Marco Pistilli

Dr. Marco Pistilli


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2019 in Sensors
Verified
Journal Article
Open access
PDF file
violeta lazicvioleta lazic
violeta lazic
APAntonio Palucci
Antonio Palucci
LDLuigi De Dominicis
Luigi De Dominicis
MNmarcello nuvoli
marcello nuvoli
MPMarco Pistilli
Marco Pistilli
Salvatore AlmavivaSalvatore Almaviva
Salvatore Almaviva
Here, we describe an innovative Integrated Laser Sensor (ILS) that combines four spectroscopic techniques and two vision systems into a unique, transportable device. The instrument performs Raman and Laser-Induced Fluorescence (LIF) spectroscopy excited at 355 nm and Laser-Induced Breakdown Spectroscopy (LIBS) excited at 1064 nm, and it also detects Laser Scattering (LS) from the target under illumination at 650 nm. The combination of these techniques supplies information about: material change from one scanning point to another, the presence of surface contaminants, the molecular and elemental composition of top target layers. Switching between the spectroscopic techniques and the laser wavelengths is fully automatic. The instrument is equipped with an autofocus and it performs scanning with a chosen grid density over an interactively-selected target area. Alternative to the spectroscopic measurements, it is possible to switch the instrument to a high magnification target viewing. The working distances tested until now are between 8.5 and 30 m. The instrument is self-powered and remotely controlled via wireless communication. The ILS has been fully developed at ENEA for security applications and it was successfully tested in two outdoor campaigns where an automatic recognition of areas containing explosives in traces had been implemented. The strategies for the identification of nitro-compounds placed on various substrates as fingerprints and the results obtained at a working distance of 10 m are discussed in the following.

18 June 2015 in Sensors
Verified
Journal Article
Open access
PDF file
Adriana PuiuAdriana Puiu
Adriana Puiu
Luca FioraniLuca Fiorani
Luca Fiorani
IMIvano Menicucci
Ivano Menicucci
MPMarco Pistilli
Marco Pistilli
ALAntonia Lai
Antonia Lai
In this work, we present a newly developed submersible spectrofluorometer (patent pending) applied to real-time sensing of water quality, suitable for monitoring some important indicators of the ecological status of natural waters such as chlorophyll-a, oil and protein-like material. For the optomechanical realization of the apparatus, a novel conceptual design has been adopted in order to avoid filters and pumps while maintaining a high signal-to-noise ratio. The elimination of filters and pumps has the advantage of greater system simplicity and especially of avoiding the risk of sample degradation. The use of light-emitting diodes as an excitation source instead of Xe lamps or laser diodes helped save on size, weight, power consumption and costs. For sensor calibration we performed measurements on water samples with added chlorophyll prepared in the laboratory. The sensor functionality was tested during field campaigns conducted at Albano Lake in Latium Region of Italy as well as in the Herzliya Harbor, a few kilometers North East of Tel Aviv in Israel. The obtained results are reported in the paper. The sensitivity achieved for chlorophyll-a detection was found to be at least 0.2 µg/L.

11 January 2020 in Sensors
Verified
Journal Article
Open access
PDF file
ELEONORA ARUFFOELEONORA ARUFFO
ELEONORA ARUFFO
ACAndrea Chiuri
Andrea Chiuri
Federico AngeliniFederico Angelini
Federico Angelini
FAFlorinda Artuso
Florinda Artuso
DCDario Cataldi
Dario Cataldi
APAntonio Palucci
Antonio Palucci
An innovative hyperspectral LIDAR instrument has been developed for applications in marine environment monitoring research activities, remotely detecting the fluorescence spectra produced in the spectral interval between 400 nm and 720 nm. The detection system is composed by a custom made photomultiplier charge integrating and measuring (CIM) unit, which makes automatic background signal subtraction, and a liquid crystal tunable filter (LCTF). The new instrument therefore has hyperspectral resolution and allows automatic background subtraction; it is compact and automated by custom software that permit to adapt the instrument properties depending on the environmental conditions. Laboratory tests to characterize the instrument performance have been carried out, concluding that this sensor can be employed in remote sites for Chl-a detection.

