Bundhit Jirajariyavej

Dr. Bundhit Jirajariyavej

Mahidol University, Bangkok, Krung Thep Maha Nakhon, Thailand
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 June 2022 in Molecules
Verified
Journal Article
Open access
PDF file
ACAtitiya Chindarungruangrat
Atitiya Chindarungruangrat
TETrinuch Eiampongpaiboon
Trinuch Eiampongpaiboon
BJBundhit Jirajariyavej
Bundhit Jirajariyavej
This study aimed to examine the retentive characteristics of each retentive element material and the effects from thermocycling using the two implant-retained mandibular overdenture model. Two stud abutments and three retentive element materials; nylon, polyetheretherketone (PEEK) and polyvinylsiloxane (PVS) were used in this study. Four tested groups, with a total of 40 overdentures, were fabricated, including a Locator® abutment with nylon retention insert (NY), Novaloc® abutment with PEEK retention insert (PK), Locator® abutment with PVS retention insert (RL), and Novaloc® abutment with PVS retention insert (RN). The retentive force (N) was measured before thermocycling, and at 2500, 5000, and 10,000 cycles after thermocycling. Significant changes in the percentage of retention loss were found in the NY and PK groups (p < 0.05) at 6 and 12 months for the RL group (p < 0.05) after artificial aging. The RN group exhibited a constant retentive force (p > 0.05). The tendency of the percentage of retention loss significantly increased for PEEK, nylon, and PVS silicone over time. The results of the present study implied that retentive element materials tend to lose their retentive capability as a result of thermal undulation and water dispersion. Nylon and PEEK, comprising strong polar groups in polymer chains, showed a higher rate of retention loss than polyvinylsiloxane.

22 June 2022 in Journal of Prosthodontics
Verified
Journal Article
Open access
PTPrakan Thanasrisuebwong
Prakan Thanasrisuebwong
APAtiphan Pimkhaokham
Atiphan Pimkhaokham
BJBundhit Jirajariyavej
Bundhit Jirajariyavej
Sompop BencharitSompop Bencharit
Sompop Bencharit
Purpose: Aggressive implant macrothread designs have been widely used. However, the effects of the aggressive thread design on the accuracy of static guided surgery, especially in a case of narrow residual ridge, have not been well‐studied. The aim of this study was to evaluate the effects of two different implant macrothread designs and the residual ridge widths on the accuracy of tooth‐supported static guided implant surgery.Materials and methods: Forty implant fixtures with two different macrodesigns: a conventional thread design bone level tapered (BLT), and an aggressive thread design bone level tapered (BLX) were placed in 40 simulated polyurethane models with narrow and wide residual ridges. The placed implant positions were compared with the planned implant position and angulational deviation, as well as three‐dimensional (3D) deviations at the entry and apex of the implant were measured. One‐way ANOVA with Tukey's multiple comparisons (ɑ = 0.05) were used to determine level of significance between the mean and variance deviation values. 95% confidence intervals and box plots were used to demonstrate the means and ranges of precision.Results: In terms of angulational deviation, there was no statistically significant difference in the mean deviations for both types of implants, p = 1.55 and p = 0.84 for wide and narrow ridge groups, respectively. However, the range of deviation was much larger in the narrow ridge of the BLX group compared to the BLT group. In both narrow ridge and wide ridge, the BLX group had lower mean 3D deviation values at both the entry and the apex with statistically significant differences for both entry point of the wide ridge (p = 0.027) and narrow ridge (p = 0.022) as well as at the apex of the wide ridge (p = 0.006) but not the apex of the narrow ridge (p = 0.142).Conclusion: The aggressive larger thread design of dental implants may influence the accuracy of implant placement more than the ridge dimension.

