Georgii Konoplev

Dr. Georgii Konoplev

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 January 2022 in Biomedicines
Verified
Journal Article
Open access
PDF file
GKGeorgii Konoplev
Georgii Konoplev
DADarina Agafonova
Darina Agafonova
LBLiubov Bakhchova
Liubov Bakhchova
NMNikolay Mukhin
Nikolay Mukhin
MKMarharyta Kurachkina
Marharyta Kurachkina
SHSören Hirsch
Sören Hirsch
Proteins in biological fluids (blood, urine, cerebrospinal fluid) are important biomarkers of various pathological conditions. Protein biomarkers detection and quantification have been proven to be an indispensable diagnostic tool in clinical practice. There is a growing tendency towards using portable diagnostic biosensor devices for point-of-care (POC) analysis based on microfluidic technology as an alternative to conventional laboratory protein assays. In contrast to universally accepted analytical methods involving protein labeling, label-free approaches often allow the development of biosensors with minimal requirements for sample preparation by omitting expensive labelling reagents. The aim of the present work is to review the variety of physical label-free techniques of protein detection and characterization which are suitable for application in micro-fluidic structures and analyze the technological and material aspects of label-free biosensors that implement these methods. The most widely used optical and impedance spectroscopy techniques: absorption, fluorescence, surface plasmon resonance, Raman scattering, and interferometry, as well as new trends in photonics are reviewed. The challenges of materials selection, surfaces tailoring in microfluidic structures, and enhancement of the sensitivity and miniaturization of biosensor systems are discussed. The review provides an overview for current advances and future trends in microfluidics integrated technologies for label-free protein biomarkers detection and discusses existing challenges and a way towards novel solutions.

15 October 2020 in Journal of Composites Science
Verified
Journal Article
Open access
PDF file
ASAlena Smirnova
Alena Smirnova
GKGeorgii Konoplev
Georgii Konoplev
NMNikolay Mukhin
Nikolay Mukhin
OSOksana Stepanova
Oksana Stepanova
USUlrike Steinmann
Ulrike Steinmann
Milk is a product that requires quality control at all stages of production: from the dairy farm, processing at the dairy plant to finished products. Milk is a complex multiphase polydisperse system, whose components not only determine the quality and price of raw milk, but also reflect the physiological state of the herd. Today’s production volumes and rates require simple, fast, cost-effective, and accurate analytical methods, and most manufacturers want to move away from methods that use reagents that increase analysis time and move to rapid analysis methods. The review presents methods for the rapid determination of the main components of milk, examines their advantages and disadvantages. Optical spectroscopy is a fast, non-destructive, precise, and reliable tool for determination of the main constituents and common adulterants in milk. While mid-infrared spectroscopy is a well-established off-line laboratory technique for the routine quality control of milk, near-infrared technologies provide relatively low-cost and robust solutions suitable for on-site and in-line applications on milking farms and dairy production facilities. Other techniques, discussed in this review, including Raman spectroscopy, atomic spectroscopy, molecular fluorescence spectroscopy, are also used for milk analysis but much less extensively. Acoustic methods are also suitable for non-destructive on-line analysis of milk. Acoustic characterization can provide information on fat content, particle size distribution of fat and proteins, changes in the biophysical properties of milk over time, the content of specific proteins and pollutants. The basic principles of ultrasonic techniques, including transmission, pulse-echo, interferometer, and microbalance approaches, are briefly described and milk parameters measured with their help, including frequency ranges and measurement accuracy, are given.

1 October 2018 in Technical Physics Letters
Verified
Journal Article
Closed access
PDF file
ASA. V. Sachenko
A. V. Sachenko
VKV. P. Kostylyov
V. P. Kostylyov
ABAlexander Bobyl
Alexander Bobyl
VVV. N. Vlasyuk
V. N. Vlasyuk
ISI. O. Sokolovskyi
I. O. Sokolovskyi
Mykhaylo EvstigneevMykhaylo Evstigneev
Mykhaylo Evstigneev
A theory is developed, which describes the experimental external quantum efficiency, EQE(λ) as a function of photon wavelength for structured Si-based solar cells. Short-circuit current density as a...

