Prakan Thanasrisuebwong

Dr. Prakan Thanasrisuebwong


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
PTPrakan Thanasrisuebwong
Prakan Thanasrisuebwong
TKTharathip Kulchotirat
Tharathip Kulchotirat
Chuchai AnunmanaChuchai Anunmana
Chuchai Anunmana
Thanasrisuebwong P, et al. J Adv Prosthodont. 2021 Apr;13(2):107-116. https://doi.org/10.4047/jap.2021.13.2.107

16 May 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
PTPrakan Thanasrisuebwong
Prakan Thanasrisuebwong
JJJulian Jones
Julian Jones
SESalita Eiamboonsert
Salita Eiamboonsert
NRNisarat Ruangsawasdi
Nisarat Ruangsawasdi
BJBundhit Jirajariyavej
Bundhit Jirajariyavej
PNParichart Naruphontjirakul
Parichart Naruphontjirakul
Zn-containing dense monodispersed bioactive glass nanoparticles (Zn-BAGNPs) have been developed to deliver therapeutic inorganic trace elements, including Si, Ca, Sr, and Zn, to the cells through the degradation process, as delivery carriers for stimulating bone regeneration because of their capacity to induce osteogenic differentiation. The sol–gel-derived dense silica nanoparticles (SiO2-NPs) were first synthesized using the modified Stöber method, prior to incorporating therapeutic cations through the heat treatment process. The successfully synthesized monodispersed Zn-BAGNPs (diameter of 130 ± 20 nm) were homogeneous in size with spherical morphology. Ca, Sr and Zn were incorporated through the two-step post-functionalization process, with the nominal ZnO ratio between 0 and 2 (0, 0.5, 1.0, 1.5 and 2.0). Zn-BAGNPs have the capacity for continuous degradation and simultaneous ion release in SBF and PBS solutions due to their amorphous structure. Zn-BAGNPs have no in vitro cytotoxicity on the murine pre-osteoblast cell (MC3T3-E1) and periodontal ligament stem cells (PDLSCs), up to a concentration of 250 µg/mL. Zn-BAGNPs also stimulated osteogenic differentiation on PDLSCs treated with particles, after 2 and 3 weeks in culture. Zn-BAGNPs were not toxic to the cells and have the potential to stimulate osteogenic differentiation on PDLSCs. Therefore, Zn-BAGNPs are potential vehicles for therapeutic cation delivery for applications in bone and dental regenerations.

3 November 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Chuchai AnunmanaChuchai Anunmana
Chuchai Anunmana
CUChananchida Ueawitthayasuporn
Chananchida Ueawitthayasuporn
SKSirichai Kiattavorncharoen
Sirichai Kiattavorncharoen
PTPrakan Thanasrisuebwong
Prakan Thanasrisuebwong
Various three-dimensional (3D) printing technologies are commercially available on the market, but the influence of different technologies on the accuracy of implant-guided surgery is unclear. Thus, three printing technologies: Stereolithographic (SLA), Digital light processing (DLP), and Polyjet were evaluated in this study. An entire 30 polyurethane models replicated the clinical situation. Ten surgical guides were printed by SLA, DLP, and PolyJet. Then, implant-guided surgery was performed, and their accuracy outcomes were measured concerning angular deviation, 3D deviation at the entry point, and apex. On top of that, the total processing time was also compared. For the angular deviation, the mean deviation was not statistically significant among all technologies. For the 3D deviation, PolyJet was statistically more accurate than DLP (p = 0.002) and SLA (p = 0.017) at the entry point. PolyJet was also statistically more accurate than DLP (p = 0.007) in regards to 3D deviation at the apex. Within the limitation of this study, the deviations from the experiment showed that PolyJet had the best outcome regarding the 3D deviations at the entry point and at the apex, meanwhile, the DLP printer had the shortest processing time.

16 February 2023 in Materials
Verified
Journal Article
Open access
PDF file
VSVishal Sehgal
Vishal Sehgal
NRNisarat Ruangsawasdi
Nisarat Ruangsawasdi
SKSirichai Kiattavorncharoen
Sirichai Kiattavorncharoen
Sompop BencharitSompop Bencharit
Sompop Bencharit
PTPrakan Thanasrisuebwong
Prakan Thanasrisuebwong
Different collagen barrier membranes come in various sources and crosslinking that may affect barrier function and tissue integration. This study investigated barrier function and tissue integration of the three different collagen membranes (Jason®: porcine pericardium, GENOSS: bovine tendon, and BioMend® Extend: cross-linked bovine tendon) with human gingival fibroblasts. The barrier function and tissue integration properties were determined under confocal microscopy. Morphological characteristics were observed using scanning electron microscopy. Our results showed that all collagen membranes allowed a small number of cells to migrate, and the difference in barrier function ability was not significant. The cross-linked characteristics did not improve barrier ability. The native collagen membrane surfaces allowed evenly scattered proliferation of HGF, while the cross-linked collagen membrane induced patchy proliferation. Statistically significant differences in cell proliferation were found between Jason and BioMend Extend membranes (p = 0.04). Scanning electron microscope showed a compact membrane surface at the top, while the bottom surfaces displayed interwoven collagen fibers, which were denser in the crosslinked collagen membranes. Within the limitations of this study, collagen membranes of different origins and physical properties can adequately prevent the invasion of unwanted cells. Native collagen membranes may provide a better surface for gingival cell attachment and proliferation.

