Eran Zenziper

Dr. Eran Zenziper

Tel Aviv University, Sackler Faculty of Medicine, School of Dental Medicine, Ramat Aviv, Tel Aviv, Israel

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 March 2016 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Closed access
PDF file
RKRoni Kolerman
Roni Kolerman
JNJoseph Nissan
Joseph Nissan
ARArkadi Rahmanov
Arkadi Rahmanov
EZEran Zenziper
Eran Zenziper
SSShimshon Slutzkey
Shimshon Slutzkey
HTHaim Tal
Haim Tal

20 October 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ASasaf shely
asaf shely
DLDiva Lugassy
Diva Lugassy
ORofir rosner
ofir rosner
EZEran Zenziper
Eran Zenziper
Joseph NissanJoseph Nissan
Joseph Nissan
GBGil Ben-izhack
Gil Ben-izhack
Background: The purpose of this in vitro study was to compare the inter-implant distance, inter-implant axis, and intra-implant axis of three implants in a straight line by using a laboratory scanner (LBS) versus an intra-oral scanner (IOS) with two different intra-oral scan bodies (ISBs). Methods: A 3D model was printed with internal hex implant analogs of three implants in positions 15#, 16#, and 17#. Two standard intra-oral scan bodies (ISBs) were used: MIS ISB (two-piece titanium) and Zirkonzhan ISB (two-piece titanium). Both ISBs were scanned using 7 Series dental wings (LBS) and 30 times using Primescan (IOS). For each scan, a stereolithography (STL) file was created and a comparison between all the scans was performed through superimposition of the STL files by using 3D analysis software (PolyWorks® 2020; InnovMetric, Québec, QC, Canada). A Kolmogorov–Smirnov test was performed followed by a Mann–Whitney test (p < 0.05). Results: The change in inter-implant distance for the MIS ISB was significantly lower compared to the ZZ (p < 0.05). The change in intra-implant angle was significantly lower for the ZZ ISB compared to MIS (p < 0.05). The changes in inter-implant angle between the mesial and middle and between the middle and distal were significantly lower for MIS compared to ZZ in contrast to mesial to distal, which was significantly higher (p < 0.05). Conclusions: Both ISBs showed differences in all the parameters between the LBS and the IOS. The geometry of the scan abutment had an impact on the inter-implant distance as the changes in the inter-implant distance were significantly lower for the MIS ISB. The changes in the intra-implant angle were significantly lower for the ZZ ISB. There is a need for further research examining the influence of geometry, material, and scan abutment parts on the trueness.

9 October 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SNSarit Adriana Naishlos
Sarit Adriana Naishlos
EZEran Zenziper
Eran Zenziper
HZHelena Zelikman
Helena Zelikman
Joseph NissanJoseph Nissan
Joseph Nissan
SMShaked Mizrahi
Shaked Mizrahi
LCLiat Chaushu
Liat Chaushu
Background: Various conditions may lead to bony deficiency in the anterior maxilla. The present study evaluated esthetic (PES—pink esthetic score and WES—white esthetic score) results after augmentation of the anterior atrophic maxilla using cancellous bone-block allograft followed by implant placement and late (conventional) loading. Methods: Cohort study that included 33 patients with missing teeth in the upper anterior region characterized by extensive bone loss. Allogeneic cancellous bone-blocks were used for augmentation. Six months later, a dental implant was inserted. After a waiting time of an additional six-months, implant exposure and reconstruction were performed. The mean follow-up period was 62.93 ± 17.37 months (range 19–82 months). Results: The mean value of PES/WES was 17.8 ± 2.78. All patients had a PES/WES value above 12 (threshold value defined as clinically acceptable esthetics). The mean value of PES was 9.0 ± 1.79 and the mean value of WES was 8.8 ±1.84. Conclusions: Bone augmentation of the anterior atrophic maxilla using cancellous block-allograft and late loading supports achievement of a predictable esthetic result with long-term stability of soft and hard tissues around implant-supported reconstructions.

