artificial intelligence driven algorithms to improve accuracy.

17 September 2023 in Expert Systems with Applications
Verified
Journal Article
Closed access
FMFahimeh Mohagheghian
Fahimeh Mohagheghian
DHDong Han
Dong Han
OGOm Ghetia
Om Ghetia
DCDarren Chen
Darren Chen
APAndrew Peitzsch
Andrew Peitzsch
KCKi Chon
Ki Chon