A concentric annular heat pipe heat sink (AHPHS) was proposed and fabricated to investigate its thermal behavior. The present AHPHS consists of two concentric pipes of different diameters, which create vacuumed annular vapor space. The main advantage of the AHPHS as a heat sink is that it can largely increase the heat transfer area for cooling compared to conventional heat pipes. In the current AHPHS, condensation takes place along the whole annular space from the certain heating area as the evaporator section. Therefore, the whole inner space of the AHPHS except the heating area can be considered the condenser. In the present study, AHPHSs of different diameters were fabricated and studied experimentally. Basic studies were carried out with a 50 mm-long stainless steel AHPHS with diameter ratios of 1.1 and 1.3 and the same inner tube diameter of 76 mm. Several experimental parameters such as volume fractions of 10–70%, different air flow velocity, flow configurations, and 10–50 W heat inputs were investigated to find their effects on the thermal performance of an AHPHS. Experimental results show that a 10% filling ratio was found to be the optimum charged amount in terms of temperature profile with a low heater surface temperature and water as the working fluid. For the methanol, a 40% filling ratio shows better temperature behavior. Internal working behavior shows not only circular motion but also 3-D flow characteristics moving in axial and circular directions simultaneously.
The current research work describes the flow and thermal analysis inside the circular flow region of an annular heat pipe with a working fluid, using computational fluid dynamics (CFD) simulation. A two-phase flow involving simultaneous evaporation and condensation phenomena in a concentric annular heat pipe (CAHP) is modeled. To simulate the interaction between these phases, the volume of fluid (VOF) technique is used. The temperature profile predicted using computational fluid dynamics (CFD) in the CAHP was compared with previously obtained experimental results. Two-dimensional and three-dimensional simulations were carried out, in order to verify the usefulness of 3D modeling. Our goal was to compute the flow characteristics, temperature distribution, and velocity field inside the CAHP. Depending on the shape of the annular heat pipe, the thermal performance can be improved through the optimal design of components, such as the inner width of the annular heat pipe, the location of the condensation part, and the amount of working fluid. To evaluate the thermal performance of a CAHP, a numerical simulation of a 50 mm long stainless steel CAHP (1.1 and 1.3 in diameter ratio and fixed inner tube diameter (78 mm)) was done, which was identical to the experimental system. In the simulated analysis results, similar results to the experiment were obtained, and it was confirmed that the heat dissipation was higher than that of the existing conventional heat pipe, where the heat transfer performance was improved when the asymmetric area was cooled. Moreover, the simulation results were validated using the experimental results. The 3-D simulation shows good agreement with the experimental results to a reasonable degree.
A theory-based prediction method was used to estimate the friction factor and heat transfer rate in the turbulent flow of a helically coiled tube. The secondary flow produced by a centrifugal force improves heat and mass transfer; therefore, spiral coil pipes are widely used in a variety of industrial applications. The law of the wall and the Reynolds analogy, which states that momentum transfer in a turbulent flow is equivalent to heat transfer, were used in this theoretical method. The logarithmic law was used to characterize the velocity profile in the turbulence-dominated region, and the local wall shear stress variation throughout the circumference of the helical tube wall was considered. The friction factor and heat transfer in the turbulent flow of the helically coiled tube were accurately predicted by the model. Using the Reynolds analogy, the local Nusselt number in the circumferential direction of the helical tube wall was determined. The effect of decreasing local heat transfer within the tube while increasing heat transfer outside the tube was quantified. The analogy between the momentum flux and the heat flux in the turbulent flow of the straight tube was also proven to be applicable to the spiral tube.