21 October 2020 in Materials
Verified
Journal Article
Open access
PDF file
Joseph NissanJoseph Nissan
Joseph Nissan
ORofir rosner
ofir rosner
GRGal Rosen
Gal Rosen
SNSarit Adriana Naishlos
Sarit Adriana Naishlos
EZEran Zenziper
Eran Zenziper
LCLiat Chaushu
Liat Chaushu
Impression technique is one of the factors affecting restoration fit accuracy, which is a major aspect influencing its survival. The purpose of this study is to compare, in vivo, the effect of two commonly used Vinyl Polysiloxane (VPS) impression techniques on the metal framework fitting of fixed partial dentures. Ninety-two consecutive patients, diagnosed as partially edentulous, treated by fixed partial denture restorations, participated in the study. Group 1-impressions (n = 44) were subjected to the 1-step technique, while group 2 impressions (n = 48) were subjected the 2-step technique. Three accuracy assessment common methods: probe, tactile sense and radiographic test, were used to validate the clinical fit of the metal framework. Misfit was defined as even one test failure. Twenty-one (22.8%) out of 92 metal frameworks exhibited metal frameworks misfit, whereas the other 71 (77.2%) were found to be accurate. Group 1 presented significantly (p = 0.04) more metal frameworks misfit, 14/44 (31.8%) vs. 7/48 (14.6%). Restoration location (maxilla vs. mandible) had no statistically significant impact on the results (p = 0.461). The use of the VPS putty/wash 2-step impression technique is recommended to improve the clinical fit of fixed partial denture restorations.

18 April 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
GBGil Ben-izhack
Gil Ben-izhack
ORofir rosner
ofir rosner
EZEran Zenziper
Eran Zenziper
Joseph NissanJoseph Nissan
Joseph Nissan
Reema HosaryReema Hosary
Reema Hosary
ASasaf shely
asaf shely
Background: In this study, we aimed to compare the effects of conventional and digital impressions on several parameters (inter-implant distance, intra-implant distance, inter-implant axis, and intra-implant axis) of three implants in curved lines and straight lines by using a laboratory scanner (LBS) versus an intra-oral scanner (IOS). Methods: Two 3D models were fabricated using a printer, each model with three internal hex implants analogues at the positions of 15#,16#,17# (straight line) and 12#,13#,14# (curved line). Standard intra-oral scan bodies (ISBs) were used, and the two models were scanned using 7 Series dental wings (LBS, reference model), followed by ten scans with Primescan (digital method). Standard Tessellation Language (STL) files were created. Five polyether impressions were taken from each model (straight and curved), and gypsum type 4 models were poured; each model was scanned five times to create a total of 25 STL files for each group (conventional method). The comparison between all the STL files (conventional and digital) was made by superimposition of the STL files on the STL reference model laboratory file using a 3D analyzing software. A Kolmogorov–Smirnov test was performed, followed by Mann–Whitney tests and Wilcoxon signed-rank tests. (p < 0.05). Results: For the conventional method, the mean errors were significantly higher for the curved line model (12–14) compared to the straight line model (15–17) for most parameters (p < 0.05). For the digital method, the mean errors were significantly higher for the curved-line model (12–14) compared to the straight line model (15–17) in half of the parameters (p < 0.05). Within the curved line model (12–14) and the straight line model (15–17), the mean errors between the conventional method and the digital method were not significant for most variables. Conclusions: The difference between curved lines and straight lines has an impact on the mean error of the conventional method. Both methods are reliable for straight and curved lines in partially dentate situations.

18 December 2024 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
ASAlon Shadur
Alon Shadur
Joseph NissanJoseph Nissan
Joseph Nissan
DLDiva Lugassy
Diva Lugassy
AUAriana Umansky
Ariana Umansky
EZEran Zenziper
Eran Zenziper
GBGil Ben-izhack
Gil Ben-izhack
Objective: In everyday dentistry, lithium disilicate is a valid option for single-fix partial dentures, and this material crystallization process is available with two protocols: long and short. This study’s aim was to assess the effects of these two different crystallization protocols, long and short, on the marginal gap of lithium disilicate single crowns. Methods: A total of 24 abutment plastic teeth were scanned using an intra-oral scanner. For each plastic tooth, an identical pair of lithium disilicate crowns was milled (a total of 48 crowns) by a four-axis machine. Each paired sample was categorized into two groups: long crystallization (24 crowns) and short crystallization (24 crowns). To assess precision, each unit’s marginal gap (including abutments and crowns) was meticulously measured at four specified regions using a scanning electron microscope. A Kolmogorov–Smirnov test performed on the study variables indicated a normal distribution (p > 0.05), and it was followed by independent t-tests (α = 0.05). Results: For the long crystallization group, the mean total marginal gap values were 42.91 ± 9.67 μm, and for the short crystallization group, the values were 43.25 ± 8.14 μm, with no significant difference between the groups (p = 0.894). In addition, no significant differences were found between the groups regarding the mean marginal gap measurements for all four surfaces (distal (p = 0.310), mesial (p = 0.732), palatal (p = 0.655), and buccal (p = 0.535)). Conclusions: Both the long and short crystallization methods used for lithium disilicate single crowns demonstrated marginal gap values of less than 120 μm, which are within the clinically acceptable range, with no significant differences across any parameters between the two groups. Regarding the marginal gap value, it is recommended to use the short crystallization protocol as it is more time-efficient.