24 February 2024 in Sensors
Verified
Journal Article
Open access
PDF file
violeta lazicvioleta lazic
violeta lazic
FAFabrizio Andreoli
Fabrizio Andreoli
Salvatore AlmavivaSalvatore Almaviva
Salvatore Almaviva
MPMarco Pistilli
Marco Pistilli
IMIvano Menicucci
Ivano Menicucci
RCRoberto Chirico
Roberto Chirico
In this work, we present a compact LIBS sensor developed for characterization of samples on a crime scene following requirements of law enforcement agencies involved in the project. The sensor operates both in a tabletop mode, for aside measurements of swabbed materials or taken fragments, and in handheld mode where the sensor head is pointed directly on targets at the scene. The sensor head is connected via an umbilical to an instrument box that could be battery-powered and contains also a color camera for sample visualization, illumination LEDs, and pointing system for placing the target in focus. Here we describe the sensor’s architecture and functionalities, the optimization of the acquisition parameters, and the results of some LIBS measurements. On nano-plotted traces at silica wafer and in optimized conditions, for most of the elements the detection limits, in term of the absolute element masses, were found to be below 10 picograms. We also show results obtained on some representative materials, like fingerprints, swabbed soil and gunshot residue, varnishes on metal, and coated plastics. The last, solid samples were used to evaluate the depth profiling capabilities of the instrument, where the recognition of all four car paint layers was achieved.

Verified
Journal Article
Open access
PDF file
Salvatore AlmavivaSalvatore Almaviva
Salvatore Almaviva
Lidia BaiamonteLidia Baiamonte
Lidia Baiamonte
MPMarco Pistilli
Marco Pistilli
In current and future fusion devices, detecting hydrogen isotopes, particularly tritium and deuterium, implanted or redeposited on the surface of Plasma-Facing Components (PFCs) will be increasingly important to ensure safe machine operations. The Laser-Induced Breakdown Spectroscopy (LIBS) technique has proven capable of performing this task directly in situ, without handling or removing PFCs, thus limiting analysis times and increasing the machine’s duty cycle. To increase sensitivity and the ability to discriminate between isotopes, LIBS analysis can be performed under different background gases at atmospheric pressure, such as air, He, and Ar. In this work, we present the results obtained on tungsten coatings enriched with deuterium and/or hydrogen as a deuterium–tritium nuclear fuel simulant, measured with the LIBS technique in air, He, and Ar at atmospheric pressure, and discuss the pros and cons of their use. The results obtained demonstrate that both He and Ar can improve the LIBS signal resolution of the hydrogen isotopes compared to air. However, using Ar has the additional advantage that the same procedure can also be used to detect He implanted in PFCs as a product of fusion reactions without any interference. Finally, the LIBS signal in an Ar atmosphere increases in terms of the signal-to-noise ratio (SNR), enabling the use of less energetic laser pulses to improve performance in depth profiling analyses.

20 January 2026 in Sensors
Verified
Journal Article
Open access
PDF file
violeta lazicvioleta lazic
violeta lazic
BSBiljana Stankov
Biljana Stankov
FAFabrizio Andreoli
Fabrizio Andreoli
MPMarco Pistilli
Marco Pistilli
IMIvano Menicucci
Ivano Menicucci
Pasqualino GaudioPasqualino Gaudio
Pasqualino Gaudio
In this work we report the results of analysis of the acoustic signal generated by the interaction of a nanosecond laser pulse (30 mJ, 1064 nm) with various residues placed on a silica wafer. The signal was captured by a unidirectional microphone placed 30 mm from the laser-generated plasma. The examined sample classes, other than the clean wafer, included particles from soils and rocks, carbonates, nitro precursors, ash, coal, smeared diesel, and particles of explosives. We tested three types of explosives, namely PETN, RDX, and HMX, having different origins. For the explosives, the acoustic signal showed a faster rise, larger amplitude, different width, and attenuation compared with the other sample classes. By subtracting the acoustic signal from the wafer at the same position, obtained after four cleaning laser pulses, the contribution of echoes was eliminated and true differences between the residue and substrate became evident. Through four different features in the subtracted signal, it was possible to classify explosives without the presence of false positives; the estimated limit of detection was 15 ng, 9.6 ng, and 18 ng for PETN, RDX, and HMX, respectively, where the mass was extrapolated from nano-printed samples and LIBS spectra acquired simultaneously. Furthermore, HMX was distinguished from the other two explosives in 90% of the cases; diesel and coal were also recognized. We also found that explosives deposited through wet transfer behaved as inert substances for the tested masses up to 30 ng.