Sovuthy Cheab

Dr. Sovuthy Cheab


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 September 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
SAShahid Muhammad Ali
Shahid Muhammad Ali
SCSovuthy Cheab
Sovuthy Cheab
Muhammad ImranMuhammad Imran
Muhammad Imran
SSSOCHEATRA SOEUNG
SOCHEATRA SOEUNG
Qammer AbbasiQammer Abbasi
Qammer Abbasi
Zuhairiah Zainal AbidinZuhairiah Zainal Abidin
Zuhairiah Zainal Abidin
The demand for wearable technologies has grown tremendously in recent years. Wearable antennas are used for various applications, in many cases within the context of wireless body area networks (WBAN). In WBAN, the presence of the human body poses a significant challenge to the wearable antennas. Specifically, such requirements are required to be considered on a priority basis in the wearable antennas, such as structural deformation, precision, and accuracy in fabrication methods and their size. Various researchers are active in this field and, accordingly, some significant progress has been achieved recently. This article attempts to critically review the wearable antennas especially in light of new materials and fabrication methods, and novel designs, such as miniaturized button antennas and miniaturized single and multi-band antennas, and their unique smart applications in WBAN. Finally, the conclusion has been drawn with respect to some future directions.

6 June 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MYMUHAMMAD SANI YAHYA
MUHAMMAD SANI YAHYA
SSSOCHEATRA SOEUNG
SOCHEATRA SOEUNG
NSNarinderjit Singh Sawaran Singh
Narinderjit Singh Sawaran Singh
ZYZainab Yunusa
Zainab Yunusa
FCFrancis Emmanuel Chinda
Francis Emmanuel Chinda
GAGhulam E Mustafa Abro
Ghulam E Mustafa Abro
In this study, a novel reconfigurable triple-band monopole antenna for LoRa IoT applications is fabricated on an FR-4 substrate. The proposed antenna is designed to function at three distinct LoRa frequency bands: 433 MHz, 868 MHz, and 915 MHz covering the LoRa bands in Europe, America, and Asia. The antenna is reconfigurable by using a PIN diode switching mechanism, which allows for the selection of the desired operating frequency band based on the state of the diodes. The antenna is designed using CST MWS® software 2019 and optimized for maximum gain, good radiation pattern and efficiency. The antenna with a total dimension of 80 mm × 50 mm × 0.6 mm (0.12λ0×0.07λ0 × 0.001λ0 at 433 MHz) has a gain of 2 dBi, 1.9 dBi, and 1.9 dBi at 433 MHz, 868 MHz, and 915 MHz, respectively, with an omnidirectional H-plane radiation pattern and a radiation efficiency above 90% across the three frequency bands. The fabrication and measurement of the antenna have been carried out, and the results of simulation and measurements are compared. The agreement among the simulation and measurement results confirms the design’s accuracy and the antenna’s suitability for LoRa IoT applications, particularly in providing a compact, flexible, and energy efficient communication solution for different LoRa frequency bands.

22 April 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
SAShahid Muhammad Ali
Shahid Muhammad Ali
SCSovuthy Cheab
Sovuthy Cheab
Sima NoghanianSima Noghanian
Sima Noghanian
ZAZulfiqur Ali
Zulfiqur Ali
Qammer AbbasiQammer Abbasi
Qammer Abbasi
SSSOCHEATRA SOEUNG
SOCHEATRA SOEUNG
The human body is an extremely challenging environment for wearable antennas due to the complex antenna-body coupling effects. In this article, a compact flexible dual-band planar meander line monopole antenna (MMA) with a truncated ground plane made of multiple layers of standard off-the-shelf materials is evaluated to validate its performance when worn by different subjects to help the designers who are shaping future complex on-/off-body wireless devices. The antenna was fabricated, and the measured results agreed well with those from the simulations. As a reference, in free-space, the antenna provided omnidirectional radiation patterns (ORP), with a wide impedance bandwidth of 1282.4 (450.5) MHz with a maximum gain of 3.03 dBi (4.85 dBi) in the lower (upper) bands. The impedance bandwidth could reach up to 688.9 MHz (500.9 MHz) and 1261.7 MHz (524.2 MHz) with the gain of 3.80 dBi (4.67 dBi) and 3.00 dBi (4.55 dBi), respectively, on the human chest and arm. The stability in results shows that this flexible antenna is sufficiently robust against the variations introduced by the human body. A maximum measured shift of 0.5 and 100 MHz in the wide impedance matching and resonance frequency was observed in both bands, respectively, while an optimal gap between the antenna and human body was maintained. This stability of the working frequency provides robustness against various conditions including bending, movement, and relatively large fabrication tolerances.

