Zsófia Keresztes

Dr. Zsófia Keresztes

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 September 2020 in Metals
Verified
Journal Article
Open access
PDF file
AGAli Gharaibeh
Ali Gharaibeh
IFIlona Felhősi
Ilona Felhősi
ZKZsófia Keresztes
Zsófia Keresztes
GHGábor Harsányi
Gábor Harsányi
BIBalázs Illés
Balázs Illés
Bálint MedgyesBálint Medgyes
Bálint Medgyes
Tin–silver–copper (SAC) solder alloys are the most promising candidates to replace Sn–Pb solder alloys. However, their application is still facing several challenges; one example is the electrochemical corrosion behaviour, which imposes a risk to electronics reliability. Numerous investigations have been carried out to evaluate the corrosion performance of SAC lead-free alloys, regarding the effect of the corrosive environment, the different manufacturing technologies, the effect of fluxes, the metallic contents within the SAC alloys themselves, and the different alloying elements. In these studies, widely used electrochemical techniques are applied as accelerated corrosion tests, such as linear sweep voltammetry and electrochemical impedance spectroscopy. However, there is lack of studies that try to summarise the various corrosion results in terms of lead-free solder alloys including low-Ag and composite solders. This study aims to review these studies by showing the most important highlights regarding the corrosion processes and the possible future developments.

1 December 2018 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
LRLoránd Románszki
Loránd Románszki
MTMarek Tatarko
Marek Tatarko
MJMengchi Jiao
Mengchi Jiao
ZKZsófia Keresztes
Zsófia Keresztes
Tibor HianikTibor Hianik
Tibor Hianik
Michael ThompsonMichael Thompson
Michael Thompson

22 August 2022 in Materials Today Chemistry
Verified
Journal Article
Open access
KJK. Jakab
K. Jakab
JCJ. Csipor
J. Csipor
IUI. Ulbert
I. Ulbert
ZKZsófia Keresztes
Zsófia Keresztes
GMGábor Mészáros
Gábor Mészáros
GMG. Márton
G. Márton

7 September 2023 in Biomolecules
Verified
Journal Article
Open access
PDF file
KJKristóf Jakab
Kristóf Jakab
NMNikitas Melios
Nikitas Melios
George TsekenisGeorge Tsekenis
George Tsekenis
Abdul Shaban IbdewiAbdul Shaban Ibdewi
Abdul Shaban Ibdewi
VHViola Horvath
Viola Horvath
ZKZsófia Keresztes
Zsófia Keresztes
To date, numerous aptamer-based biosensing platforms have been developed for sensitive and selective monitoring of target analytes, relying on analyte-induced conformational changes in the aptamer for the quantification of the analyte and the conversion of the binding event into a measurable signal. Despite the impact of these conformational rearrangements on sensor performance, the influence of the environment on the structural conformations of aptamers has rarely been investigated, so the link between parameters directly influencing aptamer folding and the ability of the aptamer to bind to the target analyte remains elusive. Herein, the effect a number of variables have on an aptamer’s 3D structure was examined, including the pH of the buffering medium, as well as the anchoring of the aptamer on a solid support, with the use of two label-free techniques. Circular dichroism spectroscopy was utilized to study the conformation of an aptamer in solution along with any changes induced to it by the environment (analyte binding, pH, composition and ionic strength of the buffer solution), while quartz crystal microbalance with dissipation monitoring was employed to investigate the surface-bound aptamer’s behavior and performance. Analysis was performed on an aptamer against oxytetracycline, serving as a model system, representative of aptamers selected against small molecule analytes. The obtained results highlight the influence of the environment on the folding and thus analyte-binding capacity of an aptamer and emphasize the need to deploy appropriate surface functionalization protocols in sensor development as a means to minimize the steric obstructions and undesirable interactions of an aptamer with a surface onto which it is tethered.

11 November 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
LRLoránd Románszki
Loránd Románszki
Zoltan VargaZoltan Varga
Zoltan Varga
JMJudith Mihály
Judith Mihály
ZKZsófia Keresztes
Zsófia Keresztes
Michael ThompsonMichael Thompson
Michael Thompson
An electromagnetic piezoelectric acoustic sensor (EMPAS) was used to study the non-specific adsorption of human red blood cell-derived extracellular vesicle preparations. Vesicle storage history (temperature and duration) highly affected the obtained results: The signal change, namely the frequency decrease of the crystal measured at 20 °C, was negligibly small (<1 s−2) when the vesicle solutions had previously been stored at 4 °C, and was in the order of 10 s−2 when the vesicle solutions had been stored at −30 °C. Moreover, the rate of frequency decrease increased exponentially with the storage time at −30 °C. Upon a 4 °C storage period following the −30 °C storage period of the same sample, the measured frequency decrease dropped, suggesting a partial relaxation of the system. The results are explained by the disintegration of the vesicles triggered by the freeze–thaw cycle, likely due to the detachment of proteins from the vesicle surface as was proved by size-exclusion chromatography. Surface modification of the sensor crystal provided the possibility of signal enhancement, as the maximum rate of the frequency change for the same vesicle concentrations was higher on hydrophobic, octadecyl trichlorosilane–modified quartz than on hydrophilic, bare quartz. The EMPAS signal has been associated with the amount of detached proteins, which in turn is proportional to the originating vesicle concentration.

23 March 2021 in Chemosensors
Verified
Journal Article
Open access
PDF file
GMGábor Mészáros
Gábor Mészáros
SASanaz Akbarzadeh
Sanaz Akbarzadeh
Brian De La FranierBrian De La Franier
Brian De La Franier
ZKZsófia Keresztes
Zsófia Keresztes
Michael ThompsonMichael Thompson
Michael Thompson
The ultra-high frequency EMPAS (electromagnetic piezoelectric acoustic sensor) device is composed of an electrode-less quartz disc in which shear oscillation is induced by an AC-powered magnetic coil located 30 μm below the substrate. This configuration allows the instigation of high acoustic harmonics (in the region of 49th–53rd), with the resulting enhanced analytical sensitivity for biosensor purposes compared to the conventional thickness-shear mode device. In this paper, we introduce significant improvements to the operation of the system with respect to sensing applications. This includes a new interface program and the capability to measure the acoustic quality factor not available in the prototype version. The enhanced configuration is subject to testing through biosensor detection of surface adsorption of biological macromolecules, which include β-casein, and a gelsolin-actin complex.