Ulrike Steinmann

Ulrike Steinmann

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 August 2019 in Sensors
Verified
Journal Article
Open access
PDF file
NMNikolay Mukhin
Nikolay Mukhin
MKMykhailo Kutia
Mykhailo Kutia
AOAleksandr Oseev
Aleksandr Oseev
USUlrike Steinmann
Ulrike Steinmann
Stefan PalisStefan Palis
Stefan Palis
Ralf LucklumRalf Lucklum
Ralf Lucklum
Periodic elastic composite structures attract great attention. They offer the ability to design artificial properties to advance the control over the propagation of elastic/acoustic waves. In previous work, we drew attention to composite periodic structures comprising liquids. It was shown that the transmission spectrum of the structure, specifically a well-isolated peak, follows the material properties of liquid constituent in a distinct manner. This idea was realized in several liquid sensor concepts that launched the field of phononic crystal liquid sensors. In this work we introduce a novel concept—narrow band solid-liquid composite arrangements. We demonstrate two different concepts to design narrow band structures, and show the results of theoretical studies and results of experimental investigations that confirm the theoretical predictions. This work extends prior studies in the field of phononic crystal liquid sensors with novel concepts and results that have a high potential in a field of volumetric liquid properties evaluation.

6 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
NMNikolay Mukhin
Nikolay Mukhin
MKMykhailo Kutia
Mykhailo Kutia
AAAlexander Aman
Alexander Aman
USUlrike Steinmann
Ulrike Steinmann
Ralf LucklumRalf Lucklum
Ralf Lucklum
We show new approaches to developing acoustic liquid sensors based on phononic crystals. The proposed phononic crystal integrates fluidic elements. A solid block with periodic cylindrical holes contains a defect—a liquid-filled cylindrical cavity. We pay attention to acoustic excitation and the readout of the axisymmetric cylindrical resonator eigenmode of the liquid-filled defect in the middle of the phononic crystal structure. This mode solves the challenge of mechanical energy losses due to liquid viscosity. We also analyze the coupling effects between oscillations of liquid and solid systems and consider coupling issues between piezoelectric transducers and the liquid-filled cavity resonator. The numerical simulation of the propagation of acoustic waves through the phononic crystal sensor was carried out in COMSOL Multiphysics Software. The phononic crystal was made of stainless steel with mechanically drilled holes and was fabricated for experimental verification. We show that a tuning of the solid–liquid vibrational modes coupling is the key to an enhanced level of sensitivity to liquid properties. Besides (homogeneous) water–propanol mixtures, experimental studies were carried out on (disperse) water–fuel emulsions.

15 October 2020 in Journal of Composites Science
Verified
Journal Article
Open access
PDF file
ASAlena Smirnova
Alena Smirnova
GKGeorgii Konoplev
Georgii Konoplev
NMNikolay Mukhin
Nikolay Mukhin
OSOksana Stepanova
Oksana Stepanova
USUlrike Steinmann
Ulrike Steinmann
Milk is a product that requires quality control at all stages of production: from the dairy farm, processing at the dairy plant to finished products. Milk is a complex multiphase polydisperse system, whose components not only determine the quality and price of raw milk, but also reflect the physiological state of the herd. Today’s production volumes and rates require simple, fast, cost-effective, and accurate analytical methods, and most manufacturers want to move away from methods that use reagents that increase analysis time and move to rapid analysis methods. The review presents methods for the rapid determination of the main components of milk, examines their advantages and disadvantages. Optical spectroscopy is a fast, non-destructive, precise, and reliable tool for determination of the main constituents and common adulterants in milk. While mid-infrared spectroscopy is a well-established off-line laboratory technique for the routine quality control of milk, near-infrared technologies provide relatively low-cost and robust solutions suitable for on-site and in-line applications on milking farms and dairy production facilities. Other techniques, discussed in this review, including Raman spectroscopy, atomic spectroscopy, molecular fluorescence spectroscopy, are also used for milk analysis but much less extensively. Acoustic methods are also suitable for non-destructive on-line analysis of milk. Acoustic characterization can provide information on fat content, particle size distribution of fat and proteins, changes in the biophysical properties of milk over time, the content of specific proteins and pollutants. The basic principles of ultrasonic techniques, including transmission, pulse-echo, interferometer, and microbalance approaches, are briefly described and milk parameters measured with their help, including frequency ranges and measurement accuracy, are given.

1 March 2018 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
AOAleksandr Oseev
Aleksandr Oseev
NMNikolay Mukhin
Nikolay Mukhin
RLRalf Lucklum
Ralf Lucklum
MZMikhail Zubtsov
Mikhail Zubtsov
MSMarc-Peter Schmidt
Marc-Peter Schmidt
SHSoeren Hirsch
Soeren Hirsch

1 December 2014 in Powder Technology
Verified
Journal Article
Closed access
RWRobert Weser
Robert Weser
SWSebastian Woeckel
Sebastian Woeckel
BWBenno Wessely
Benno Wessely
USUlrike Steinmann
Ulrike Steinmann
FBFrank Babick
Frank Babick
MSMichael Stintz
Michael Stintz

10 July 2020 in Materials
Verified
Journal Article
Open access
PDF file
LBLiubov Bakhchova
Liubov Bakhchova
LJLinas Jonušauskas
Linas Jonušauskas
DADovilė Andrijec
Dovilė Andrijec
MKMarharyta Kurachkina
Marharyta Kurachkina
TBTomas Baravykas
Tomas Baravykas
USUlrike Steinmann
Ulrike Steinmann
Organ-on-a-chip devices are gaining popularity in medical research due to the possibility of performing extremely complex living-body-resembling research in vitro. For this reason, there is a substantial drive in developing technologies capable of producing such structures in a simple and, at the same time, flexible manner. One of the primary challenges in producing organ-on-chip devices from a manufacturing standpoint is the prevalence of layer-by-layer bonding techniques, which result in limitations relating to the applicable materials and geometries and limited repeatability. In this work, we present an improved approach, using three dimensional (3D) laser lithography for the direct integration of a functional part—the membrane—into a closed-channel system. We show that it allows the freely choice of the geometry of the membrane and its integration into a complete organ-on-a-chip system. Considerations relating to sample preparation, the writing process, and the final preparation for operation are given. Overall, we consider that the broader application of 3D laser lithography in organ-on-a-chip fabrication is the next logical step in this field’s evolution.