marcello nuvoli

marcello nuvoli


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2019 in Sensors
Verified
Journal Article
Open access
PDF file
violeta lazicvioleta lazic
violeta lazic
APAntonio Palucci
Antonio Palucci
LDLuigi De Dominicis
Luigi De Dominicis
MNmarcello nuvoli
marcello nuvoli
MPMarco Pistilli
Marco Pistilli
Salvatore AlmavivaSalvatore Almaviva
Salvatore Almaviva
Here, we describe an innovative Integrated Laser Sensor (ILS) that combines four spectroscopic techniques and two vision systems into a unique, transportable device. The instrument performs Raman and Laser-Induced Fluorescence (LIF) spectroscopy excited at 355 nm and Laser-Induced Breakdown Spectroscopy (LIBS) excited at 1064 nm, and it also detects Laser Scattering (LS) from the target under illumination at 650 nm. The combination of these techniques supplies information about: material change from one scanning point to another, the presence of surface contaminants, the molecular and elemental composition of top target layers. Switching between the spectroscopic techniques and the laser wavelengths is fully automatic. The instrument is equipped with an autofocus and it performs scanning with a chosen grid density over an interactively-selected target area. Alternative to the spectroscopic measurements, it is possible to switch the instrument to a high magnification target viewing. The working distances tested until now are between 8.5 and 30 m. The instrument is self-powered and remotely controlled via wireless communication. The ILS has been fully developed at ENEA for security applications and it was successfully tested in two outdoor campaigns where an automatic recognition of areas containing explosives in traces had been implemented. The strategies for the identification of nitro-compounds placed on various substrates as fingerprints and the results obtained at a working distance of 10 m are discussed in the following.


22 December 2015 in Sensors
Verified
Journal Article
Open access
PDF file
RCRoberto Chirico
Roberto Chirico
Salvatore AlmavivaSalvatore Almaviva
Salvatore Almaviva
FCFrancesco Colao
Francesco Colao
Luca FioraniLuca Fiorani
Luca Fiorani
MNmarcello nuvoli
marcello nuvoli
APAntonio Palucci
Antonio Palucci
A new Raman-based apparatus for proximal detection of energetic materials on people, was developed and tested for the first time. All the optical and optoelectronics components of the apparatus, as well as their optical matching, were carefully chosen and designed to respect international eye-safety regulations. In this way, the apparatus is suitable for civil applications on people in public areas such as airports and metro or railway stations. The acquisition software performs the data analysis in real-time to provide a fast response to the operator. Moreover, it allows for deployment of the apparatus either as a stand alone device or as part of a more sophisticated warning system architecture made up of several sensors. Using polyamide as substrate, the apparatus was able to detect surface densities of ammonium nitrate (AN), 2-methyl-1,3,5-trinitrobenzene (TNT), 3-nitrooxy-2,2-bis(nitrooxymethyl)propyl] nitrate (PETN) and urea nitrate (UN) in the range of 100–1000 μg/cm2 at a distance of 6.4 m using each time a single laser pulse of 3 mJ/cm2. The limit of detection calculated for AN is 289 μg/cm2. AN and UN provided the highest percentages of true positives (>82% for surface densities of 100–400 μg/cm2 and fingerprints) followed by TNT and PETN (17%–70% for surface densities of 400–1000 μg/cm2 and fingerprints).

11 January 2020 in Sensors
Verified
Journal Article
Open access
PDF file
ELEONORA ARUFFOELEONORA ARUFFO
ELEONORA ARUFFO
ACAndrea Chiuri
Andrea Chiuri
Federico AngeliniFederico Angelini
Federico Angelini
FAFlorinda Artuso
Florinda Artuso
DCDario Cataldi
Dario Cataldi
APAntonio Palucci
Antonio Palucci
An innovative hyperspectral LIDAR instrument has been developed for applications in marine environment monitoring research activities, remotely detecting the fluorescence spectra produced in the spectral interval between 400 nm and 720 nm. The detection system is composed by a custom made photomultiplier charge integrating and measuring (CIM) unit, which makes automatic background signal subtraction, and a liquid crystal tunable filter (LCTF). The new instrument therefore has hyperspectral resolution and allows automatic background subtraction; it is compact and automated by custom software that permit to adapt the instrument properties depending on the environmental conditions. Laboratory tests to characterize the instrument performance have been carried out, concluding that this sensor can be employed in remote sites for Chl-a detection.

3 March 2017 in Geosciences
Verified
Journal Article
Open access
PDF file
SSSimone Santoro
Simone Santoro
Stefano ParracinoStefano Parracino
Stefano Parracino
Luca FioraniLuca Fiorani
Luca Fiorani
RDRoberto D'Aleo
Roberto D'Aleo
EFEnzo Di Ferdinando
Enzo Di Ferdinando
AAAlessandro Aiuppa
Alessandro Aiuppa
Volcanic eruptions are often preceded by precursory increases in the volcanic carbon dioxide (CO2) flux. Unfortunately, the traditional techniques used to measure volcanic CO2 require near-vent, in situ plume measurements that are potentially hazardous for operators and expose instruments to extreme conditions. To overcome these limitations, the project BRIDGE (BRIDging the gap between Gas Emissions and geophysical observations at active volcanoes) received funding from the European Research Council, with the objective to develop a new generation of volcanic gas sensing instruments, including a novel DIAL-Lidar (Differential Absorption Light Detection and Ranging) for remote (e.g., distal) CO2 observations. Here we report on the results of a field campaign carried out at Mt. Etna from 28 July 2016 to 1 August 2016, during which we used this novel DIAL-Lidar to retrieve spatially and temporally resolved profiles of excess CO2 concentrations inside the volcanic plume. By vertically scanning the volcanic plume at different elevation angles and distances, an excess CO2 concentration of tens of ppm (up to 30% above the atmospheric background of 400 ppm) was resolved from up to a 4 km distance from the plume itself. From this, the first remotely sensed volcanic CO2 flux estimation from Etna’s northeast crater was derived at ≈2850–3900 tons/day. This Lidar-based CO2 flux is in fair agreement with that (≈2750 tons/day) obtained using conventional techniques requiring the in situ measurement of volcanic gas composition.

7 September 2023 in Sensors
Verified
Journal Article
Open access
PDF file
ACAndrea Chiuri
Andrea Chiuri
RCRoberto Chirico
Roberto Chirico
Federico AngeliniFederico Angelini
Federico Angelini
FAFabrizio Andreoli
Fabrizio Andreoli
IMIvano Menicucci
Ivano Menicucci
violeta lazicvioleta lazic
violeta lazic
Stand-off detection of latent traces avoids the scene alteration that might occur during close inspection by handheld forensic lights. Here, we describe a novel sensor, named Crime Light Imaging (CLI), designed to perform high-resolution photography of targets at a distance of 2–10 m and to visualize some common latent traces. CLI is based on four high-power illumination LEDs and one color CMOS camera with a motorized objective plus frontal filters; the LEDs and camera could be synchronized to obtain short-exposure images weakly dependent on the ambient light. The sensor is integrated into a motorized platform, providing the target scanning and necessary information for 3D scene reconstruction. The whole system is portable and equipped with a user-friendly interface. The preliminary tests of CLI on fingerprints at distance of 7 m showed an excellent image resolution and drastic contrast enhancement under green LED light. At the same distance, a small (1 µL) blood droplet on black tissue was captured by CLI under NIR LED, while a trace from 15 µL semen on white cotton became visible under UV LED illumination. These results represent the first demonstration of true stand-off photography of latent traces, thus opening the way for a completely new approach in crime scene forensic examination.