20 March 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
SAShahid Muhammad Ali
Shahid Muhammad Ali
SCSovuthy Cheab
Sovuthy Cheab
Sima NoghanianSima Noghanian
Sima Noghanian
TSTale Saeidi
Tale Saeidi
MMMuhammad Faran Majeed
Muhammad Faran Majeed
Qammer AbbasiQammer Abbasi
Qammer Abbasi
A button sensor antenna for on-body monitoring in wireless body area network (WBAN) systems is presented. Due to the close coupling between the sensor antenna and the human body, it is highly challenging to design sensor antenna devices. In this paper, a mechanically robust system is proposed that integrates a dual-band button antenna with a wireless sensor module designed on a printed circuit board (PCB). The system features a small footprint and has good radiation characteristics and efficiency. This was fabricated, and the measured and simulated results are in good agreement. The design offers a wide range of omnidirectional radiation patterns in free space, with a reflection coefficient (S11) of −29.30 (−30.97) dB, a maximum gain of 1.75 (5.65) dBi, and radiation efficiency of 71.91 (92.51)% in the lower and upper bands, respectively. S11 reaches −23.07 (−27.07) dB and −30.76 (−31.12) dB, respectively, with a gain of 2.09 (6.70) dBi and 2.16 (5.67) dBi, and radiation efficiency of 65.12 (81.63)% and 75.00 (85.00)%, when located on the body for the lower and upper bands, respectively. The performance is minimally affected by bending, movement, and fabrication tolerances. The specific absorption rate (SAR) values are below the regulatory limitations for the spatial average over 1 g (1.6 W/Kg) and 10 g of tissues (2.0 W/Kg). For both indoor and outdoor conditions, experimental results of the range tests confirm the coverage of up to 40 m.

25 October 2022 in IEEE Access
Verified
Journal Article
Open access
SKSokha Khim
Sokha Khim
SCSovuthy Cheab
Sovuthy Cheab
SSSOCHEATRA SOEUNG
SOCHEATRA SOEUNG
GNGuan Shen Ng
Guan Shen Ng
In this article, Y-junction strip-line circulators are designed using an enhanced closed form solution consisting of unified key equations and a flowchart design, which serves as a direct procedure for designing a ferrite circulator. This design methodology is combined with a 3D EM simulation that allows for the calculation of the saturation magnetization, uniform biasing, and ferrite dimensions needed for a circulator to operate in both modes. In addition, the closed form can be used to calculate the Y-junction parameters and allow the matching network to be calculated and the uniform circulator biasing design ended. Our analysis starts with the ferrite calculation to ensure that it is uniformly biased magnetically, and this is followed by strip-line design, Y-junction matching, and biasing circuit design. Using full-wave electromagnetic (EM), HFSS and magnetostatic (MS), Maxwell3D simulations, several key design parameters such as the saturation magnetization, coupling angle, and various external permanent magnetic biases are investigated. To validate the proposed concept, two strip-line circulators are designed and fabricated for operation in wide-bandwidth and narrow-bandwidth applications. Good agreement is found between the simulated and experimental responses for the S-parameters of the circulators. We also present a semi-analytical analysis of the concept of breakdown, which enables calculation of the peak power and total thermal rise in the strip-line structure. The average power handling capability of a strip-line circulator is studied for the first time. The proposed closed form expressions can also be implemented in various ferrite circulators using different guiding technologies for millimeter-wave applications.

31 August 2023 in Radioengineering
Verified
Journal Article
Closed access
CNC. L. Ng
C. L. Ng
SSSOCHEATRA SOEUNG
SOCHEATRA SOEUNG
SCSovuthy Cheab
Sovuthy Cheab
KLK. Y. Leong
K. Y. Leong