21 September 2023 in PLOS ONE
Verified
Journal Article
Open access
PDF file
PPPobploy Petchmedyai
Pobploy Petchmedyai
PTPrakan Thanasrisuebwong
Prakan Thanasrisuebwong
In implant dentistry, the advent of intraoral scanning technology has revolutionized traditional clinical processes by streamlining procedures and ensuring predictable treatment outcomes. However, achieving accurate virtual implant positions using intraoral scanners and scan bodies can be influenced by various clinical and laboratory factors. This study aims to investigate the impact of scan body image capture deficiency and scan body alignment methods in computer-aided design (CAD) software on the accuracy of virtual implant positions, particularly in different implant depths. Three stereolithographic half-arch implant models with different implant depths were prepared, representing three scenarios of scan body exposure: full exposed scan body, 2/3 exposed scan body, and 1/3 exposed scan body. The scan body image capture deficiency and alignment methods were simulated using CAD software. The deviation of virtual implant positions obtained from different scenarios were evaluated using 3D analysis software. The highest angular and linear deviation (0.237±0.059 degrees, 0.084±0.068 mm) were found in the 1/4 upper and lower part scan body deficiency using the 1-point alignment method in the 1/3 exposed scan body. Two-way ANOVA analysis revealed significant effects of scan deficiency on virtual implant position deviations across all scan body exposures, except for the linear deviation when the scan body was exposed 2/3 of its length. Furthermore, scan deficiencies in the 1/4 upper and lower parts of the scan body significantly affected implant angular deviation regardless of scan body exposure, while implant linear deviation was specifically affected when the scan body was exposed to only 1/3 of its total length. Deficiencies in scan body acquisition, particularly in deep soft tissue situations, can lead to deviations in both angular and linear positioning of virtual implants. Employing appropriate scan body alignment methods such as a 3-point alignment approach demonstrates better accuracy compared to a 1-point alignment.

22 October 2025 in European Journal of Dentistry
Verified
Journal Article
Open access
PDF file
RMRann Manlerd
Rann Manlerd
BJBundhit Jirajariyavej
Bundhit Jirajariyavej
NRNisarat Ruangsawasdi
Nisarat Ruangsawasdi
PTPrakan Thanasrisuebwong
Prakan Thanasrisuebwong
Socket sealing is a technique for alveolar ridge preservation following tooth extraction. Leukocyte and platelet-rich fibrin (L-PRF), an autologous platelet-derived material rich in growth factors, is used to support healing. However, its benefits for soft tissue healing compared with collagen sponge or spontaneous healing remain unclear. This study evaluated soft tissue healing outcomes, wound margin distance, inflammation, postoperative pain, and wound closure area, among sockets treated with L-PRF membrane, collagen sponge, or spontaneous healing. A randomized controlled clinical trial was conducted on 45 extraction sites at the Faculty of Dentistry, Mahidol University, Bangkok, Thailand. Sockets were randomly assigned to L-PRF sealing, collagen sponge sealing, or spontaneous healing. Primary outcomes included wound margin distance reduction percentage, soft tissue healing index, and postoperative pain. The secondary outcome was wound closure area reduction percentage between the L-PRF and collagen sponge groups. Measurements were recorded postoperatively and on days 7, 14, and 21. Pain scores were recorded daily for 1 week. Age, sex, tooth position, and arch were evaluated as covariates. One-way ANOVA with least significant difference post-hoc test was used for primary outcomes, and an independent t-test was used for secondary outcomes (p < 0.05). Forty-five teeth were enrolled. Three teeth from the collagen sponge group were excluded due to infection and loss to follow-up; three additional teeth were recruited using the original allocation and randomization protocol. On day 7, L-PRF showed a significantly superior soft tissue healing index than collagen sponge (p = 0.002, 95% CI: [0.28, 1.18]) and spontaneous healing (p = 0.002, 95% CI: [0.28, 1.18]). On day 5, L-PRF reduced pain more than collagen sponge (p = 0.036, 95% CI: [0.04, 1.03]) and spontaneous healing (p = 0.026, 95% CI: [0.07, 1.06]). No significant differences in wound closure distance reduction percentage or wound area reduction percentage were observed among the groups. L-PRF improved soft tissue healing and reduced postoperative pain within the first week, but showed no added benefit in wound closure compared with collagen sponge or spontaneous healing. L-PRF may support short-term symptom relief but not enhanced post-extraction soft tissue regeneration at the clinical relevance level.