Anirban Sur

Prof. Anirban Sur

Associate Prof. in Mechanical Engineering
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 August 2021 in Arabian Journal for Science and Engineering
Verified
Journal Article
Closed access
PDF file
SSSakshi Kokil- Shah
Sakshi Kokil- Shah
Anirban SurAnirban Sur
Anirban Sur
SDSanjay Darvekar
Sanjay Darvekar
MSMohanish Shah
Mohanish Shah

1 January 2020 in Materials Today: Proceedings
Verified
Journal Article
Closed access
Anirban SurAnirban Sur
Anirban Sur
RSRamesh P. Sah
Ramesh P. Sah
Sharnil PandyaSharnil Pandya
Sharnil Pandya

22 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Sharnil PandyaSharnil Pandya
Sharnil Pandya
HGHemant Ghayvat
Hemant Ghayvat
Anirban SurAnirban Sur
Anirban Sur
MAMUHAMMAD AWAIS
MUHAMMAD AWAIS
Ketan KotechaKetan Kotecha
Ketan Kotecha
GPGayatri Amit Pingale
Gayatri Amit Pingale
Air pollution has been a looming issue of the 21st century that has also significantly impacted the surrounding environment and societal health. Recently, previous studies have conducted extensive research on air pollution and air quality monitoring. Despite this, the fields of air pollution and air quality monitoring remain plagued with unsolved problems. In this study, the Pollution Weather Prediction System (PWP) is proposed to perform air pollution prediction for outdoor sites for various pollution parameters. In the presented research work, we introduced a PWP system configured with pollution-sensing units, such as SDS021, MQ07-CO, NO2-B43F, and Aeroqual Ozone (O3). These sensing units were utilized to collect and measure various pollutant levels, such as PM2.5, PM10, CO, NO2, and O3, for 90 days at Symbiosis International University, Pune, Maharashtra, India. The data collection was carried out between the duration of December 2019 to February 2020 during the winter. The investigation results validate the success of the presented PWP system. In the conducted experiments, linear regression and artificial neural network (ANN)-based AQI (air quality index) predictions were performed. Furthermore, the presented study also found that the customized linear regression methodology outperformed other machine-learning methods, such as linear, ridge, Lasso, Bayes, Huber, Lars, Lasso-lars, stochastic gradient descent (SGD), and ElasticNet regression methodologies, and the customized ANN regression methodology used in the conducted experiments. The overall AQI values of the air pollutants were calculated based on the summation of the AQI values of all the presented air pollutants. In the end, the web and mobile interfaces were developed to display air pollution prediction values of a variety of air pollutants.

13 October 2023 in Journal of the Brazilian Society of Mechanical Sciences and Engineering
Verified
Journal Article
Closed access
PDF file
SKSakshi Kokil-Shah
Sakshi Kokil-Shah
Anirban SurAnirban Sur
Anirban Sur
MSMohanish Shah
Mohanish Shah
SDSanjay K. Darvekar
Sanjay K. Darvekar

21 May 2021 in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
Verified
Journal Article
Closed access
PSPalash Soni
Palash Soni
Anirban SurAnirban Sur
Anirban Sur
VGVivek Kumar Gaba
Vivek Kumar Gaba
RSRAMESH PRASAD SAH
RAMESH PRASAD SAH
As adsorption refrigeration systems are powered by waste heat from automobile/industries and run by environment-friendly refrigerants, they have very promising cooling technology compared to vapor compression and absorption cooling systems. But due to large size, less performance and high installation cost, adsorption cooling systems have not yet been commercially popular. Literature review shows the physical adsorbent has poor adsorption capacity as compared to the chemical adsorbent. However, the salt swelling and agglomeration are the phenomenal challenges associated with chemical adsorption systems leading to reduction in the heat and mass transfer performances. To overcome the demerits of the physical and the chemical adsorbents, composite adsorbent systems have been developed to harness the potentiality of the adsorption capacity and increase the heat and mass transfer performances of adsorbent. In the present work the performance of different adsorption refrigeration system working on physical and chemical adsorbent has been discussed and compared on the basis of COP (Coefficient of Performance) and SCP (Specific cooling Power). A detailed comparative analysis has been provided between different composite adsorbents developed by using Silica-gel, Activated Carbon, Expanded Natural Graphite and Zeolite as a parent material. The performance of different composite adsorbents has been compared on the basis of thermal conductivity and adsorption capacity (of water, methanol, ethanol and CO2). Also, a novel composite adsorbent using polymeric binder (silica-gel and expanded natural graphite bound with polyvinyl alcohol) has been proposed and their physical properties are also discussed. In addition to this, three different methods of composite adsorbent materials preparation using silica-gel, activated carbon, zeolite with expanded natural graphite have been discussed. It is observed from the present study that the composite adsorbent of Metal Organic Frameworks shows better heat and mass transfer properties as compared to the conventional adsorbent. It is also observed that the performance of the adsorption refrigeration system can be improved significantly by developing high-performance composite adsorbents.

16 June 2020 in Particulate Science and Technology
Verified
Journal Article
Closed access
Anirban SurAnirban Sur
Anirban Sur
Sharnil PandyaSharnil Pandya
Sharnil Pandya
RSRamesh P. Sah
Ramesh P. Sah
Ketan KotechaKetan Kotecha
Ketan Kotecha
SNSwapnil Narkhede
Swapnil Narkhede
This paper presents a thermodynamic model for predicting the cooling performance of a single-bed single-stage silica gel/methanol adsorption refrigeration system. Solar heat was collected through flat plate collectors and then stored in a hot water tank. Desorber bed was heated by the hot water from the hot water tank. The temperature of the desorber bed was varied from 65 °C to 85 °C, and its effect on system performance was observed. A numerical model was developed on the basis of mass and energy balance equations, adsorption equilibrium, and kinetic equations (Dubinin–Astakhov equation) for predicting the performance of the adsorption refrigeration system under the said conditions for four major parts (adsorber, desorber, condenser, and evaporator). A programing code was written in FORTRAN for solving these equations under pre-defined material properties, and the simulation result was observed. A refrigeration effect of 577 kJ with a coefficient of performance (COP) of 0.38 could be produced for a maximum bed temperature of 90 °C, which was restricted up to 90 °C because after this temperature, the input increases more than the refrigeration effect, and COP values reduce due to a reduction in desorption mass.