Federico Morosato

Dr. Federico Morosato

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 May 2023 in Science
Verified
Journal Article
Closed access
FIFrancesco Iberite
Francesco Iberite
JMJonathan Muheim
Jonathan Muheim
OAOutman Akouissi
Outman Akouissi
SGSimon Gallo
Simon Gallo
GRGiulio Rognini
Giulio Rognini
SSSolaiman Shokur
Solaiman Shokur
The use of hands for gathering rich sensory information is essential for proper interaction with the environment; therefore, the restoration of sensation is critical for reestablishing the sense of embodiment in hand amputees. Here, we show that a noninvasive wearable device can be used to provide thermal sensations on amputees’ phantom hands. The device delivers thermal stimuli to specific regions of skin on their residual limb. These sensations were phenomenologically similar to those on the intact limbs and were stable over time. Using the device, the subjects could successfully exploit the thermal phantom hand maps to detect and discriminate different thermal stimuli. The use of a wearable device that provides thermal sensation can increase the sense of embodiment and improve life quality in hand amputees.

19 December 2017 in Journal of Orthopaedic Research
Verified
Journal Article
Closed access
PDF file
FMFederico Morosato
Federico Morosato
FTFrancesco Traina
Francesco Traina
LCLuca Cristofolini
Luca Cristofolini

24 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
ACAndrea Giovanni Cutti
Andrea Giovanni Cutti
FMFederico Morosato
Federico Morosato
CGCosimo Gentile
Cosimo Gentile
FGFrancesca Gariboldi
Francesca Gariboldi
GHGiovanni Hamoui
Giovanni Hamoui
EGEmanuele Gruppioni
Emanuele Gruppioni
The design and fitting of prosthetic sockets can significantly affect the acceptance of an artificial limb by persons with lower limb amputations. Clinical fitting is typically an iterative process, which requires patients’ feedback and professional assessment. When feedback is unreliable due to the patient’s physical or psychological conditions, quantitative measures can support decision-making. Specifically, monitoring the skin temperature of the residual limb can provide valuable information regarding unwanted mechanical stresses and reduced vascularization, which can lead to inflammation, skin sores and ulcerations. Multiple 2D images to examine a real-life 3D limb can be cumbersome and might only offer a partial assessment of critical areas. To overcome these issues, we developed a workflow for integrating thermographic information on the 3D scan of a residual limb, with intrinsic reconstruction quality measures. Specifically, workflow allows us to calculate a 3D thermal map of the skin of the stump at rest and after walking, and summarize this information with a single 3D differential map. The workflow was tested on a person with transtibial amputation, with a reconstruction accuracy lower than 3 mm, which is adequate for socket adaptation. We expect the workflow to improve socket acceptance and patients’ quality of life.

27 September 2020 in Materials
Verified
Journal Article
Open access
PDF file
FMFederico Morosato
Federico Morosato
Francesco TrainaFrancesco Traina
Francesco Traina
RSRonja A. Schierjott
Ronja A. Schierjott
GHGeorg Hettich
Georg Hettich
TGThomas M. Grupp
Thomas M. Grupp
LCLuca Cristofolini
Luca Cristofolini
Hip implant failure is mainly due to aseptic loosening of the cotyle and is typically accompanied by defects in the acetabular region. Revision surgery aims to repair such defects before implantation by means of reconstruction materials, whose morselized bone graft represents the gold standard. Due to the limited availability of bone tissue, synthetic substitutes are also used. The aim of this study was to evaluate if a synthetic fully resorbable tri-calcium phosphate-based substitute can provide adequate mechanical stability when employed to restore severe, contained defects, in comparison with morselized bone graft. Five cadaveric pelvises were adopted, one side was reconstructed with morselized bone graft and the other with the synthetic substitute, consisting of dense calcium phosphate granules within a collagen matrix. During the biomechanical test, cyclic load packages of increasing magnitude were applied to each specimen until failure. Bone/implant motions were measured through Digital Image Correlation and were expressed in terms of permanent and inducible translations and rotations. The reconstruction types exhibited a similar behavior, consisting of an initial settling trend followed by failure as bone fracture (i.e., no failure of the reconstruction material). When 2.2 Body Weight was applied, the permanent translations were not significantly different between the two reconstructions (p = 0.06–1.0) and were below 1.0 mm. Similarly, the inducible translations did not differ significantly (p = 0.06–1.0) and were below 0.160 mm. Rotations presented the same order of magnitude but were qualitatively different. Overall, the synthetic substitute provided adequate mechanical stability in comparison with morselized bone graft, thus representing a reliable alternative to treat severe, contained acetabular defects.

5 February 2023 in Prosthesis
Verified
Journal Article
Open access
PDF file
ACAndrea Giovanni Cutti
Andrea Giovanni Cutti
FMFederico Morosato
Federico Morosato
EGEmanuele Gruppioni
Emanuele Gruppioni
GTGREGORIO TETI
GREGORIO TETI
LMLorenzo De Michieli
Lorenzo De Michieli
CGCosimo Gentile
Cosimo Gentile
Conventional myoelectric prosthetic hands only offer a basic tri-digital pinch. Transradial amputees need to compensate for this lack of function with altered kinematics at the shoulder and trunk that might expose them to an increased risk of musculoskeletal injuries. A poly-articulated prosthetic hand may reduce the physical compensatory movements and close the gap between the sound and the prosthetic side. Six male transradial amputees completed four standardized reach-and-grasp activities with their tri-digital, poly-articulated and sound side hands. Trunk, shoulder girdle, scapula and humerus kinematics were measured with an optoelectronic system. Differences between hands were analyzed in terms of the amplitude of motion, the duration of the altered kinematics over the motion cycle, peak-to-peak amplitude and time to complete the activity. An overall score was defined, which assigned three points when the kinematics of a joint angle was altered for over 41% of the motion cycle, two points between 11 ÷ 40% and one point between 1 ÷ 10%; thus, a lower score indicates less variation from normal kinematics. Despite no changes in times, tri-digital vs. sound hand scored 93 points, tri-digital vs. poly-articulated hands scored 49 and poly-articulated vs. sound hand scored 28, supporting the hypotheses of the poly-articulated hand positively affects shoulder and trunk kinematics.

26 December 2022 in International Journal of Rehabilitation Research
Verified
Journal Article
Closed access
FMFederico Morosato
Federico Morosato
CGCosimo Gentile
Cosimo Gentile
ABArianna Di Bernardo
Arianna Di Bernardo
EGEmanuele Gruppioni
Emanuele Gruppioni
AMAntonella Miccio
Antonella Miccio
The Prosthetic Mobility Questionnaire (PMQ 2.0) represents a reliable solution for evaluating amputees’ self-perceived mobility. The study aimed to evaluate the perceived mobility of middle-aged users with a traumatic amputation using the PMQ 2.0 and to assess the influence of age, stump and phantom limb pain, amputation level, time since amputation, and prosthesis use on it. Fifty subjects were recruited. The median value of the score was higher than previously published reference values, reflecting the ‘active’ mobility status of the sample. The hours of prosthesis use per day explained about 21% of the variance of the questionnaire score and was a significant predictor of perceived mobility. Reference values for the recently developed PMQ 2.0 survey and relative to active, traumatic amputees were reported. As prosthesis use was a significant predictor of the amputees’ perceived mobility, prolonged use of the artificial limb should be always encouraged in clinical practice.