22 October 2025 in European Journal of Dentistry
Verified
Journal Article
Open access
PDF file
RMRann Manlerd
Rann Manlerd
BJBundhit Jirajariyavej
Bundhit Jirajariyavej
NRNisarat Ruangsawasdi
Nisarat Ruangsawasdi
PTPrakan Thanasrisuebwong
Prakan Thanasrisuebwong
Socket sealing is a technique for alveolar ridge preservation following tooth extraction. Leukocyte and platelet-rich fibrin (L-PRF), an autologous platelet-derived material rich in growth factors, is used to support healing. However, its benefits for soft tissue healing compared with collagen sponge or spontaneous healing remain unclear. This study evaluated soft tissue healing outcomes, wound margin distance, inflammation, postoperative pain, and wound closure area, among sockets treated with L-PRF membrane, collagen sponge, or spontaneous healing. A randomized controlled clinical trial was conducted on 45 extraction sites at the Faculty of Dentistry, Mahidol University, Bangkok, Thailand. Sockets were randomly assigned to L-PRF sealing, collagen sponge sealing, or spontaneous healing. Primary outcomes included wound margin distance reduction percentage, soft tissue healing index, and postoperative pain. The secondary outcome was wound closure area reduction percentage between the L-PRF and collagen sponge groups. Measurements were recorded postoperatively and on days 7, 14, and 21. Pain scores were recorded daily for 1 week. Age, sex, tooth position, and arch were evaluated as covariates. One-way ANOVA with least significant difference post-hoc test was used for primary outcomes, and an independent t-test was used for secondary outcomes (p < 0.05). Forty-five teeth were enrolled. Three teeth from the collagen sponge group were excluded due to infection and loss to follow-up; three additional teeth were recruited using the original allocation and randomization protocol. On day 7, L-PRF showed a significantly superior soft tissue healing index than collagen sponge (p = 0.002, 95% CI: [0.28, 1.18]) and spontaneous healing (p = 0.002, 95% CI: [0.28, 1.18]). On day 5, L-PRF reduced pain more than collagen sponge (p = 0.036, 95% CI: [0.04, 1.03]) and spontaneous healing (p = 0.026, 95% CI: [0.07, 1.06]). No significant differences in wound closure distance reduction percentage or wound area reduction percentage were observed among the groups. L-PRF improved soft tissue healing and reduced postoperative pain within the first week, but showed no added benefit in wound closure compared with collagen sponge or spontaneous healing. L-PRF may support short-term symptom relief but not enhanced post-extraction soft tissue regeneration at the clinical relevance level.

2 June 2025 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
BJBundhit Jirajariyavej
Bundhit Jirajariyavej
POPanchanit Ounvorawong
Panchanit Ounvorawong
SPSuchaya Pornprasertsuk-Damrongsri
Suchaya Pornprasertsuk-Damrongsri
PVPorntida Visuttiwattanakorn
Porntida Visuttiwattanakorn
SSSalisa Sriyarun
Salisa Sriyarun
PPPobploy Petchmedyai
Pobploy Petchmedyai
Background: Accurate occlusal registration is critical for successful dental implant treatments. Traditional mechanical articulation provides insight into occlusal relationships but cannot replicate complex mandibular movements accurately. CAD/CAM advancements, including virtual articulators, enable dynamic occlusion analysis using either average-value settings or individualized mandibular movement data, depending on the system used. Patient Specific Motion (PSM) technology, using intraoral scanners to record actual mandibular movements, offers enhanced functional occlusal design. Despite these advancements, challenges such as patient movement and limited residual dentition affect accuracy, highlighting the need for further research into dynamic occlusal registration methods. This study investigates the impact of different occlusal registration techniques on prosthesis design under varying conditions of missing teeth. Methods: Ten participants were examined in an in-vivo study comparing the accuracy of three occlusal registration methods: 1) Static Occlusal Registration (SA), Dynamic Occlusal Registration including 2) Virtual Articulator (VA), and 3) Patient-Specific Motion (PSM). The tested models were simulated by digital tooth removal in three conditions of missing teeth, and 3-D deviations of occlusal contacts recorded before (reference) and after (tested) virtually tooth removal were assessed to reflect the accuracy of occlusal morphology reproduction. Results: The root mean square (RMS), and percentage of In-Tolerance and Out-of-Tolerance of divided occlusal surface areas were analyzed and visualized using a color-coded deviation map. Statistically significant differences were observed between static and dynamic methods (p < 0.05), though no significant differences between the two dynamic methods. The PSM method exhibited the highest RMS values and a trend of negative deviations, while the VA method demonstrated the largest positive deviations. In terms of the effect of missing teeth, greater deviations were observed in models with more extensive tooth loss, particularly at the functional cusp areas, suggesting reduced accuracy in complex occlusal conditions. Conclusions: This study confirms that different occlusal registration methods (STA, VA, PSM) significantly influence prosthesis design, with all showing clinically acceptable outcomes. PSM demonstrated advantages in customization and may improve treatment precision. Occlusal accuracy declined as the number of remaining teeth decreased, highlighting the importance of maintaining sufficient tooth contacts for reliable digital prosthesis design in partially edentulous cases. Trial registration: This study was retrospectively registered and obtained approval from the TCTR Committee (TCTR20241116001, Date: 16/11/2024).