Nikolay Mukhin

Dr. Nikolay Mukhin

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 August 2019 in Sensors
Verified
Journal Article
Open access
PDF file
NMNikolay Mukhin
Nikolay Mukhin
MKMykhailo Kutia
Mykhailo Kutia
AOAleksandr Oseev
Aleksandr Oseev
USUlrike Steinmann
Ulrike Steinmann
Stefan PalisStefan Palis
Stefan Palis
Ralf LucklumRalf Lucklum
Ralf Lucklum
Periodic elastic composite structures attract great attention. They offer the ability to design artificial properties to advance the control over the propagation of elastic/acoustic waves. In previous work, we drew attention to composite periodic structures comprising liquids. It was shown that the transmission spectrum of the structure, specifically a well-isolated peak, follows the material properties of liquid constituent in a distinct manner. This idea was realized in several liquid sensor concepts that launched the field of phononic crystal liquid sensors. In this work we introduce a novel concept—narrow band solid-liquid composite arrangements. We demonstrate two different concepts to design narrow band structures, and show the results of theoretical studies and results of experimental investigations that confirm the theoretical predictions. This work extends prior studies in the field of phononic crystal liquid sensors with novel concepts and results that have a high potential in a field of volumetric liquid properties evaluation.

18 January 2022 in Biomedicines
Verified
Journal Article
Open access
PDF file
GKGeorgii Konoplev
Georgii Konoplev
DADarina Agafonova
Darina Agafonova
LBLiubov Bakhchova
Liubov Bakhchova
NMNikolay Mukhin
Nikolay Mukhin
MKMarharyta Kurachkina
Marharyta Kurachkina
SHSören Hirsch
Sören Hirsch
Proteins in biological fluids (blood, urine, cerebrospinal fluid) are important biomarkers of various pathological conditions. Protein biomarkers detection and quantification have been proven to be an indispensable diagnostic tool in clinical practice. There is a growing tendency towards using portable diagnostic biosensor devices for point-of-care (POC) analysis based on microfluidic technology as an alternative to conventional laboratory protein assays. In contrast to universally accepted analytical methods involving protein labeling, label-free approaches often allow the development of biosensors with minimal requirements for sample preparation by omitting expensive labelling reagents. The aim of the present work is to review the variety of physical label-free techniques of protein detection and characterization which are suitable for application in micro-fluidic structures and analyze the technological and material aspects of label-free biosensors that implement these methods. The most widely used optical and impedance spectroscopy techniques: absorption, fluorescence, surface plasmon resonance, Raman scattering, and interferometry, as well as new trends in photonics are reviewed. The challenges of materials selection, surfaces tailoring in microfluidic structures, and enhancement of the sensitivity and miniaturization of biosensor systems are discussed. The review provides an overview for current advances and future trends in microfluidics integrated technologies for label-free protein biomarkers detection and discusses existing challenges and a way towards novel solutions.

14 September 2021 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
AGA. Gueddida
A. Gueddida
YPYan Pennec
Yan Pennec
VZV. Zhang
V. Zhang
FLFrieder Lucklum
Frieder Lucklum
MVM. Vellekoop
M. Vellekoop
BRB. Djafari Rouhani
B. Djafari Rouhani
We propose the design of a tubular phononic crystal (TPC) for the purpose of sensing the physical properties of a liquid filling the hollow part of the tube. The TPC is constituted by a periodic repetition of washers along a hollow pipe with the advantage of avoiding any perturbation of a flowing fluid by any element inside the tube. Using finite element simulations, we demonstrate the existence of complete as well as polarization dependent bandgaps inside which one can design localized modes associated with defects. The most sensitive cavity to the liquid sound velocity is found to be constituted by a Fabry–Pérot (F–P) cavity. The signature of the cavity modes can be detected as peaks or dips in the transmission spectrum as well as at the external surface of the cavity. We study the dramatic effect of the liquid viscosity, more particularly shear viscosity, on these features and discuss the conditions for their practical observation. A TPC test sample made of a polymer is fabricated by means of 3D printing and characterized without the liquid by transmission measurements. The comparison with the simulations showed the necessity of considering the damping of the polymer whose effect on the transmission features is discussed. Our sensor design can find many applications at different scales in several systems transporting a fluid as microfluidic channels in micro- and nanotechnologies, syringes in medicine, or pipelines in civil engineering.