14 January 2023 in Chemosensors
Verified
Journal Article
Open access
PDF file
AKArtur Ivan Kuznetsov
Artur Ivan Kuznetsov
AFAleksandr Frorip
Aleksandr Frorip
ASAlar Sünter
Alar Sünter
NKNensi Kasvand
Nensi Kasvand
VKVadim Korsakov
Vadim Korsakov
NMNikolay Mukhin
Nikolay Mukhin
Fast protein and metabolite liquid chromatography (FPLMC) was introduced years ago to enable the easy separation of high-molecular compounds such as proteins from small molecules and the identification of the low-molecular substances. In this paper, the method is applied for the rapid evaluation of freshness and monitoring the aging of animal meat and fish. A novel chromatographic sensor was developed with a deep UV LED-based photometric detection unit (255–265 nm), an original flow cuvette and registration scheme; the processing of a chromatogram with the sensor takes approximately 15 min. Strict isochronism between the elution of ATP metabolites, mainly hypoxanthine (Hx) and inosine monophosphate (IMP), and the time of maturation of meat or fish, was discovered. A new freshness index H* = [Hx]/[IMP] was introduced, which is proportional to the instrumental delay time in the FPMLC chromatograms: the H* index < 0.5 indicates the presence of inosine monophosphate (IMP) and the high quality of the meat or fish. Reasonably strong correlations were revealed between data obtained by FPMLC and total volatile basic nitrogen TVB-N (for fish) or volatile fatty acids VFA (for meat) content. Moreover, putative nucleotide salvage and an increase in the concentration of IMP were observed in fish after heat treatment using the FPMLC sensor and NMR technique.

6 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
NMNikolay Mukhin
Nikolay Mukhin
GKGeorgii Konoplev
Georgii Konoplev
AOAleksandr Oseev
Aleksandr Oseev
MSMarc-Peter Schmidt
Marc-Peter Schmidt
OSOksana Stepanova
Oksana Stepanova
SHSören Hirsch
Sören Hirsch
Diagnostic devices for point-of-care (POC) urine analysis (urinalysis) based on microfluidic technology have been actively developing for several decades as an alternative to laboratory based biochemical assays. Urine proteins (albumin, immunoglobulins, uromodulin, haemoglobin etc.) are important biomarkers of various pathological conditions and should be selectively detected by urinalysis sensors. The challenge is a determination of different oligomeric forms of the same protein, e.g., uromodulin, which have similar bio-chemical affinity but different physical properties. For the selective detection of different types of proteins, we propose to use a shear bulk acoustic resonator sensor with an additional electrode on the upper part of the bioliquid-filled channel for protein electric field manipulation. It causes modulation of the protein concentration over time in the near-surface region of the acoustic sensor, that allows to distinguish proteins based on their differences in diffusion coefficients (or sizes) and zeta-potentials. Moreover, in order to improve the sensitivity to density, we propose to use structured sensor interface. A numerical study of this approach for the detection of proteins was carried out using the example of albumin, immunoglobulin, and oligomeric forms of uromodulin in model urine solutions. In this contribution we prove the proposed concept with numerical studies for the detection of albumin, immunoglobulin, and oligomeric forms of uromodulin in urine models.

13 December 2023 in Photonics
Verified
Journal Article
Open access
PDF file
MRMariya Romanovich
Mariya Romanovich
YLYevgeniy Levin
Yevgeniy Levin
AGAnastasia Gubina
Anastasia Gubina
ADAleksandr Degterev
Aleksandr Degterev
ILIvan Lamkin
Ivan Lamkin
DMDenis Maimistov
Denis Maimistov
Precise adaptation of the greenhouse lighting spectrum to basic photophysiological processes can effectively and directionally stimulate plant growth and development. The optimal spectrum depends on the plant species and the stage of development and could be assessed empirically. The aim of this study is to determine the LED illumination spectrum that provides a significant improvement in the growth rate and accumulation of biologically active compounds for basil plants (Ocimum basilicum L.) under hydroponic cultivation compared to more traditional lighting sources. The following light sources with various emission spectra were used: an LED lamp within a spectral range of 400–800 nm (B:G:R 15%:5%:80%); a high-pressure sodium lamp (HPS) (B:G:R 5%:45%:50%); a compact fluorescent lamp (B:G:R 20%:40%:40%); a grow LED strip (B:G:R 15%:40%:45%); a white LED lamp (B:G:R 30%:45%:25%); a customized LED lighting setup in color ratios 100%B, 75%B + 25%R, 50%B + 50%R, 25%B + 75%R, 100%R, and natural lighting. A photosynthetic photon flux density (PPFD) of 150 μmol∙m−2∙s−1 was provided with all the sources. It was demonstrated reliably that employing the LED strip as an illumination device gives a 112% increase in basil plant yield compared to the HPS; the transpiration coefficient for the LED strip is six times lower than for the HPS. The content of flavonoids in the basil aerial parts on the 30th, 50th, and 70th days of development is 3.2 times higher than for the HPS; the metabolite composition is also more uniform for LED strip lighting.