GREGORIO TETI

Prof. Dr. GREGORIO TETI


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
ACAndrea Giovanni Cutti
Andrea Giovanni Cutti
FMFederico Morosato
Federico Morosato
CGCosimo Gentile
Cosimo Gentile
FGFrancesca Gariboldi
Francesca Gariboldi
GHGiovanni Hamoui
Giovanni Hamoui
EGEmanuele Gruppioni
Emanuele Gruppioni
The design and fitting of prosthetic sockets can significantly affect the acceptance of an artificial limb by persons with lower limb amputations. Clinical fitting is typically an iterative process, which requires patients’ feedback and professional assessment. When feedback is unreliable due to the patient’s physical or psychological conditions, quantitative measures can support decision-making. Specifically, monitoring the skin temperature of the residual limb can provide valuable information regarding unwanted mechanical stresses and reduced vascularization, which can lead to inflammation, skin sores and ulcerations. Multiple 2D images to examine a real-life 3D limb can be cumbersome and might only offer a partial assessment of critical areas. To overcome these issues, we developed a workflow for integrating thermographic information on the 3D scan of a residual limb, with intrinsic reconstruction quality measures. Specifically, workflow allows us to calculate a 3D thermal map of the skin of the stump at rest and after walking, and summarize this information with a single 3D differential map. The workflow was tested on a person with transtibial amputation, with a reconstruction accuracy lower than 3 mm, which is adequate for socket adaptation. We expect the workflow to improve socket acceptance and patients’ quality of life.

5 February 2023 in Prosthesis
Verified
Journal Article
Open access
PDF file
ACAndrea Giovanni Cutti
Andrea Giovanni Cutti
FMFederico Morosato
Federico Morosato
EGEmanuele Gruppioni
Emanuele Gruppioni
GTGREGORIO TETI
GREGORIO TETI
LMLorenzo De Michieli
Lorenzo De Michieli
CGCosimo Gentile
Cosimo Gentile
Conventional myoelectric prosthetic hands only offer a basic tri-digital pinch. Transradial amputees need to compensate for this lack of function with altered kinematics at the shoulder and trunk that might expose them to an increased risk of musculoskeletal injuries. A poly-articulated prosthetic hand may reduce the physical compensatory movements and close the gap between the sound and the prosthetic side. Six male transradial amputees completed four standardized reach-and-grasp activities with their tri-digital, poly-articulated and sound side hands. Trunk, shoulder girdle, scapula and humerus kinematics were measured with an optoelectronic system. Differences between hands were analyzed in terms of the amplitude of motion, the duration of the altered kinematics over the motion cycle, peak-to-peak amplitude and time to complete the activity. An overall score was defined, which assigned three points when the kinematics of a joint angle was altered for over 41% of the motion cycle, two points between 11 ÷ 40% and one point between 1 ÷ 10%; thus, a lower score indicates less variation from normal kinematics. Despite no changes in times, tri-digital vs. sound hand scored 93 points, tri-digital vs. poly-articulated hands scored 49 and poly-articulated vs. sound hand scored 28, supporting the hypotheses of the poly-articulated hand positively affects shoulder and trunk kinematics.

24 March 2025 in Prosthesis
Verified
Journal Article
Open access
PDF file
ACAndrea Giovanni Cutti
Andrea Giovanni Cutti
FMFederico Morosato
Federico Morosato
EGEmanuele Gruppioni
Emanuele Gruppioni
GTGREGORIO TETI
GREGORIO TETI
LMLorenzo De Michieli
Lorenzo De Michieli
CGCosimo Gentile
Cosimo Gentile
“Institutional Review Board Statement” was not included in the original publication