6 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
NMNikolay Mukhin
Nikolay Mukhin
MKMykhailo Kutia
Mykhailo Kutia
AAAlexander Aman
Alexander Aman
USUlrike Steinmann
Ulrike Steinmann
Ralf LucklumRalf Lucklum
Ralf Lucklum
We show new approaches to developing acoustic liquid sensors based on phononic crystals. The proposed phononic crystal integrates fluidic elements. A solid block with periodic cylindrical holes contains a defect—a liquid-filled cylindrical cavity. We pay attention to acoustic excitation and the readout of the axisymmetric cylindrical resonator eigenmode of the liquid-filled defect in the middle of the phononic crystal structure. This mode solves the challenge of mechanical energy losses due to liquid viscosity. We also analyze the coupling effects between oscillations of liquid and solid systems and consider coupling issues between piezoelectric transducers and the liquid-filled cavity resonator. The numerical simulation of the propagation of acoustic waves through the phononic crystal sensor was carried out in COMSOL Multiphysics Software. The phononic crystal was made of stainless steel with mechanically drilled holes and was fabricated for experimental verification. We show that a tuning of the solid–liquid vibrational modes coupling is the key to an enhanced level of sensitivity to liquid properties. Besides (homogeneous) water–propanol mixtures, experimental studies were carried out on (disperse) water–fuel emulsions.

13 July 2021 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
Ralf LucklumRalf Lucklum
Ralf Lucklum
NMNikolay Mukhin
Nikolay Mukhin
Mechanical resonators have a long tradition. We concentrate on new results with a sensor for liquid analytes, the phononic crystal (PnC) sensor. Here, the liquid analyte becomes the integral part of a phononic crystal. The liquid-filled cavity acts as a defect in an otherwise regular structure. The sensor probes the entire liquid volume. The primary sensor input value is the speed of sound in the liquid; the primary output parameter is a shift in the resonance frequency. We theoretically analyze 1D- and 2D-PnC sensors. An optimal relation of frequency shift and bandwidth of the resonance is the key to an enhanced sensitivity of the sensor to liquid analyte properties. We introduce a new 2D PnC sensor design concept: The sensor-specific feature is an analyte-filled point defect. This defect becomes the analyte-filled capillary in the real sensor. This is the step toward the integration of PnC and microfluidic components. Electromechanical transducers excite and detect longitudinal acoustic waves along the channel, not at the front ends of the capillary. The sensor-specific task of the 2D-PnC is the conversion of this longitudinal wave into the axisymmetric mode in the liquid-filled cavity. In contrast to other modes, this mode avoids shear displacement at the solid–liquid interface and thereby absorption of acoustic energy due to liquid shear viscosity. Experiments prove the correctness of our approach.

15 October 2020 in Journal of Composites Science
Verified
Journal Article
Open access
PDF file
ASAlena Smirnova
Alena Smirnova
GKGeorgii Konoplev
Georgii Konoplev
NMNikolay Mukhin
Nikolay Mukhin
OSOksana Stepanova
Oksana Stepanova
USUlrike Steinmann
Ulrike Steinmann
Milk is a product that requires quality control at all stages of production: from the dairy farm, processing at the dairy plant to finished products. Milk is a complex multiphase polydisperse system, whose components not only determine the quality and price of raw milk, but also reflect the physiological state of the herd. Today’s production volumes and rates require simple, fast, cost-effective, and accurate analytical methods, and most manufacturers want to move away from methods that use reagents that increase analysis time and move to rapid analysis methods. The review presents methods for the rapid determination of the main components of milk, examines their advantages and disadvantages. Optical spectroscopy is a fast, non-destructive, precise, and reliable tool for determination of the main constituents and common adulterants in milk. While mid-infrared spectroscopy is a well-established off-line laboratory technique for the routine quality control of milk, near-infrared technologies provide relatively low-cost and robust solutions suitable for on-site and in-line applications on milking farms and dairy production facilities. Other techniques, discussed in this review, including Raman spectroscopy, atomic spectroscopy, molecular fluorescence spectroscopy, are also used for milk analysis but much less extensively. Acoustic methods are also suitable for non-destructive on-line analysis of milk. Acoustic characterization can provide information on fat content, particle size distribution of fat and proteins, changes in the biophysical properties of milk over time, the content of specific proteins and pollutants. The basic principles of ultrasonic techniques, including transmission, pulse-echo, interferometer, and microbalance approaches, are briefly described and milk parameters measured with their help, including frequency ranges and measurement accuracy, are given.