An indirect competitive enzyme-linked immunosorbent assay (icELISA) with enhanced specificity for melamine in milk was developed. Three haptens of melamine with different spacer-arms were used to prepare different plate coating antigens. It was found that the icELISA show best sensitivity and specificity to melamine when using the coating antigen prepared by coupling 3-(4,6-diamino-1,6-dihydro-1,3,5-triazin-2-ylthio)propanoic acid (Hapten C) with ovalbumin (OVA). The 50% inhibitory concentration (IC50) value was 35.4 ng·mL−1, the limit of detection (LOD) was 8.9 ng·mL−1 and the detectable working range (20–80% inhibitory concentration) was from 14.9 to 108.5 ng·mL−1, respectively. Compared to the ELISA results previously reported, the developed icELISA in the present study showed a much lower cross-reactivity to cyromazine, a fly-killing insecticide widely used in vegetables and stables. Recoveries obtained from milk samples in this study were in agreement with those obtained using the HPLC-MS method, indicating the detection performance of the icELISA could meet the requirement of the residue limit set by the Codex Alimentarius Commission. Therefore, the developed immunoassay can be applied for the analysis of melamine presented in milk.
Nanobodies are one-tenth the size of conventional antibodies and are naturally obtained from the atypical heavy-chain-only antibodies present in camelids. Their small size, high solubility, high stability, and strong resilience to organic solvents facilitate their use as novel analytical reagents in immunochemistry. In this study, specific nanobodies against pesticide carbofuran were isolated and characterized from an immunized library via phage display platform. We further established an indirect competitive enzyme-linked immunosorbent assay (ELISA) using nanobody Nb316 to detect carbofuran in vegetable and fruit samples. The results showed a half-maximal inhibitory concentration (IC50) of 7.27 ng/mL and a detection limit of 0.65 ng/mL. A simplified sample pretreatment procedure omitting the evaporation of organic solvent was used. The averaged recovery rate of spiked samples ranged between 82.3% and 103.9%, which correlated with that of standard UPLC–MS/MS method. In conclusion, a nanobody with high specificity for carbofuran was characterized, and a nanobody-based sensitive immunoassay for simple and rapid detection of carbofuran in real samples was validated.
The haptens 4-[[(2,3-dihydro-2,2-dimethyl-7-benzofuranyloxy)carbonyl]-amino]butanoic acid (BFNB) and 6-[((2,3-dihydro-2,2-dimethyl-7-benzofuranyloxy)-carbonylamino]hexanoic acid (BFNH) were synthesized and then used to develop a rapid,specific and sensitive ELISA method to determine residues of the pesticide carbofuran in avariety of matrices. A hybridoma cell line (5D3) producing anti-carbofuran monoclonalantibodies (MAbs) was also established. Based on the MAbs in combination with theheterologous hapten BFNH coupled to either horseradish peroxidase (HRP) or ovalbumin(OVA), four ELISAs (formats I-IV) for the quantification of carbofuran were developedand compared. Among them, the optimized format II (the conjugate-coated directcompetitive ELISA) showed the best characteristics, with an IC50 value of 18.49 ng/mL, alimit of detection of 0.11 ng/mL and the shortest assay time (1 h). This ELISA method wasthen applied to the determinations of carbofuran in environmental water, soil and foodsamples. The relative standard deviations (R.S.D.s) ranged from 1.8% to 21.3% and themean recoveries were 104.6%, 108.3%, 106.3% and 100.1% for water, soil, lettuce andcabbage, respectively. Thus, the ELISA method of format II exhibited the potential todevelop commercial ELISA kits for a rapid detection of carbofuran for human health andenvironmental safety.
In this work, a monoclonal antibody-based indirect competitive enzyme-linked immunosorbent assay (icELISA) was established to detect tylosin and tilmicosin in milk and water samples. A sensitive and specific monoclonal antibody was prepared by rational designed hapten, which was achieved by directly oxidizing the aldehyde group on the side chain of tylosin to the carboxyl group. Under the optimized conditions, the linear range of icELISA for tylosin and tilmicosin were 1.3 to 17.7 ng/mL and 2.0 to 47.4 ng/mL, with half-maximal inhibition concentration (IC50) values of 4.7 and 9.6 ng/mL, respectively. The cross-reactivity with other analogues of icELISA was less than 0.1%. The average recoveries of icELISA for tylosin and tilmicosin ranged from 76.4% to 109.5% in milk and water samples. Besides, the detection results of icELISA showed good correlations with HPLC-MS/MS. The proposed icELISA was satisfied for rapid and specific screening of tylosin and tilmicosin residues in milk and water samples.