RAMESH PRASAD SAH

Dr. RAMESH PRASAD SAH


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

15 April 2016 in International Journal of Sustainable Energy
Verified
Journal Article
Closed access
RSRAMESH PRASAD SAH
RAMESH PRASAD SAH
BCBiplab Choudhury
Biplab Choudhury
RDRanadip K. Das
Ranadip K. Das
In this study, a lumped parameter simulation model has been developed for analysis of the thermal performance of a single-stage two-bed adsorption chiller. Since silica gel has low regeneration temperature and water has high latent heat of vaporisation, silica gel–water pair has been chosen as the working pair of the adsorption chiller. Low-grade waste heat or solar heat at around 70–80°C can be used to run this adsorption chiller. In this model, the effects of operating parameters on the performance of the chiller have been studied. The simulated results show that the cooling capacity of the chiller has an optimum value of 5.95 kW for a cycle time of 1600 s with the hot, cooling, and chilled water inlet temperatures at 85°C, 25°C, and 14°C, respectively. The present model can be utilised to investigate and optimise adsorption chillers.

21 May 2021 in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
Verified
Journal Article
Closed access
PSPalash Soni
Palash Soni
Anirban SurAnirban Sur
Anirban Sur
VGVivek Kumar Gaba
Vivek Kumar Gaba
RSRAMESH PRASAD SAH
RAMESH PRASAD SAH
As adsorption refrigeration systems are powered by waste heat from automobile/industries and run by environment-friendly refrigerants, they have very promising cooling technology compared to vapor compression and absorption cooling systems. But due to large size, less performance and high installation cost, adsorption cooling systems have not yet been commercially popular. Literature review shows the physical adsorbent has poor adsorption capacity as compared to the chemical adsorbent. However, the salt swelling and agglomeration are the phenomenal challenges associated with chemical adsorption systems leading to reduction in the heat and mass transfer performances. To overcome the demerits of the physical and the chemical adsorbents, composite adsorbent systems have been developed to harness the potentiality of the adsorption capacity and increase the heat and mass transfer performances of adsorbent. In the present work the performance of different adsorption refrigeration system working on physical and chemical adsorbent has been discussed and compared on the basis of COP (Coefficient of Performance) and SCP (Specific cooling Power). A detailed comparative analysis has been provided between different composite adsorbents developed by using Silica-gel, Activated Carbon, Expanded Natural Graphite and Zeolite as a parent material. The performance of different composite adsorbents has been compared on the basis of thermal conductivity and adsorption capacity (of water, methanol, ethanol and CO2). Also, a novel composite adsorbent using polymeric binder (silica-gel and expanded natural graphite bound with polyvinyl alcohol) has been proposed and their physical properties are also discussed. In addition to this, three different methods of composite adsorbent materials preparation using silica-gel, activated carbon, zeolite with expanded natural graphite have been discussed. It is observed from the present study that the composite adsorbent of Metal Organic Frameworks shows better heat and mass transfer properties as compared to the conventional adsorbent. It is also observed that the performance of the adsorption refrigeration system can be improved significantly by developing high-performance composite adsorbents.

30 April 2025 in Discover Applied Sciences
Verified
Journal Article
Open access
PDF file
MSMohd Ahtesham Hussain Siddiqui
Mohd Ahtesham Hussain Siddiqui
PRPiush Raj
Piush Raj
SASamshad Ansari
Samshad Ansari
BDBiplab Das
Biplab Das
RSRAMESH PRASAD SAH
RAMESH PRASAD SAH
SDSAURABH DEWANGAN
SAURABH DEWANGAN
In underground mining, ventilation systems account for a significant portion of total power consumption. In this study, axial fans have been considered a primary target for energy-saving strategies. Affinity laws have been applied to analyze the energy-saving potential of axial fan speed reduction in underground mining ventilation systems. Real-time data monitoring was conducted to assess fan performance, energy consumption, and mechanical behaviour. Mathematical models were developed to evaluate the effects of speed reduction on mechanical wear, bearing life, and motor longevity. The results demonstrate that reducing fan speed by 10 and 50% save approximately 30.59 and 97.03 kW of power respectively and annual savings range from Rs 368,456 to Rs 2,337,453, depending on operational hours. Additionally, reducing fan speed improves mechanical wear performance, nearly doubles bearing life at 20% speed reduction, and significantly extends motor lifespan. By reducing fan speed using VFDs, substantial energy savings, improved equipment longevity, and lower operational costs can be achieved, contributing to both economic and environmental goals in mining operations.